Publications

Results 126–150 of 195
Skip to search filters

Expected result of firing an ICE load on Z without vacuum

Struve, Kenneth W.; Lemke, Raymond W.; Savage, Mark E.

In addressing the issue of the determining the hazard categorization of the Z Accelerator of doing Special Nuclear Material (SNM) experiments the question arose as to whether the machine could be fired with its central vacuum chamber open, thus providing a path for airborne release of SNM materials. In this report we summarize calculations that show that we could only expect a maximum current of 460 kA into such a load in a long-pulse mode, which will be used for the SNM experiments, and 750 kA in a short-pulse mode, which is not useful for these experiments. We also investigated the effect of the current for both cases and found that for neither case is the current high enough to either melt or vaporize these loads, with a melt threshold of 1.6 MA. Therefore, a necessary condition to melt, vaporize, or otherwise disperse SNM material is that a vacuum must exist in the Z vacuum chamber. Thus the vacuum chamber serves as a passive feature that prevents any airborne release during the shot, regardless of whatever containment may be in place.

More Details

Low impedance z-pinch drivers without post-hole convolute current adders

Savage, Mark E.

Present-day pulsed-power systems operating in the terawatt regime typically use post-hole convolute current adders to operate at sufficiently low impedance. These adders necessarily involve magnetic nulls that connect the positive and negative electrodes. The resultant loss of magnetic insulation results in electron losses in the vicinity of the nulls that can severely limit the efficiency of the delivery of the system's energy to a load. In this report, we describe an alternate transformer-based approach to obtaining low impedance. The transformer consists of coils whose windings are in parallel rather than in series, and does not suffer from the presence of magnetic nulls. By varying the pitch of the coils windings, the current multiplication ratio can be varied, leading to a more versatile driver. The coupling efficiency of the transformer, its behavior in the presence of electron flow, and its mechanical strength are issues that need to be addressed to evaluate the potential of transformer-based current multiplication as a viable alternative to conventional current adder technology.

More Details

High reliability low jitter 80 kV pulse generator

Proposed for publication in Physical Review: Special Topics on Accelerators and Beams.

Savage, Mark E.; Stoltzfus, Brian S.

Switching can be considered to be the essence of pulsed power. Time accurate switch/trigger systems with low inductance are useful in many applications. This article describes a unique switch geometry coupled with a low-inductance capacitive energy store. The system provides a fast-rising high voltage pulse into a low impedance load. It can be challenging to generate high voltage (more than 50 kilovolts) into impedances less than 10 {Omega}, from a low voltage control signal with a fast rise time and high temporal accuracy. The required power amplification is large, and is usually accomplished with multiple stages. The multiple stages can adversely affect the temporal accuracy and the reliability of the system. In the present application, a highly reliable and low jitter trigger generator was required for the Z pulsed-power facility [M. E. Savage, L. F. Bennett, D. E. Bliss, W. T. Clark, R. S. Coats,J. M. Elizondo, K. R. LeChien, H. C. Harjes, J. M. Lehr, J. E. Maenchen, D. H. McDaniel, M. F. Pasik, T. D. Pointon, A. C. Owen, D. B. Seidel, D. L. Smith, B. S. Stoltzfus, K.W. Struve, W.A. Stygar, L.K. Warne, and J. R. Woodworth, 2007 IEEE Pulsed Power Conference, Albuquerque, NM (IEEE, Piscataway, NJ, 2007), p. 979]. The large investment in each Z experiment demands low prefire probability and low jitter simultaneously. The system described here is based on a 100 kV DC-charged high-pressure spark gap, triggered with an ultraviolet laser. The system uses a single optical path for simultaneously triggering two parallel switches, allowing lower inductance and electrode erosion with a simple optical system. Performance of the system includes 6 ns output rise time into 5.6 {Omega}, 550 ps one-sigma jitter measured from the 5 V trigger to the high voltage output, and misfire probability less than 10{sup -4}. The design of the system and some key measurements will be shown in the paper. We will discuss the design goals related to high reliability and low jitter. While reliability is usually important, and is coupled with jitter, reliability is seldom given more than a qualitative analysis (if any at all). We will show how reliability of the system was calculated, and results of a jitter-reliability tradeoff study. We will describe the behavior of sulfur hexafluoride as the insulating gas in the mildly nonuniform field geometry at pressures of 300 to 500 kPa. We will show the resistance of the arc channels, and show the performance comparisons with normal two-channel operation, and single channel operation.

More Details

Shaping the output pulse of a linear-transformer-driver module

Proposed for publication in Physical Review Special Topics: Accelerators and Beams.

Stygar, William A.; Stoltzfus, Brian S.; Woodworth, Joseph R.; Fowler, William E.; LeChien, Keith R.; Long, Finis W.; Mazarakis, Michael G.; McKee, George R.; Mckenney, John M.; Savage, Mark E.

We demonstrate that a wide variety of current-pulse shapes can be generated using a linear-transformer-driver (LTD) module that drives an internal water-insulated transmission line. The shapes are produced by varying the timing and initial charge voltage of each of the module's cavities. The LTD-driven accelerator architecture outlined in [Phys. Rev. ST Accel. Beams 10, 030401 (2007)] provides additional pulse-shaping flexibility by allowing the modules that drive the accelerator to be triggered at different times. The module output pulses would be combined and symmetrized by water-insulated radial-transmission-line impedance transformers [Phys. Rev. ST Accel. Beams 11, 030401 (2008)].

More Details

Precision electron flow measurements in a disk transmission line

Savage, Mark E.; Pointon, Timothy D.; Stoltzfus, Brian S.

An analytic model for electron flow in a system driving a fixed inductive load is described and evaluated with particle in cell simulations. The simple model allows determining the impedance profile for a magnetically insulated transmission line given the minimum gap desired, and the lumped inductance inside the transition to the minimum gap. The model allows specifying the relative electron flow along the power flow direction, including cases where the fractional electron flow decreases in the power flow direction. The electrons are able to return to the cathode because they gain energy from the temporally rising magnetic field. The simulations were done with small cell size to reduce numerical heating. An experiment to compare electron flow to the simulations was done. The measured electron flow is {approx}33% of the value from the simulations. The discrepancy is assumed to be due to a reversed electric field at the cathode because of the inductive load and falling electron drift velocity in the power flow direction. The simulations constrain the cathode electric field to zero, which gives the highest possible electron flow.

More Details

Initial design and results from an ion current collection diagnostic for the triggered plasma opening switch experiment

Digest of Technical Papers-IEEE International Pulsed Power Conference

Jackson, D.; Savage, Mark E.; Seidel, D.; Mendel, C.; Gilmore, M.

Study of the Triggered Plasma Opening Switch (TPOS) characteristics is in progress via an ion current collection diagnostic (ICCD), in addition to offline apparatus. This initial ion current collection diagnostic has been designed, fabricated, and tested on the TPOS in order to explore the opening profile of the main switch. The initial ion current collection device utilizes five collectors which are positioned perpendicularly to the main switch stage in order to collect radially traveling ions. It has been shown through analytical prowess that this specific geometry can be treated as a planar case of the Child-Langmuir law with only a 6% deviation from the cylindrical case. Additionally, magnetostatic simulations with self consistent space charge emitting surfaces of the main switch using the Trak code are under way. It is hoped that the simulations will provide evidence in support of both the analytical derivations and experimental data. Finally, an improved design of the ICCD (containing 12 collectors in the axial direction) is presently being implemented. © 2005 IEEE.

More Details