Publications

Results 101–109 of 109
Skip to search filters

Silicon carbide tritium permeation barrier for steel structural components

Buchenauer, D.A.; Kolasinski, Robert K.; Youchison, Dennis L.; Garde, J.; Holschuh, Thomas V.

Chemical vapor deposited (CVD) silicon carbide (SiC) has superior resistance to tritium permeation even after irradiation. Prior work has shown Ultrametfoam to be forgiving when bonded to substrates with large CTE differences. The technical objectives are: (1) Evaluate foams of vanadium, niobium and molybdenum metals and SiC for CTE mitigation between a dense SiC barrier and steel structure; (2) Thermostructural modeling of SiC TPB/Ultramet foam/ferritic steel architecture; (3) Evaluate deuterium permeation of chemical vapor deposited (CVD) SiC; (4) D testing involved construction of a new higher temperature (> 1000 C) permeation testing system and development of improved sealing techniques; (5) Fabricate prototype tube similar to that shown with dimensions of 7cm {theta} and 35cm long; and (6) Tritium and hermeticity testing of prototype tube.

More Details

Uranium for hydrogen storage applications : a materials science perspective

Kolasinski, Robert K.; Shugard, Andrew D.; Tewell, Craig R.; Cowgill, D.F.

Under appropriate conditions, uranium will form a hydride phase when exposed to molecular hydrogen. This makes it quite valuable for a variety of applications within the nuclear industry, particularly as a storage medium for tritium. However, some aspects of the U+H system have been characterized much less extensively than other common metal hydrides (particularly Pd+H), likely due to radiological concerns associated with handling. To assess the present understanding, we review the existing literature database for the uranium hydride system in this report and identify gaps in the existing knowledge. Four major areas are emphasized: {sup 3}He release from uranium tritides, the effects of surface contamination on H uptake, the kinetics of the hydride phase formation, and the thermal desorption properties. Our review of these areas is then used to outline potential avenues of future research.

More Details

Plasma-materials interaction results at Sandia National Laboratories

Kolasinski, Robert K.; Buchenauer, D.A.; Cowgill, D.F.; Karnesky, Richard A.; Whaley, Josh A.; Wampler, William R.

Overview of Plasma Materials Interaction (PMI) activities are: (1) Hydrogen diffusion and trapping in metals - (a) Growth of hydrogen precipitates in tungsten PFCs, (b) Temperature dependence of deuterium retention at displacement damage, (c) D retention in W at elevated temperatures; (2) Permeation - (a) Gas driven permeation results for W/Mo/SiC, (b) Plasma-driven permeation test stand for TPE; and (3) Surface studies - (a) H-sensor development, (b) Adsorption of oxygen and hydrogen on beryllium surfaces.

More Details

The impact of specific surface area on the retention of deuterium in carbon fiber composite materials

Fusion Engineering and Design

Kolasinski, Robert K.; Umstadter, K.R.; Sharpe, J.P.; Causey, Rion A.; Pawelko, R.J.; Whaley, Josh A.; Buchenauer, D.A.; Shimada, M.

In this study, the PISCES-A linear plasma instrument has been used to characterize retention in several carbon fiber composites in order to better understand the factors which lead to elevated retention levels in these materials. The PISCES instrument is capable of subjecting materials to intense fluxes (up to 1022 m-2 s-1) of low energy (150 eV) D+ ions, producing conditions similar to those encountered by plasma facing components in a fusion reactor. In this investigation, three CFCs (fabricated with different manufacturing processes) are compared with the N11 composite used in the Tore Supra reactor. The specific surface areas for these materials were within the range of 0.14-0.55 m2/g. The plasma bombardment conditions were adjusted to provide doses on the order of 1025-1026 m-2 at a sample temperature of 200 °C. After removal from PISCES-A, the amount of D retained in the sample surface was determined via thermal desorption spectroscopy. The measured retention showed a strong correlation with the type of material used and the corresponding BET surface area. By using a CFC with a lower internal porosity, one could expect a reduction in retention by a factor of 5 or more. © 2008 Elsevier B.V.

More Details
Results 101–109 of 109
Results 101–109 of 109