Publications

Results 76–91 of 91
Skip to search filters

Fish 'N' chips - A single cell genomic analyzer for the human microbiome

14th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2010, MicroTAS 2010

Meagher, Robert M.; Liu, Peng L.; Light, Yooli K.; Patel, K.D.; Perroud, T.D.; Singh, Anup K.

Uncultivable microorganisms likely play significant roles in the ecology within the human body, with subtle but important implications for human health. Focusing on the oral microbiome, we are developing a processor for targeted isolation of individual microbial cells, facilitating whole-genome analysis without the need for isolation of pure cultures. The processor consists of three microfluidic modules: identification based on 16S rRNA fluorescence in situ hybridization (FISH), fluorescence-based sorting, and encapsulation of individual selected cells into small droplets for whole-genome amplification. We present here a technique for performing microscale FISH and flow cytometry, as a prelude to single cell sorting.

More Details

Electrophoretic concentration of DNA at nanoporous polymer membranes for separations and diagnostics

Meagher, Robert M.; Thaitrong, Numrin T.; Singh, Anup K.

We report on the use of thin ({approx}30 micron) photopatterned polymer membranes for on-line preconcentration of single- or double-stranded DNA samples prior to electrophoretic analysis. Shaped UV laser light is used to quickly ({approx}10 seconds) polymerize a highly crosslinked polyacrylamide plug. By applying an electric field across the membrane, DNA from a dilute sample can be concentrated into a narrow zone (<100 micron wide) at the outside edge of the membrane. The field at the membrane can then be reversed, allowing the narrow plug to be cleanly injected into a separation channel filled with a sieving polymer for analysis. Concentration factors >100 are possible, increasing the sensitivity of analysis for dilute samples. We have fabricated both neutral membranes (purely size-based exclusion) as well as anionic membranes (size and charge exclusion), and characterized the rate of preconcentration as well as the efficiency of injection from both types of membrane, for DNA, ranging from a 20 base ssDNA oligonucleotide to >14 kbp dsDNA. We have also investigated the effects of concentration polarization on device performance for the charged membrane. Advantages of the membrane preconcentration approach include the simplicity of device fabrication and operation, and the generic (non-sequence specific) nature of DNA capture, which is useful for complex or poorly characterized samples where a specific capture sequence is not present. The membrane preconcentration approach is well suited to simple single-level etch glass chips, with no need for patterned electrodes, integrated heaters, valves, or other elements requiring more complex chip fabrication. Additionally, the ability to concentrate multiple charged analytes into a narrow zone enables a variety of assay functionalities, including enzyme-based and hybridization-based analyses.

More Details

Chip-based in situ hybridization for identification of bacteria from the human microbiome

Meagher, Robert M.; Liu, Peng L.; Light, Yooli K.; Singh, Anup K.

The emerging field of metagenomics seeks to assess the genetic diversity of complex mixed populations of bacteria, such as those found at different sites within the human body. A single person's mouth typically harbors up to 100 bacterial species, while surveys of many people have found more than 700 different species, of which {approx}50% have never been cultivated. In typical metagenomics studies, the cells themselves are destroyed in the process of gathering sequence information, and thus the connection between genotype and phenotype is lost. A great deal of sequence information may be generated, but it is impossible to assign any given sequence to a specific cell. We seek non-destructive, culture-independent means of gathering sequence information from selected individual cells from mixed populations. As a first step, we have developed a microfluidic device for concentrating and specifically labeling bacteria from a mixed population. Bacteria are electrophoretically concentrated against a photopolymerized membrane element, and then incubated with a specific fluorescent label, which can include antibodies as well as specific or non-specific nucleic acid stains. Unbound stain is washed away, and the labeled bacteria are released from the membrane. The stained cells can then be observed via epifluorescence microscopy, or counted via flow cytometry. We have tested our device with three representative bacteria from the human microbiome: E. coli (gut, Gram-negative), Lactobacillus acidophilus (mouth, Gram-positive), and Streptococcus mutans (mouth, Gram-positive), with results comparable to off-chip labeling techniques.

More Details

FISH 'N' Chips : a single cell genomic analyzer for the human microbiome

Meagher, Robert M.; Patel, Kamlesh P.; Light, Yooli K.; Liu, Peng L.; Singh, Anup K.

Uncultivable microorganisms likely play significant roles in the ecology within the human body, with subtle but important implications for human health. Focusing on the oral microbiome, we are developing a processor for targeted isolation of individual microbial cells, facilitating whole-genome analysis without the need for isolation of pure cultures. The processor consists of three microfluidic modules: identification based on 16S rRNA fluorescence in situ hybridization (FISH), fluorescence-based sorting, and encapsulation of individual selected cells into small droplets for whole genome amplification. We present here a technique for performing microscale FISH and flow cytometry, as a prelude to single cell sorting.

