Publications

Results 26–40 of 40
Skip to search filters

Results with a 32-element dual mode imager

Mascarenhas, Nicholas M.; Cooper, Robert L.; Marleau, Peter M.; Mrowka, Stanley M.; Brennan, James S.

We present advances with a 32 element scalable, segmented dual mode imager. Scaling up the number of cells results in a 1.4 increase in efficiency over a system we deployed last year. Variable plane separation has been incorporated which further improves the efficiency of the detector. By using 20 cm diameter cells we demonstrate that we could increase sensitivity by a factor of 6. We further demonstrate gamma ray imaging in from Compton scattering. This feature allows for powerful dual mode imaging. Selected results are presented that demonstrate these new capabilities.

More Details

Applying the neutron scatter camera to treaty verification and warhead monitoring

Mascarenhas, Nicholas M.; Cooper, Robert L.; Mrowka, Stanley M.; Brennan, James S.; Marleau, Peter M.

The neutron scatter camera was originally developed for a range of SNM detection applications. We are now exploring the feasibility of applications in treaty verification and warhead monitoring using experimentation, maximum likelihood estimation method (MLEM), detector optimization, and MCNP-PoliMi simulations.

More Details

Results with a 32 element dual mode imager

Brennan, James S.; Cooper, Robert L.; Mrowka, Stanley M.; Marleau, Peter M.

We present advances with a 32 element scalable, segmented dual mode imager. Scaling up the number of cells results in a 1.4 increase in efficiency over a system we deployed last year. Variable plane separation has been incorporated which further improves the efficiency of the detector. By using 20 cm diameter cells we demonstrate that we could increase sensitivity by a factor of 6. We further demonstrate gamma ray imaging in from Compton scattering. This feature allows for powerful dual mode imaging. Selected results are presented that demonstrate these new capabilities.

More Details

Final LDRD report : advanced plastic scintillators for neutron detection

O'Bryan, Gregory O.; Mrowka, Stanley M.; Mascarenhas, Nicholas M.

This report summarizes the results of a one-year, feasibility-scale LDRD project that was conducted with the goal of developing new plastic scintillators capable of pulse shape discrimination (PSD) for neutron detection. Copolymers composed of matrix materials such as poly(methyl methacrylate) (PMMA) and blocks containing trans-stilbene (tSB) as the scintillator component were prepared and tested for gamma/neutron response. Block copolymer synthesis utilizing tSBMA proved unsuccessful so random copolymers containing up to 30% tSB were prepared. These copolymers were found to function as scintillators upon exposure to gamma radiation; however, they did not exhibit PSD when exposed to a neutron source. This project, while falling short of its ultimate goal, demonstrated the possible utility of single-component, undoped plastics as scintillators for applications that do not require PSD.

More Details

A novel dual mode neutron-gamma imager

Mascarenhas, Nicholas M.; Brennan, James S.; Cooper, Robert L.; Mrowka, Stanley M.; Marleau, Peter M.

The Neutron Scatter Camera (NSC) can image fission sources and determine their energy spectra at distances of tens of meters and through significant thicknesses of intervening materials in relatively short times [1]. We recently completed a 32 element scatter camera and will present recent advances made with this instrument. A novel capability for the scatter camera is dual mode imaging. In normal neutron imaging mode we identify and image neutron events using pulse shape discrimination (PSD) and time of flight in liquid scintillator. Similarly gamma rays are identified from Compton scatter in the front and rear planes for our segmented detector. Rather than reject these events, we show it is possible to construct a gamma-ray image by running the analysis in a 'Compton mode'. Instead of calculating the scattering angle by the kinematics of elastic scatters as is appropriate for neutron events, it can be found by the kinematics of Compton scatters. Our scatter camera has not been optimized as a Compton gamma-ray imager but is found to work reasonably. We studied imaging performance using a Cs137 source. We find that we are able to image the gamma source with reasonable fidelity. We are able to determine gamma energy after some reasonable assumptions. We will detail the various algorithms we have developed for gamma image reconstruction. We will outline areas for improvement, include additional results and compare neutron and gamma mode imaging.

