Publications

Results 51–57 of 57
Skip to search filters

Multi-depth Measurement of Fast Neutrons

Marleau, Peter M.; Gerling, Mark D.; Sweany, Melinda; Cabrera-Palmer, Belkis C.; Brennan, James S.

A spallation based multiplicity detector has been constructed and deployed to the Kimballton Underground Research Facility to measure the cosmogenic fast neutron flux anti-coincident from the initiating muon. Two of the three planned measurements have been completed ( ,,, 380 and , -- , 600 m.w.e) with sufficient statistics. The third measurement at level 14 (-4450 m.w.e.) is currently being performed. Current results at - , 600 m.w.e. compare favourably to the one previous measurement at 550 m.w.e. For neutron energies between 100 and 200 MeV measurements at , -- , 380 m.w.e. produce fluxes between 1e -8 and 7e -9 n/cm 2 /s/MeV and at , - , 600 m.w.e. measurements produce fluxes between 7e -9 and 1e- 11 n/cm2 /s/MeV.

More Details

Bubble masks for time-encoded imaging of fast neutrons

Brubaker, Erik B.; Brennan, James S.; Marleau, Peter M.; Steele, John T.; Sweany, Melinda; Throckmorton, Daniel J.

Time-encoded imaging is an approach to directional radiation detection that is being developed at SNL with a focus on fast neutron directional detection. In this technique, a time modulation of a detected neutron signal is inducedtypically, a moving mask that attenuates neutrons with a time structure that depends on the source position. An important challenge in time-encoded imaging is to develop high-resolution two-dimensional imaging capabilities; building a mechanically moving high-resolution mask presents challenges both theoretical and technical. We have investigated an alternative to mechanical masks that replaces the solid mask with a liquid such as mineral oil. Instead of fixed blocks of solid material that move in pre-defined patterns, the oil is contained in tubing structures, and carefully introduced air gapsbubblespropagate through the tubing, generating moving patterns of oil mask elements and air apertures. Compared to current moving-mask techniques, the bubble mask is simple, since mechanical motion is replaced by gravity-driven bubble propagation; it is flexible, since arbitrary bubble patterns can be generated by a software-controlled valve actuator; and it is potentially high performance, since the tubing and bubble size can be tuned for high-resolution imaging requirements. We have built and tested various single-tube mask elements, and will present results on bubble introduction and propagation as a function of tubing size and cross-sectional shape; real-time bubble position tracking; neutron source imaging tests; and reconstruction techniques demonstrated on simple test data as well as a simulated full detector system.

More Details

Bubble masks for time-encoded imaging of fast neutrons

IEEE Nuclear Science Symposium Conference Record

Brennan, James S.; Brubaker, Erik B.; Nowack, Aaron; Steele, John T.; Sweany, Melinda; Throckmorton, Daniel J.

Time-encoded imaging is an approach to directional radiation detection that is being developed at SNL with a focus on fast neutron directional detection. In this technique, a time modulation of a detected neutron signal is induced - typically, a moving mask that attenuates neutrons with a time structure that depends on the source position. An important challenge in time-encoded imaging is to develop high-resolution two-dimensional imaging capabilities; building a mechanically moving high-resolution mask presents challenges both theoretical and technical. We have investigated an alternative to mechanical masks that replaces the solid mask with a liquid such as mineral oil. Instead of fixed blocks of solid material that move in predefined patterns, the oil is contained in tubing structures, and carefully introduced air gaps - bubbles - propagate through the tubing, generating moving patterns of oil mask elements and air apertures. Compared to current moving-mask techniques, the bubble mask is simple, since mechanical motion is replaced by gravity-driven bubble propagation; it is flexible, since arbitrary bubble patterns can be generated by a software-controlled valve actuator; and it is potentially high performance, since the tubing and bubble size can be tuned for high-resolution imaging requirements. We have built and tested various single-tube mask elements, and will present results on bubble introduction and propagation for different tube sizes and cross-sectional shapes; real-time bubble position tracking; neutron source imaging tests; and reconstruction techniques demonstrated on simple test data as well as a simulated full detector system. © 2013 IEEE.

More Details
Results 51–57 of 57
Results 51–57 of 57