Dynamic Load Mechanical Modelling of a 10 MW Ganged Heliostat
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Multiphase computational models and tests of falling water droplets on inclined glass surfaces were developed to investigate the physics of impingement and potential of these droplets to self-clean glass surfaces for photovoltaic modules and heliostats. A multiphase volume-of-fluid model was developed in ANSYS Fluent to simulate the impinging droplets. The simulations considered different droplet sizes (1 mm and 3 mm), tilt angles (0°, 10°, and 45°), droplet velocities (1 m/s and 3 m/s), and wetting characteristics (wetting=47° contact angle and non-wetting = 93° contact angle). Results showed that the spread factor (maximum droplet diameter during impact divided by the initial droplet diameter) decreased with increasing inclination angle due to the reduced normal force on the surface. The hydrophilic surface yielded greater spread factors than the hydrophobic surface in all cases. With regard to impact forces, the greater surface tilt angles yielded lower normal forces, but higher shear forces. Experiments showed that the experimentally observed spread factor (maximum droplet diameter during impact divided by the initial droplet diameter) was significantly larger than the simulated spread factor. Observed spread factors were on the order of 5 - 6 for droplet velocities of ~3 m/s, whereas the simulated spread factors were on the order of 2. Droplets were observed to be mobile following impact only for the cases with 45° tilt angle, which matched the simulations. An interesting phenomenon that was observed was that shortly after being released from the nozzle, the water droplet oscillated (like a trampoline) due to the "snapback" caused by the surface tension of the water droplet being released from the nozzle. This oscillation impacted the velocity immediately after the release. Future work should evaluate the impact of parameters such as tilt angle and surface wettability on the impact of particle/soiling uptake and removal to investigate ways that photovoltaic modules and heliostats can be designed to maximize self-cleaning.
Abstract not provided.
While arc-faults are rare in electrical installations, many documented events have led to fires that resulted in significant damage to energy-generation, commercial and residential systems, as well as surrounding structures, in both the United States and abroad. Arc-plasma discharges arise over time due to a variety of reliability issues related to cable material degradation, electrical and mechanical stresses or acute conductive wiring dislocations. These may lead to discontinuity between energized conductors, facilitating arcing events and fires. Arc-flash events rapidly release significant energy in a localized volume, where the electric arc experiences a reduction in resistance. This facilitates a reduction in electrical resistance as the arc temperature and pressure can increase rapidly. Strong pressure waves, electromagnetic interference (EMI), and intense light from an arc pose a threat to electrical worker safety and system equipment. This arc-fault primer provides basic fundamental insight into arc-fault plasma discharges, and an overview of direct current (DC) and alternating current (AC) arc-fault phenomena. This primer also covers pressure waves and EMI arc-fault hazard analyses related to incident energy prediction and potential damage analysis. Mitigation strategies are also discussed related to engineering design and employment of protective devices including arc-fault circuit interrupters (AFCIs). Best practices related to worker safety are also covered, especially as they pertain to electrical codes and standards, particularly Institute of Electrical and Electronics Engineers (IEEE) 1584 and National Fire Protection Agency (NFPA) 70E. Throughout the primer various modelling and test capabilities at Sandia National Laboratories are also covered, especially as they relate to novel methods of arc-fault/arc-flash characterization and mitigation approaches. Herein, this work describes methods for producing and characterizing controlled, sustained arcs at atmospheric pressures as well as methods for mitigation with novel materials.
Concentrating solar power (CSP) utilizes solar thermal energy to drive a thermal power cycle for the generation of electricity. CSP systems are facilitated as large, centralized power plants , such as power towers and trough systems, to take advantage of ec onomies of scale through dispatchable thermal energy storage, which is a principle advantage over other energy generation systems . Additionally, the combination of large solar concentration ratios with high solar conversion efficiencies provides a strong o pportunity of employment of specific power cycles such as the Brayton gas cycle that utilizes super critical fluids such as supercritical carbon dioxide (s CO 2 ) , compared to other sola r - fossil hybrid power plants. A comprehensive thermal - fluids examination is provided by this work of various heat transfer phenomena evident in CSP technologies. These include sub - systems and heat transfer fundamental phenomena evident within CSP systems , which include s receivers, heat transfer fluids (HTFs), thermal storage me dia and system designs , thermodynamic power block systems/components, as well as high - temperature materials. This work provides literature reviews, trade studies, and phenomenological comparisons of heat transfer media (HTM) and components and systems, all for promotion of high performance and efficient CSP systems. In addition, f urther investigations are also conducted that provide advanced heat transfer modeling approaches for gas - particle receiver systems , as well as performance/efficiency enhancement re commendations, particularly for solarized supercritical power systems .