More Details

Results with the neutron scatter camera

Brennan, James S.; Krenz, Kevin D.; Marleau, Peter M.; Mrowka, Stanley M.; Mascarenhas, Nicholas M.

We describe the design, calibration, and measurements made with the neutron scatter camera. Neutron scatter camera design allows for the determination of the direction and energy of incident neutrons by measuring the position, recoil energy, and time-of-flight (TOF) between elastic scatters in two liquid scintillator cells. The detector response and sensitive energy range (0.5-10 MeV) has been determined by detailed calibrations using a {sup 252}Cf neutron source over its field of view (FOV). We present results from several recent deployments. In a laboratory study we detected a {sup 252}Cf neutron source at a stand off distance of 30 m. A hidden neutron source was detected inside a large ocean tanker. We measured the integral flux density, differential energy distribution and angular distribution of cosmic neutron background in the fission energy range 0.5-10 MeV at Alameda, CA (sea level), Livermore, CA (174 m), Albuquerque, NM (1615 m) and Fenton Hill, NM (2630 m). The neutron backgrounds are relatively low, and non-isotropic. The camera has been ruggedized, deployed to various locations and has performed various measurements successfully. Our results show fast neutron imaging could be a useful tool for the detection of special nuclear material (SNM).

More Details

Towards above-ground antineutrino detectors for cooperative monitoring : background radiation studies

Mrowka, Stanley M.; Reyna, David R.; Krenz, Kevin D.; Sadler, Lorraine E.

We describe an assembly of detectors that quantifies the background radiation present at potential above ground antineutrino detector development and deployment sites. Antineutrino detectors show great promise for safeguard applications in directly detecting the total fission rate as well as the change in fissile content of nuclear power reactors. One major technical challenge that this safeguard application must overcome is the ability to distinguish signals from antineutrinos originating in the reactor core from noise due to background radiation created by terrestrial and cosmogenic sources. To date, existing detectors increase their ability to distinguish antineutrino signals by being surrounded with significant shielding and being placed underground. For the safeguard's agency, this is less than optimal, increasing the overall size and limiting the placement of this system. For antineutrino monitoring to be a widely deployable solution, we must understand the backgrounds found above ground at nuclear power plants that can mimic the antineutrino signal so that these backgrounds can be easily identified, separated, and subtracted rather than shielded. The design, construction, calibration, and results from the deployment of these background detectors at a variety of sites will be presented.

More Details

A measurement of the flux, angular distribution and energy spectra of cosmic ray induced neutrons at fission energies

IEEE Nuclear Science Symposium Conference Record

Mascarenhas, Nicholas; Brennan, James S.; Krenz, Kevin D.; Marleau, Peter M.; Mrowka, Stanley M.

When searching for SNM simply designing a better detector to optimize the signal S from the source is not enough. It is important to know the background B to maximize S/N, where N is the noise in B. Cosmic rays are a dominant source of neutron background. It is therefore important to know their flux, angular and energy distribution. Over the last 50 years work has been done to study cosmic ray neutrons and their variation. The full hemispherical neutron flux is usually quoted at a certain altitude (e.g. Altitude = 0 meters above sea level, pressure = 1033 g/cm2) and geomagnetic rigidity (e.g. GMR = 1.2GV). Neutron fluxes at other locations are scaled from the sea level data using a well determined prescription. However, there is a lack in knowledge of the angular dependence of the neutron flux at sea level. The angular dependence is important for two reasons; first many detectors have an efficiency that changes with the direction of the incident neutron. Second none of the measurements to date have determined how the flux changes with angle, their data must be modeled to estimate the full hemispherical flux. In this paper we present the cosmic neutron background flux measured by a neutron scatter camera in the energy range 0.2-10MeV. Our measurements are in agreement with the best fit to past data. We present for the 1st time the neutron zenith angle dependence at fission energies which is observed to be a function of the form cos 2.7⊖. ©2007 IEEE.

More Details
Results 26–40 of 40
Results 26–40 of 40