Publications

Results 151–175 of 195
Skip to search filters

Differential B-dot and D-dot monitors for current and voltage measurements on a 20-MA 3-MV pulsed-power accelerator

Proposed for publication in Physical Review Special Topics - Accelerators and Beams.

Stygar, William A.; Savage, Mark E.; Speas, Christopher S.; Struve, Kenneth W.; Donovan, Guy L.; Lee, James R.; Leeper, Ramon J.; Leifeste, Gordon T.; Mills, Jerry A.; Rochau, G.A.; Rochau, Gary E.

We have developed a system of differential-output monitors that diagnose current and voltage in the vacuum section of a 20-MA 3-MV pulsed-power accelerator. The system includes 62 gauges: 3 current and 6 voltage monitors that are fielded on each of the accelerator's 4 vacuum-insulator stacks, 6 current monitors on each of the accelerator's 4 outer magnetically insulated transmission lines (MITLs), and 2 current monitors on the accelerator's inner MITL. The inner-MITL monitors are located 6 cm from the axis of the load. Each of the stack and outer-MITL current monitors comprises two separate B-dot sensors, each of which consists of four 3-mm-diameter wire loops wound in series. The two sensors are separately located within adjacent cavities machined out of a single piece of copper. The high electrical conductivity of copper minimizes penetration of magnetic flux into the cavity walls, which minimizes changes in the sensitivity of the sensors on the 100-ns time scale of the accelerator's power pulse. A model of flux penetration has been developed and is used to correct (to first order) the B-dot signals for the penetration that does occur. The two sensors are designed to produce signals with opposite polarities; hence, each current monitor may be regarded as a single detector with differential outputs. Common-mode-noise rejection is achieved by combining these signals in a 50-{Omega} balun. The signal cables that connect the B-dot monitors to the balun are chosen to provide reasonable bandwidth and acceptable levels of Compton drive in the bremsstrahlung field of the accelerator. A single 50-{omega} cable transmits the output signal of each balun to a double-wall screen room, where the signals are attenuated, digitized (0.5-ns/sample), numerically compensated for cable losses, and numerically integrated. By contrast, each inner-MITL current monitor contains only a single B-dot sensor. These monitors are fielded in opposite-polarity pairs. The two signals from a pair are not combined in a balun; they are instead numerically processed for common-mode-noise rejection after digitization. All the current monitors are calibrated on a 76-cm-diameter axisymmetric radial transmission line that is driven by a 10-kA current pulse. The reference current is measured by a current-viewing resistor (CVR). The stack voltage monitors are also differential-output gauges, consisting of one 1.8-cm-diameter D-dot sensor and one null sensor. Hence, each voltage monitor is also a differential detector with two output signals, processed as described above. The voltage monitors are calibrated in situ at 1.5 MV on dedicated accelerator shots with a short-circuit load. Faraday's law of induction is used to generate the reference voltage: currents are obtained from calibrated outer-MITL B-dot monitors, and inductances from the system geometry. In this way, both current and voltage measurements are traceable to a single CVR. Dependable and consistent measurements are thus obtained with this system of calibrated diagnostics. On accelerator shots that deliver 22 MA to a low-impedance z-pinch load, the peak lineal current densities at the stack, outer-MITL, and inner-MITL monitor locations are 0.5, 1, and 58 MA/m, respectively. On such shots the peak currents measured at these three locations agree to within 1%.

More Details

Transient electromagnetic modeling of the ZR accelerator water convolute and stack

Digest of Technical Papers-IEEE International Pulsed Power Conference

Pasik, Michael F.; Coats, Rebecca S.; Johnson, William Arthur.; Elizondo-Decanini, Juan M.; Pointon, Timothy D.; Turner, C.D.; Bohnhoff, William J.; Lehr, J.M.; Savage, Mark E.

The ZR accelerator is a refurbishment of Sandia National Laboratories Z accelerator [1]. The ZR accelerator components were designed using electrostatic and circuit modeling tools. Transient electromagnetic modeling has played a complementary role in the analysis of ZR components [2]. In this paper we describe a 3D transient electromagnetic analysis of the ZR water convolute and stack using edge-based finite element techniques. © 2005 IEEE.

More Details

Passive mitigation of load debris in a magnetically insulated transmission line

Digest of Technical Papers-IEEE International Pulsed Power Conference

Savage, Mark E.; Pointon, Timothy D.; Seidel, David B.; Mendel, Clifford W.; Wagoner, Timothy C.; Romero, Dustin H.; Wakeland, Peter E.

The Z driver at Sandia National Laboratories delivers one to two megajoules of electromagnetic energy inside its ∼10 cm radius final feed in 100 ns. The high current (∼20 MA) at small diameter produces magnetic pressures well above yield strengths for metals. The metal conductors stay in place due to inertia long enough to deliver current to the load. Within milliseconds however, fragments of metal escape the load region at high velocity. Much of the hardware and diagnostics inside the vacuum chamber is protected from this debris by blast shields with small view ports, and fast-closing valves. The water-vacuum insulator requires different protection because the transmission line debris shield should not significantly raise the inductance or perturb the self-magnetically insulated electron flow. This report shows calculations and results from a design intended to protect the insulator assembly. © 2005 IEEE.

