Spherical Crystal Backlighting at Z
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Journal of Physics: Conference Series
Several magnetized liner inertial fusion (MagLIF) experiments have been conducted on the Z accelerator at Sandia National Laboratories since late 2013. Measurements of the primary DD (2.45 MeV) neutrons for these experiments suggest that the neutron production is thermonuclear. Primary DD yields up to 3e12 with ion temperatures ∼2-3 keV have been achieved. Measurements of the secondary DT (14 MeV) neutrons indicate that the fuel is significantly magnetized. Measurements of down-scattered neutrons from the beryllium liner suggest ρRliner∼1g/cm2. Neutron bang times, estimated from neutron time-of-flight (nTOF) measurements, coincide with peak x-ray production. Plans to improve and expand the Z neutron diagnostic suite include neutron burn-history diagnostics, increased sensitivity and higher precision nTOF detectors, and neutron recoil-based yield and spectral measurements.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Proceedings of SPIE - The International Society for Optical Engineering
The Hippogriff camera developed at Sandia National Laboratories as part of the Ultra-Fast X-ray Imager (UXI) program is a high-speed, multi-frame, time-gated imager for use on a wide variety of High Energy Density (HED) physics experiments on both Sandia's Z-Machine and the National Ignition Facility. The camera is a 1024 x 448 pixel array with 25 μm spatial resolution, containing 2 frames per pixel natively and has achieved 2 ns minimum integration time. It is sensitive to both optical photons as well as soft X-rays up to ∼6 keV. The Hippogriff camera is the second generation UXI camera that contains circuitry to trade spatial resolution for additional frames of temporal coverage. The user can reduce the row-wise spatial resolution from the native 25 μm to increase the number of frames in a data set to 4 frames at 50 μm or 8 frames at 100 μm spatial resolution. This feature, along with both optical and X-ray sensitivity, facilitates additional experimental flexibility. Minimum signal is 1500 erms and full well is 1.5 million e-.
High Power Laser Science and Engineering
We have developed high damage threshold filters to modify the spatial profile of a high energy laser beam. The filters are formed by laser ablation of a transmissive window. The ablation sites constitute scattering centers which can be filtered in a subsequent spatial filter. By creating the filters in dielectric materials, we see an increased laser-induced damage threshold from previous filters created using 'metal on glass' lithography.
High Power Laser Science and Engineering
The Z-backlighter laser facility primarily consists of two high energy, high-power laser systems. Z-Beamlet laser (ZBL) (Rambo et al., Appl. Opt. 44, 2421 (2005)) is a multi-kJ-class, nanosecond laser operating at 1054 nm which is frequency doubled to 527 nm in order to provide x-ray backlighting of high energy density events on the Z-machine. Z-Petawatt (ZPW) (Schwarz et al., J. Phys.: Conf. Ser. 112, 032020 (2008)) is a petawatt-class system operating at 1054 nm delivering up to 500 J in 500 fs for backlighting and various short-pulse laser experiments (see also Figure 10 for a facility overview). With the development of the magnetized liner inertial fusion (MagLIF) concept on the Z-machine, the primary backlighting missions of ZBL and ZPW have been adjusted accordingly. As a result, we have focused our recent efforts on increasing the output energy of ZBL from 2 to 4 kJ at 527 nm by modifying the fiber front end to now include extra bandwidth (for stimulated Brillouin scattering suppression). The MagLIF concept requires a well-defined/behaved beam for interaction with the pressurized fuel. Hence we have made great efforts to implement an adaptive optics system on ZBL and have explored the use of phase plates. We are also exploring concepts to use ZPW as a backlighter for ZBL driven MagLIF experiments. Alternatively, ZPW could be used as an additional fusion fuel pre-heater or as a temporally flexible high energy pre-pulse. All of these concepts require the ability to operate the ZPW in a nanosecond long-pulse mode, in which the beam can co-propagate with ZBL. Some of the proposed modifications are complete and most of them are well on their way.
Proceedings of SPIE - The International Society for Optical Engineering
Sandia National Laboratories is pursuing a variation of Magneto-Inertial Fusion called Magnetized Liner Inertial Fusion, or MagLIF. The MagLIF approach requires magnetization of the deuterium fuel, which is accomplished by an initial external B-Field and laser-driven pre-heat. While magnetization is crucial to the concept, it is challenging to couple sufficient energy to the fuel, since laser-plasma instabilities exist, and a compromise between laser spot size, laser entrance window thickness, and fuel density must be found. Nonlinear processes in laser plasma interaction, or laser-plasma instabilities (LPI), complicate the deposition of laser energy by enhanced absorption, backscatter, filamentation and beam-spray. Key LPI processes are determined, and mitigation methods are discussed. Results with and without improvement measures are presented.
Proceedings of SPIE - The International Society for Optical Engineering
The Z-Backlighter Laser Facility at Sandia National Laboratories was developed to enable high energy density physics experiments in conjunction with the Z Pulsed Power Facility at Sandia National Laboratories, with an emphasis on backlighting. Since the first laser system there became operational in 2001, the facility has continually evolved to add new capability and new missions. The facility currently has several high energy laser systems including the nanosecond/multi-kilojoule Z-Beamlet Laser (ZBL), the sub-picosecond/kilojoule-class Z-Petawatt (ZPW) Laser, and the smaller nanosecond/100 J-class Chaco laser. In addition to these, the backlighting mission requires a regular stream of coated consumable optics such as debris shields and vacuum windows, which led to the development of the Sandia Optics Support Facility to support the unique high damage threshold optical coating needs described.
Abstract not provided.
Review of Scientific Instruments
Imaging systems that include a specific source, imaging concept, geometry, and detector have unique properties such as signal-to-noise ratio, dynamic range, spatial resolution, distortions, and contrast. Some of these properties are inherently connected, particularly dynamic range and spatial resolution. It must be emphasized that spatial resolution is not a single number but must be seen in the context of dynamic range and consequently is better described by a function or distribution. We introduce the "dynamic granularity" G dyn as a standardized, objective relation between a detector's spatial resolution (granularity) and dynamic range for complex imaging systems in a given environment rather than the widely found characterization of detectors such as cameras or films by themselves. This relation can partly be explained through consideration of the signal's photon statistics, background noise, and detector sensitivity, but a comprehensive description including some unpredictable data such as dust, damages, or an unknown spectral distribution will ultimately have to be based on measurements. Measured dynamic granularities can be objectively used to assess the limits of an imaging system's performance including all contributing noise sources and to qualify the influence of alternative components within an imaging system. This article explains the construction criteria to formulate a dynamic granularity and compares measured dynamic granularities for different detectors used in the X-ray backlighting scheme employed at Sandia's Z-Backlighter facility.
Abstract not provided.
Digest of Technical Papers-IEEE International Pulsed Power Conference
An experiment platform has been designed to study vacuum power flow in magnetically insulated transmission lines (MITLs) the platform is driven by the Mykonos-V LTD accelerator to drive a coaxial MITL with a millimeter-scale anode-cathode gap the experiments conducted quantify the current loss in the MITL with respect to vacuum pumpdown time and vacuum pressure. MITL gaps between 1.0 mm and 1.3 mm were tested the experiment results revealed large differences in performance for the 1.0 and 1.3 mm gaps the 1.0 mm gap resulted in current losses of 40%-60% of the peak current the 1.3 mm gap resulted in current losses of less than 5% of peak current. Classical MITL models that neglect plasma expansion predict that there should be zero current loss, after magnetic insulation is established, for both of these gaps.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.