Abstract not provided.
Sodium as a heat transfer fluid (HTF) can achieve temperatures above 700°C to improve power cycle performance for reducing large infrastructure costs of high-temperature systems. Current concentrating solar power (CSP) sensible HTF’s (e.g. air, salts) have poor thermal conductivity, and thus low heat transfer capabilities, requiring a large receiver. The high thermal conductivity of sodium has demonstrated high heat transfer rates on dish and towers systems, which allow a reduction in receiver area by a factor of two to four, reducing re-radiation and convection losses and cost by a similar factor. Sodium produces saturated vapor at pressures suitable for transport starting at 600°C and reaches one atmosphere at 870°C, providing a wide range of suitable latent operating conditions that match proposed high temperature, isothermal input power cycles. This advantage could increase the receiver and system efficiency while lowering the cost of CSP tower systems. Although there are a number of desirable thermal performance advantages associated with sodium, its propensity to rapidly oxidize presents safety challenges. This investigation presents a literature review that captures historical operations/handling lessons for advanced sodium systems, and the current state-of-knowledge related to sodium combustion behavior. Technical and operational solutions addressing sodium safety and applications in CSP will be discussed, including unique safety hazards and advantages using latent sodium. Operation and maintenance experience from the nuclear industry with sensible and latent systems will also be discussed in the context of safety challenges and risk mitigation solutions.
Abstract not provided.
Abstract not provided.
2015 IEEE 42nd Photovoltaic Specialist Conference, PVSC 2015
Three balance of systems (BOS) connector designs common to industry were investigated as a means of assessing reliability from the perspective of arc fault risk. These connectors were aged in field and laboratory environments and performance data captured for future development of a reliability model. Comparison of connector resistance measured during damp heat, mixed flowing gas and field exposure in a light industrial environment indicated disparities in performance across the three designs. Performance was, in part, linked to materials of construction. A procedure was developed to evaluate new and aged connectors for arc fault risk and tested for one of the designs. Those connectors exposed to mixed flowing gas corrosion exhibited considerable Joule heating that may enhance arcing behavior, suggesting temperature monitoring as a potential method for arc fault prognostics. These findings, together with further characterization of connector aging, can provide operators of photovoltaic installations the information necessary to develop a data-driven approach to BOS connector maintenance as well as opportunities for arc fault prognostics.
The continued exponential growth of photovoltaic technologies paves a path to a solar-powered world, but requires continued progress toward low-cost, high-reliability, high-performance photovoltaic (PV) systems. High reliability is an essential element in achieving low-cost solar electricity by reducing operation and maintenance (O&M) costs and extending system lifetime and availability, but these attributes are difficult to verify at the time of installation. Utilities, financiers, homeowners, and planners are demanding this information in order to evaluate their financial risk as a prerequisite to large investments. Reliability research and development (R&D) is needed to build market confidence by improving product reliability and by improving predictions of system availability, O&M cost, and lifetime. This project is focused on understanding, predicting, and improving the reliability of PV systems. The two areas being pursued include PV arc-fault and ground fault issues, and inverter reliability.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Solar spectral data for all parts of the US is limited due in part to the high cost of commercial spectrometers. Solar spectral information is necessary for accurate photovoltaic (PV) performance forecasting, especially for large utility-scale PV installations. A low-cost solar spectral sensor would address the obstacles and needs. In this report, a novel low-cost, discrete- band sensor device, comprised of five narrow-band sensors, is described. The hardware is comprised of commercial-off-the-shelf components to keep the cost low. Data processing algorithms were developed and are being refined for robustness. PV module short-circuit current ( I sc ) prediction methods were developed based on interaction-terms regression methodology and spectrum reconstruction methodology for computing I sc . The results suggest the computed spectrum using the reconstruction method agreed well with the measured spectrum from the wide-band spectrometer (RMS error of 38.2 W/m 2 -nm). Further analysis of computed I sc found a close correspondence of 0.05 A RMS error. The goal is for ubiquitous adoption of the low-cost spectral sensor in solar PV and other applications such as weather forecasting.