More Details

Initial planning for interferometry measurements on triggered plasma opening switch source

Digest of Technical Papers-IEEE International Pulsed Power Conference

Lynn, A.G.; Jackson, Daniel P.; Gilmore, M.A.; Savage, Mark E.; Sharpe, R.A.

The Triggered Plasma Opening Switch (TPOS) at SNL is a unique device that exploits the high conductivity and low mass properties of plasma. The TPOS's objective is to take the initial ∼0.8MA (∼250ns rise time) storage inductor current and deliver ∼0.5MA at ∼2.4MV (∼10ns rise time) to a load of ∼5-10Ω. Configuration advantages include low current jitter and resistive voltage drop, power gain, and minimization of trigger input power as the result of using two stages in series. This two-stage design is novel and is the first to demonstrate operation of magnetically triggered stages. Study of TPOS characteristics is in progress via an offline interferometer diagnostic; specifically, a laser interferometer will be used to make density measurements of the source plasma. It is thought that the gross plasma source density is ∼1014 cm-3, but details of the spatial structure and temporal evolution have not previously been studied. In order to better understand switch operation, these details are essential. Presently two interferometer systems are planned for testing: a temporary 1 μm system for initial plasma characterization, and a 10.6 mu;m laser system for routine use. We will start with a single chord measurement then upgrade to a multi-chord system. Future plans involve varying plasma source parameters, such as magnetic field strength and plasma fill time, in order to understand the density dependence on these parameters. Improved knowledge of the plasma source density behavior should allow for improved switch operation. © 2005 IEEE.

More Details

Bulk breakdown in rexolite for non-uniform field geometries and single polarity pulses

Digest of Technical Papers-IEEE International Pulsed Power Conference

Stoltzfus, Brian S.; Savage, Mark E.

Although there is much written in regards to voltage breakdown of polymeric insulators under AC and DC conditions, much less is written involving Rexolite® (1422) [1], non-uniform field geometries, and impulse conditions. Yet, in order to design optimized pulsed power systems with some desired degree of reliability, understanding the behavior of this type of insulating system is needed. Specifically, Sandia National Laboratory's ZR project, which will use anode plugs in the vacuum stack (thus increasing the electrical stress in the Rexolite insulators), needs to be able to estimate the reliability of these vacuum stack insulators [2]. In an effort to estimate the insulator's lifetime small scale testing is in progress. Nine samples have been tested so far and at least ten more will be tested. Results from the current testing suggest that the Rexolite "ages" from pulse to pulse, that there is some volume dependence on breakdown strength, and that the electrode-vacuum-insulator interface has an affect on the insulator lifetime. ©2005 IEEE.

More Details

Copy of An overview of pulse compression and power flow in the upgraded Z pulsed power driver

Savage, Mark E.; Maenchen, John E.; McDaniel, Dillon H.; Pasik, Michael F.; Pointon, Timothy D.; Owen, Albert C.; Seidel, David B.; Stoltzfus, Brian S.; Struve, Kenneth W.; Warne, Larry K.; Bennett, Lawrence F.; Woodworth, Joseph R.; Bliss, David E.; Clark, Waylon T.; Coats, Rebecca S.; Elizondo-Decanini, Juan M.; LeChien, Keith R.; Harjes, Henry C.; Lehr, J.M.

Abstract not provided.

Fundamental science investigations to develop a 6-MV laser triggered gas switch for ZR: first annual report

Maenchen, John E.; Savage, Mark E.; Struve, Kenneth W.; Woodworth, Joseph R.; Lehr, J.M.; Warne, Larry K.; Bliss, David E.; Jorgenson, Roy E.; LeChien, Keith R.; McKee, George R.; Pasik, Michael F.; Rosenthal, Stephen E.

In October 2005, an intensive three-year Laser Triggered Gas Switch (LTGS) development program was initiated to investigate and solve observed performance and reliability issues with the LTGS for ZR. The approach taken has been one of mission-focused research: to revisit and reassess the design, to establish a fundamental understanding of LTGS operation and failure modes, and to test evolving operational hypotheses. This effort is aimed toward deploying an initial switch for ZR in 2007, on supporting rolling upgrades to ZR as the technology can be developed, and to prepare with scientific understanding for the even higher voltage switches anticipated needed for future high-yield accelerators. The ZR LTGS was identified as a potential area of concern quite early, but since initial assessments performed on a simplified Switch Test Bed (STB) at 5 MV showed 300-shot lifetimes on multiple switch builds, this component was judged acceptable. When the Z{sub 20} engineering module was brought online in October 2003 frequent flashovers of the plastic switch envelope were observed at the increased stresses required to compensate for the programmatically increased ZR load inductance. As of October 2006, there have been 1423 Z{sub 20} shots assessing a variety of LTGS designs. Numerous incremental and fundamental switch design modifications have been investigated. As we continue to investigate the LTGS, the basic science of plastic surface tracking, laser triggering, cascade breakdown, and optics degradation remain high-priority mission-focused research topics. Significant progress has been made and, while the switch does not yet achieve design requirements, we are on the path to develop successively better switches for rolling upgrade improvements to ZR. This report summarizes the work performed in FY 2006 by the large team. A high-level summary is followed by detailed individual topical reports.

More Details
Results 151–175 of 195
Results 151–175 of 195