Effect of Time Delay Asymmetries in Power System Damping Control
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
IEEE Power & Energy Society General Meeting (Online)
Abstract not provided.
IEEE Power & Energy Society General Meeting (Online)
Abstract not provided.
To demonstrate and validate the performance of the wide-are a damping control system, the project plans to conduct closed-loop tests on the PDCI in summer/fall 2016. A test plan details the open and closed loop tests to be conducted on the P DCI using the wide-area damping control system. To ensure the appropriate level of preparedness, simulations were performed in order to predict and evaluate any possible unsafe operations before hardware experiments are attempted. This report contains the result s from these simulations using the power system dynamics software PSLF (Power System Load Flow, trademark of GE). The simulations use the WECC (Western Electricity Coordinating Council) 2016 light summer and heavy summer base cases.
Conference Record of the IEEE Photovoltaic Specialists Conference
The goal of this effort was to assess the effect of high penetration solar deployment on the small signal stability of the western North American power system (wNAPS). Small signal stability is concerned with the system response to small disturbances, where the system is operating in a linear region. The study area consisted of the region governed by the Western Electricity Coordinating Council (WECC). General Electric's Positive Sequence Load Flow software (PSLF®) was employed to simulate the power system. A resistive brake insertion was employed to stimulate the system. The data was then analyzed in MATLAB® using subspace methods (Eigensystem Realization Algorithm). Two different WECC base cases were analyzed: 2022 light spring and 2016 heavy summer. Each base case was also modified to increase the percentage of wind and solar. In order to keep power flows the same, the modified cases replaced conventional generation with renewable generation. The replacements were performed on a regional basis so that solar and wind were placed in suitable locations. The main finding was that increased renewable penetration increases the frequency of inter-area modes, with minimal impact on damping. The slight increase in mode frequency was consistent with the loss of inertia as conventional generation is replaced with wind and solar. Then, distributed control of renewable generation was assessed as a potential mitigation, along with an analysis of the impact of communications latency on the distributed control algorithms.
IEEE Power and Energy Society General Meeting
The uncontrolled intermittent availability of renewable energy sources makes integration of such devices into today's grid a challenge. Thus, it is imperative that dynamic simulation tools used to analyze power system performance are able to support systems with high amounts of photovoltaic (PV) generation. Additionally, simulation durations expanding beyond minutes into hours must be supported. This paper aims to identify the path forward for dynamic simulation tools to accommodate these needs by characterizing the properties of power systems (with high PV penetration), analyzing how these properties affect dynamic simulation software, and offering solutions for potential problems. In particular, the system eigenvalue configuration of representative power system models is examined and how this configuration influences numerical integration scheme selection is discussed.
IEEE Power and Energy Society General Meeting
This paper describes a control scheme to mitigate inter-area oscillations through active damping. The control system uses real-time phasor measurement unit (PMU) feedback to construct a commanded power signal to modulate the flow of real power over the Pacific DC Intertie (PDCI) located in the western North American Power System (wNAPS). A hardware prototype was constructed to implement the control scheme. To ensure safe and reliable performance, the project integrates a supervisory system to ensure the controller is operating as expected at all times. A suite of supervisory functions are implemented across three hardware platforms. If any controller mal-function is detected, the supervisory system promptly disables the controller through a bumpless transfer method. This paper presents a detailed description of the control scheme, simulation results, the bumpless transfer method, and a redundancy and diversity method in the selection of PMU signals for feedback. This paper also describes in detail the supervisory system implemented to ensure safe and reliable damping performance of the real-time wide area damping controller.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
The uncontrolled intermittent availability of renewable energy sources makes integration of such devices into today's grid a challenge. Thus, it is imperative that dynamic simulation tools used to analyze power system performance are able to support systems with high amounts of photovoltaic (PV) generation. Additionally, simulation durations expanding beyond minutes into hours must be supported. This report aims to identify the path forward for dynamic simulation tools to accom- modate these needs by characterizing the properties of power systems (with high PV penetration), analyzing how these properties affect dynamic simulation software, and offering solutions for po- tential problems. We present a study of fixed time step, explicit numerical integration schemes that may be more suitable for these goals, based on identified requirements for simulating high PV penetration systems. We also present the alternative of variable time step integration. To help determine the characteristics of systems with high PV generation, we performed small signal sta- bility studies and time domain simulations of two representative systems. Along with feedback from stakeholders and vendors, we identify the current gaps in power system modeling including fast and slow dynamics and propose a new simulation framework to improve our ability to model and simulate longer-term dynamics.
This project aimed to identify the path forward for dynamic simulation tools to accommodate these needs by characterizing the properties of power systems (with high PV penetration), analyzing how these properties affect dynamic simulation software, and offering solutions for potential problems.
Abstract not provided.
Abstract not provided.
Abstract not provided.
IEEE Power and Energy Society General Meeting
Electromechanical oscillations often limit transmission capacity in the western North American Power System (termed the wNAPS). Recent research and development has focused on employing large-scale damping controls via wide-area feedback. Such an approach is made possible by the recent installation of a wide-area real-time measurement system based upon Phasor Measurement Unit (PMU) technology. One potential large-scale damping approach is based on energy storage devices. Such an approach has considerable promise for damping oscillations. This paper considers the placement of such devices within the wNAPS system. We explore combining energy storage devices with HVDC modulation of the Pacific DC Intertie (PDCI). We include eigenanalysis of a reduced-order wNAPS system, detailed analysis of a basic two-area dynamic system, and full-order transient simulations. We conclude that the optimal energy storage location is in the area with the lower inertia.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.