Publications

Results 26–50 of 52
Skip to search filters

Genomics-enabled sensor platform for rapid detection of viruses related to disease outbreak

Brozik, Susan M.; Polsky, Ronen P.; Campbell, DeAnna M.; Manginell, Ronald P.; Moorman, Matthew W.; Edwards, Thayne L.; Anderson, John M.; Pfeifer, Kent B.; Branch, Darren W.

More Details

Surface plasmon sensing of gas phase contaminants using optical fiber

Pfeifer, Kent B.; Thornberg, Steven M.; White, Michael I.

Fiber-optic gas phase surface plasmon resonance (SPR) detection of several contaminant gases of interest to state-of-health monitoring in high-consequence sealed systems has been demonstrated. These contaminant gases include H{sub 2}, H{sub 2}S, and moisture using a single-ended optical fiber mode. Data demonstrate that results can be obtained and sensitivity is adequate in a dosimetric mode that allows periodic monitoring of system atmospheres. Modeling studies were performed to direct the design of the sensor probe for optimized dimensions and to allow simultaneous monitoring of several constituents with a single sensor fiber. Testing of the system demonstrates the ability to detect 70mTorr partial pressures of H{sub 2} using this technique and <280 {micro}Torr partial pressures of H{sub 2}S. In addition, a multiple sensor fiber has been demonstrated that allows a single fiber to measure H{sub 2}, H{sub 2}S, and H{sub 2}O without changing the fiber or the analytical system.

More Details

Mass sensitive, Lorentz-Force actuated, MEMS preconcentrator and chemical sensor

ECS Transactions

Manginell, Ronald P.; Adkins, Douglas R.; Moorman, Matthew W.; Hadizadeh, Rameen; Copic, Davor; Porter, Daniel; Anderson, John M.; Wheeler, David R.; Pfeifer, Kent B.; Rumpf, Arthur

The mass-sensitive smart preconcentrator (SPC) consists of a Lorentz-Force-actuated MEMS resonator with an integral heater and surface coating for the collection of chemical analytes. Control circuitry is used to drive the SPC to resonance and measure its oscillation frequency. The frequency shift produced by adsorption of analyte on the SPC surface is inversely proportional to the mass of analyte collected. Thus, the SPC can measure when it has collected sufficient analyte for a downstream detection system. The limit of detection (LOD) of the SPC is less than 50 ppb for DMMP (dimethyl-methyl- phosphonate). At 1 ppm, less than 1 second collection of DMMP is sufficient to trigger analysis. An analytical model of operation of the SPC is used to predict the motion of the paddle and the shear modulus of silicon. © The Electrochemical Society.

More Details

Developing a laser-based ionization approach for detecting explosives with ion mobility spectrometry

Optics InfoBase Conference Papers

Headrick, Jeffrey M.; Reichardt, Thomas A.; Bambha, Ray B.; Kelley, Jude A.; Pfeifer, Kent B.; Bouchier, Francis A.

Rotationally resolved resonance-enhanced multiphoton ionization (REMPI) spectra of the NO photofragment from nitrobenzene have been observed for the A 2Σ+-X 2Π (1, 0) transition. These spectra were collected in an atmospheric-pressure nitrogen bath. © 2007 Optical Society of America.

More Details

Macro-meso-microsystems integration in LTCC : LDRD report

Rohde, Steven B.; Okandan, Murat O.; Pfeifer, Kent B.; De Smet, Dennis J.; Patel, Kamlesh P.; Ho, Clifford K.; Nordquist, Christopher N.; Walker, Charles A.; Rohrer, Brandon R.; Buerger, Stephen B.; Wroblewski, Brian W.

Low Temperature Cofired Ceramic (LTCC) has proven to be an enabling medium for microsystem technologies, because of its desirable electrical, physical, and chemical properties coupled with its capability for rapid prototyping and scalable manufacturing of components. LTCC is viewed as an extension of hybrid microcircuits, and in that function it enables development, testing, and deployment of silicon microsystems. However, its versatility has allowed it to succeed as a microsystem medium in its own right, with applications in non-microelectronic meso-scale devices and in a range of sensor devices. Applications include silicon microfluidic ''chip-and-wire'' systems and fluid grid array (FGA)/microfluidic multichip modules using embedded channels in LTCC, and cofired electro-mechanical systems with moving parts. Both the microfluidic and mechanical system applications are enabled by sacrificial volume materials (SVM), which serve to create and maintain cavities and separation gaps during the lamination and cofiring process. SVMs consisting of thermally fugitive or partially inert materials are easily incorporated. Recognizing the premium on devices that are cofired rather than assembled, we report on functional-as-released and functional-as-fired moving parts. Additional applications for cofired transparent windows, some as small as an optical fiber, are also described. The applications described help pave the way for widespread application of LTCC to biomedical, control, analysis, characterization, and radio frequency (RF) functions for macro-meso-microsystems.