More Details

Biomolecular transport and separation in nanotubular networks

Sasaki, Darryl Y.; Wang, Julia W.; Hayden, Carl C.; Stachowiak, Jeanne C.; Branda, Steven B.; Bachand, George B.; Meagher, Robert M.; Stevens, Mark J.; Robinson, David R.; Zendejas, Frank Z.

Cell membranes are dynamic substrates that achieve a diverse array of functions through multi-scale reconfigurations. We explore the morphological changes that occur upon protein interaction to model membrane systems that induce deformation of their planar structure to yield nanotube assemblies. In the two examples shown in this report we will describe the use of membrane adhesion and particle trajectory to form lipid nanotubes via mechanical stretching, and protein adsorption onto domains and the induction of membrane curvature through steric pressure. Through this work the relationship between membrane bending rigidity, protein affinity, and line tension of phase separated structures were examined and their relationship in biological membranes explored.

More Details

Host suppression and bioinformatics for sequence-based characterization of unknown pathogens

Misra, Milind; Patel, Kamlesh P.; Kaiser, Julia N.; Meagher, Robert M.; Branda, Steven B.; Schoeniger, Joseph S.

Bioweapons and emerging infectious diseases pose formidable and growing threats to our national security. Rapid advances in biotechnology and the increasing efficiency of global transportation networks virtually guarantee that the United States will face potentially devastating infectious disease outbreaks caused by novel ('unknown') pathogens either intentionally or accidentally introduced into the population. Unfortunately, our nation's biodefense and public health infrastructure is primarily designed to handle previously characterized ('known') pathogens. While modern DNA assays can identify known pathogens quickly, identifying unknown pathogens currently depends upon slow, classical microbiological methods of isolation and culture that can take weeks to produce actionable information. In many scenarios that delay would be costly, in terms of casualties and economic damage; indeed, it can mean the difference between a manageable public health incident and a full-blown epidemic. To close this gap in our nation's biodefense capability, we will develop, validate, and optimize a system to extract nucleic acids from unknown pathogens present in clinical samples drawn from infected patients. This system will extract nucleic acids from a clinical sample, amplify pathogen and specific host response nucleic acid sequences. These sequences will then be suitable for ultra-high-throughput sequencing (UHTS) carried out by a third party. The data generated from UHTS will then be processed through a new data assimilation and Bioinformatic analysis pipeline that will allow us to characterize an unknown pathogen in hours to days instead of weeks to months. Our methods will require no a priori knowledge of the pathogen, and no isolation or culturing; therefore it will circumvent many of the major roadblocks confronting a clinical microbiologist or virologist when presented with an unknown or engineered pathogen.

More Details

Selective extraction of recombinant proteins by multiple-affinity two-phase partitioning in microchannels

12th International Conference on Miniaturized Systems for Chemistry and Life Sciences - The Proceedings of MicroTAS 2008 Conference

Meagher, Robert M.; Light, Yooli K.; Singh, Anup K.

We have demonstrated purification of proteins in a simple aqueous two-phase extraction process in a microfluidic device. The laminar flows inherent to microchannels allows us to perform a binary split of a complex cell lysate sample, in an open channel with no chromatography support and no moving parts. This mild process allows recovery of functional proteins with a modest increase in purity. Aromatic-rich fusion tags are used to drive partitioning of enzymes in a generic PEG-salt two-phase system. Addition of affinity ligands to the PEG phase allows us to exploit other popular fusion tags, such as polyhistidine tags and GST-tags. © 2008 CBMS.

More Details

Multi-Spectral Detection of Microfluidic Separation Products

Hayden, Carl C.; Meagher, Robert M.

The objectives of this project were to develop a new scientific tool for studies of chemical processes at the single molecule level, and to provide enhanced capabilities for multiplexed, ultrasensitive separations and immunoassays. We have combined microfluidic separation techniques with our newly developed technology for spectrally and temporally resolved detection of single molecules. The detection of individual molecules can reveal fluctuations in molecular conformations, which are obscured in ensemble measurements, and allows detailed studies of reaction kinetics such as ligand or antibody binding. Detection near the single molecule level also enables the use of correlation techniques to extract information, such as diffusion rates, from the fluorescence signal. The micro-fluidic technology offers unprecedented control of the chemical environment and flow conditions, and affords the unique opportunity to study biomolecules without immobilization. For analytical separations, the fluorescence lifetime and spectral resolution of the detection makes it possible to use multiple parameters for identification of separation products to improve the certainty of identification. We have successfully developed a system that can measure fluorescence spectra, lifetimes and diffusion constants of the components of mixtures separated in a microfluidic electrophoresis chip.

More Details
Results 76–91 of 91