2014 IEEE 40th Photovoltaic Specialist Conference, PVSC 2014
While arc-faults are rare in photovoltaic installations, more than a dozen documented arc-faults have led to fires and resulted in significant damage to the PV system and surrounding structures. In the United States, National Electrical Code® (NEC) 690.11 requires a listed arc fault protection device on new PV systems. In order to list new arc-fault circuit interrupters (AFCIs), Underwriters Laboratories created the certification outline of investigation UL 1699B. The outline only requires AFCI devices to be tested at arc powers between 300-900 W; however, arcs of much less power are capable of creating fires in PV systems. In this work we investigate the characteristics of low power (100-300 W) arc-faults to determine the potential for fires, appropriate AFCI trip times, and the characteristics of the pyrolyzation process. This analysis was performed with experimental tests of arc-faults in close proximity to three polymer materials common in PV systems, e.g., polycarbonate, PET, and nylon 6,6. Two polymer geometries were tested to vary the presence of oxygen in the DC arc plasma. The samples were also exposed to arcs generated with different material geometries, arc power levels, and discharge times to identify ignition times. To better understand the burn characteristics of different polymers in PV systems, thermal decomposition of the sheath materials was performed using infrared spectra analysis. Overall a trip time of less than 2 seconds is recommended for the suppression of fire ignition during arc-fault events.
2014 IEEE 40th Photovoltaic Specialist Conference, PVSC 2014
Many photovoltaic (PV) direct current (DC) arc-fault detectors use the frequency content of the PV system to detect arcs. The spectral content is influenced by the duration and power of the arc, surrounding insulation material geometry and chemistry, and electrode geometry. A parametric analysis was conducted in order to inform the Underwriters Laboratories (UL) 1699B ('Photovoltaic DC Arc-Fault Circuit Protection') Standards Technical Panel (STP) of improvements to arc-fault generation methods in the certification standard. These recommendations are designed to reduce the complexity of the experimental setup, improve testing repeatability, and quantify the uncertainty of the arc-fault radio frequency (RF) noise generated by different PV arcs in the field. In this investigation, we (a) discuss the differences in establishing and sustaining arc-faults for a number of different test configurations and (b) compare the variability in arc-fault spectral content for each respective test, and analyze the evolution of the RF signature over the duration of the fault; with the ultimate goal of determining the most repeatable, 'worst case' tests for adoption by UL.
2014 IEEE 40th Photovoltaic Specialist Conference, PVSC 2014
This work investigates balance of systems (BOS) connector reliability from the perspective of arc fault risk. Accelerated tests were performed on connectors for future development of a reliability model. Thousands of hours of damp heat and atmospheric corrosion tests found BOS connectors to be resilient to corrosion-related degradation. A procedure was also developed to evaluate new and aged connectors for arc fault risk. The measurements show that arc fault risk is dependent on a combination of materials composition as well as design geometry. Thermal measurements as well as optical emission spectroscopy were also performed to further characterize the arc plasma. Together, the degradation model, arc fault risk assessment technique, and characterization methods can provide operators of photovoltaic installations information necessary to develop a data-driven plan for BOS connector maintenance as well as identify opportunities for arc fault prognostics.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
AIP Conference Proceedings
The solar spectrum varies with atmospheric conditions and composition, and can have significant impacts on the output power performance of each junction in a concentrating solar photovoltaic (CPV) system, with direct implications on the junction that is current-limiting. The effect of changing solar spectrum on CPV module power production has previously been characterized by various spectral performance parameters such as air mass (AM) for both single and multi-junction module technologies. However, examinations of outdoor test results have shown substantial uncertainty contributions by many of these parameters, including air mass, for the determination of projected power and energy production. Using spectral data obtained from outdoor spectrometers, with a spectral range of 336nm-1715nm, this investigation examines precipitable water (PW), aerosol and dust variability effects on incident spectral irradiance. This work then assesses air mass and other spectral performance parameters, including a new atmospheric component spectral factor (ACSF), to investigate iso-cell, stacked multijunction and single-junction c-Si module performance data directly with measured spectrum. This will then be used with MODTRAN5® to determine if spectral composition can account for daily and seasonal variability of the short-circuit current density Jsc and the maximum output power Pmp values. For precipitable water, current results show good correspondence between the modeled atmospheric component spectral factor and measured data with an average rms error of 0.013, for all three iso-cells tested during clear days over a one week time period. Results also suggest average variations in ACSF factors with respect to increasing precipitable water of 8.2%/cmH2O, 1.3%/cmH2O, 0.2%/cmH2O and 1.8%/cmH2O for GaInP, GaAs, Ge and c-Si cells, respectively at solar noon and an AM value of 1.0. For ozone, the GaInP cell had the greatest sensitivity to increasing ozone levels with an ACSF variation of 0.07%/cmO3. For the desert dust wind study, consistent ACSF behavior between all iso-cells and c-Si was found, with only significant reductions beyond 40mph.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.