More Details

Detection of carbon monoxide (CO) as a furnace byproduct using a rotating mask spectrometer

Pfeifer, Kent B.; Sinclair, Michael B.

Sandia National Laboratories, in partnership with the Consumer Product Safety Commission (CPSC), has developed an optical-based sensor for the detection of CO in appliances such as residential furnaces. The device is correlation radiometer based on detection of the difference signal between the transmission spectrum of the sample multiplied by two alternating synthetic spectra (called Eigen spectra). These Eigen spectra are derived from a priori knowledge of the interferents present in the exhaust stream. They may be determined empirically for simple spectra, or using a singular value decomposition algorithm for more complex spectra. Data is presented on the details of the design of the instrument and Eigen spectra along with results from detection of CO in background N{sub 2}, and CO in N{sub 2} with large quantities of interferent CO{sub 2}. Results indicate that using the Eigen spectra technique, CO can be measured at levels well below acceptable limits in the presence of strongly interfering species. In addition, a conceptual design is presented for reducing the complexity and cost of the instrument to a level compatible with consumer products.

More Details

Advanced polychromator systems for remote chemical sensing (LDRD project 52575)

Allen, James J.; Sinclair, Michael B.; Pfeifer, Kent B.

The objective of this LDRD project was to develop a programmable diffraction grating fabricated in SUMMiT V{trademark}. Two types of grating elements (vertical and rotational) were designed and demonstrated. The vertical grating element utilized compound leveraged bending and the rotational grating element used vertical comb drive actuation. This work resulted in two technical advances and one patent application. Also a new optical configuration of the Polychromator was demonstrated. The new optical configuration improved the optical efficiency of the system without degrading any other aspect of the system. The new configuration also relaxes some constraint on the programmable diffraction grating.

More Details

Nano electrode arrays for in-situ identification and quantification of chemicals in water

Yelton, William G.; Pfeifer, Kent B.

The nano electrode arrays for in-situ identification and quantification of chemicals in water progress in four major directions. (1) We developed and engineering three nanoelectrode array designs which operate in a portable field mode or as distributed sensor network for water systems. (2) To replace the fragile glass electrochemical cells using in the lab, we design and engineered field-ready sampling heads that combine the nanoelectrode arrays with a high-speed potentiostat. (3) To utilize these arrays in a portable system we design and engineered a light weight high-speed potentiostat with pulse widths from 2 psec. to 100 msec. or greater. (4) Finally, we developed the parameters for an analytical method in low-conductivity solutions for Pb(II) detection, with initial studies for the analysis of As(III) and As(V) analysis in natural water sources.

More Details

Embedded Self-Powered MicroSensors for Monitoring the Surety of Critical Buildings and Infrastructures

Pfeifer, Kent B.; Rumpf, Arthur N.; Leming, Sarah L.

Monitoring the condition of critical structures is vital for not only assuring occupant safety and security during naturally occurring and malevolent events, but also to determine the fatigue rate under normal aging conditions and to allow for efficient upgrades. This project evaluated the feasibility of applying integrated, remotely monitored micro-sensor systems to assess the structural performance of critical infrastructure. These measurement systems will provide forensic data on structural integrity, health, response, and overall structural performance in load environments such as aging, earthquake, severe wind, and blast attacks. We have investigated the development of ''self-powered'' sensor tags that can be used to monitor the state-of-health of a structure and can be embedded in that structure without compromising the integrity of the structure. A sensor system that is powered by converting structural stresses into electrical power via piezoelectric transducers has been demonstrated including work toward integration of that sensor with a novel radio frequency (RF) tagging technology as a means of remotely reading the data from the sensor.

More Details
Results 26–50 of 52