Publications

Results 51–67 of 67
Skip to search filters

Ground water and snow sensor based on directional detection of cosmogenic neutrons

Griffin, Patrick J.; Marleau, Peter M.

A fast neutron detector is being developed to measure the cosmic ray neutron flux in order to measure soil moisture. Soil that is saturated with water has an enhanced ability to moderate fast neutrons, removing them from the backscatter spectrum. The detector is a two-element, liquid scintillator detector. The choice of liquid scintillator allows rejection of gamma background contamination from the desired neutron signal. This enhances the ability to reconstruct the energy and direction of a coincident neutron event. The ability to image on an event-by-event basis allows the detector to selectively scan the neutron flux as a function of distance from the detector. Calibrations, simulations, and optimization have been completed to understand the detector response to neutron sources at variable distances and directions. This has been applied to laboratory background measurements in preparation for outdoor field tests.

More Details

Development of a silicon calorimeter for dosimetry applications in a water-moderated reactor

ASTM Special Technical Publication

Luker, Spencer M.; Griffin, Patrick J.; Depriest, Kendall D.; King, Donald B.; Naranjo, Gerald E.; Suo-Anttila, Ahti J.; Kellner, Ned

High fidelity active dosimetry in the mixed neutron/gamma field of a research reactor is a very complex issue. For passive dosimetry applications, the use of activation foils addresses the neutron environment while the use of low neutron response CaF2:Mn thermoluminescent dosimeters (TLDs) addresses the gamma environment. While radiation-hardened diamond photoconducting detectors (PCD) have been developed that provide a very precise fast response (picosecond) dosimeter and can provide a time-dependent profile for the radiation environment, the mixed field response of the PCD is still uncertain and this interferes with the calibration of the PCD response. In order to address the research reactor experimenter's need for a dosimeter that reports silicon dose and dose rate at a test location during a pulsed reactor operation, a silicon calorimeter has been developed. This dosimeter can be used by itself to provide a dose in rad(Si) up to a point in a reactor pulsed operation, or, in conjunction with the diamond PCD, to provide a dose rate. This paper reports on the development, testing, and validation of this silicon calorimeter for applications in water-moderated research reactors. Copyright © 2006 by ASTM International.

More Details

Criteria for the selection of dosimetry cross sections

Griffin, Patrick J.; Griffin, Patrick J.

This paper defines a process for selecting dosimetry-quality cross sections. The recommended cross-section evaluation depends on screening high-quality evaluations with quantified uncertainties, down-selecting based on comparison to experiments in standard neutron fields, and consistency checking in reference neutron fields. This procedure is illustrated for the {sup 23}Na(n,{gamma}){sup 24}Na reaction.

More Details

Neutron contribution to CaF2:Mn thermoluminescent dosimeter response in mixed (n/y) field environments

Proposed for publication in IEEE Transactions on Nuclear Science.

Depriest, Kendall D.; Depriest, Kendall D.; Griffin, Patrick J.

Thermoluminescent dosimeters (TLDs), particularly CaF{sub 2}:Mn, are often used as photon dosimeters in mixed (n/{gamma}) field environments. In these mixed field environments, it is desirable to separate the photon response of a dosimeter from the neutron response. For passive dosimeters that measure an integral response, such as TLDs, the separation of the two components must be performed by postexperiment analysis because the TLD reading system cannot distinguish between photon- and neutron-produced response. Using a model of an aluminum-equilibrated TLD-400 (CaF{sub 2}:Mn) chip, a systematic effort has been made to analytically determine the various components that contribute to the neutron response of a TLD reading. The calculations were performed for five measured reactor neutron spectra and one theoretical thermal neutron spectrum. The five measured reactor spectra all have experimental values for aluminum-equilibrated TLD-400 chips. Calculations were used to determine the percentage of the total TLD response produced by neutron interactions in the TLD and aluminum equilibrator. These calculations will aid the Sandia National Laboratories-Radiation Metrology Laboratory (SNL-RML) in the interpretation of the uncertainty for TLD dosimetry measurements in the mixed field environments produced by SNL reactor facilities.

More Details
Results 51–67 of 67
Results 51–67 of 67