Publications

Results 51–75 of 132
Skip to search filters

Sensitivity Analysis in Xyce

Keiter, Eric R.; Swiler, Laura P.; Russo, Thomas V.; Wilcox, Ian Z.

Parametric sensitivities of dynamic system responses are very useful in a variety of applications, including circuit optimization and uncertainty quantification. Sensitivity calculation methods fall into two related categories: direct and adjoint methods. Effective implementation of such methods in a production circuit simulator poses a number of technical challenges, including instrumentation of device models. This report documents several years of work developing and implementing di- rect and adjoint sensitivity methods in the Xyce circuit simulator. Much of this work sponsored by the Laboratory Directed Research and Development (LDRD) Program at Sandia National Labora- tories, under project LDRD 14-0788.

More Details

Advanced Uncertainty Quantification Methods for Circuit Simulation: Final Report LDRD 2016-0845

Keiter, Eric R.; Swiler, Laura P.; Wilcox, Ian Z.

This report summarizes the methods and algorithms that were developed on the Sandia National Laboratory LDRD project entitled "Advanced Uncertainty Quantification Methods for Circuit Sim- ulation", which was project # 173331 and proposal # 2016-0845. As much of our work has been published in other reports and publications, this report gives an brief summary. Those who are in- terested in the technical details are encouraged to read the full published results and also contact the report authors for the status of follow-on projects.

More Details

Xyce™ Parallel Electronic Simulator Users' Guide, Version 6.5

Keiter, Eric R.; Aadithya, Karthik V.; Mei, Ting M.; Russo, Thomas V.; Schiek, Richard S.; Sholander, Peter E.; Thornquist, Heidi K.; Verley, Jason V.

This manual describes the use of the Xyce Parallel Electronic Simulator. Xyce has been designed as a SPICE-compatible, high-performance analog circuit simulator, and has been written to support the simulation needs of the Sandia National Laboratories electrical designers. This development has focused on improving capability over the current state-of-the-art in the following areas: Capability to solve extremely large circuit problems by supporting large-scale parallel computing platforms (up to thousands of processors). This includes support for most popular parallel and serial computers. A differential-algebraic-equation (DAE) formulation, which better isolates the device model package from solver algorithms. This allows one to develop new types of analysis without requiring the implementation of analysis-specific device models. Device models that are specifically tailored to meet Sandia's needs, including some radiation- aware devices (for Sandia users only). Object-oriented code design and implementation using modern coding practices. Xyce is a parallel code in the most general sense of the phrase -- a message passing parallel implementation -- which allows it to run efficiently a wide range of computing platforms. These include serial, shared-memory and distributed-memory parallel platforms. Attention has been paid to the specific nature of circuit-simulation problems to ensure that optimal parallel efficiency is achieved as the number of processors grows. The information herein is subject to change without notice. Copyright © 2002-2016 Sandia Corporation. All rights reserved.

More Details

Xyce™ Parallel Electronic Simulator Reference Guide, Version 6.5

Keiter, Eric R.; Aadithya, Karthik V.; Mei, Ting M.; Russo, Thomas V.; Schiek, Richard S.; Sholander, Peter E.; Thornquist, Heidi K.; Verley, Jason V.

This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users’ Guide. The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users’ Guide. The information herein is subject to change without notice. Copyright © 2002-2016 Sandia Corporation. All rights reserved.

More Details

Xyce Parallel Electronic Simulator Users Guide Version 6.4

Keiter, Eric R.; Mei, Ting M.; Russo, Thomas V.; Schiek, Richard S.; Sholander, Peter E.; Thornquist, Heidi K.; Verley, Jason V.; Baur, David G.

This manual describes the use of the Xyce Parallel Electronic Simulator. Xyce has been de- signed as a SPICE-compatible, high-performance analog circuit simulator, and has been written to support the simulation needs of the Sandia National Laboratories electrical designers. This development has focused on improving capability over the current state-of-the-art in the following areas: Capability to solve extremely large circuit problems by supporting large-scale parallel com- puting platforms (up to thousands of processors). This includes support for most popular parallel and serial computers. A differential-algebraic-equation (DAE) formulation, which better isolates the device model package from solver algorithms. This allows one to develop new types of analysis without requiring the implementation of analysis-specific device models. Device models that are specifically tailored to meet Sandia's needs, including some radiation- aware devices (for Sandia users only). Object-oriented code design and implementation using modern coding practices. Xyce is a parallel code in the most general sense of the phrase -- a message passing parallel implementation -- which allows it to run efficiently a wide range of computing platforms. These include serial, shared-memory and distributed-memory parallel platforms. Attention has been paid to the specific nature of circuit-simulation problems to ensure that optimal parallel efficiency is achieved as the number of processors grows. Trademarks The information herein is subject to change without notice. Copyright c 2002-2015 Sandia Corporation. All rights reserved. Xyce TM Electronic Simulator and Xyce TM are trademarks of Sandia Corporation. Portions of the Xyce TM code are: Copyright c 2002, The Regents of the University of California. Produced at the Lawrence Livermore National Laboratory. Written by Alan Hindmarsh, Allan Taylor, Radu Serban. UCRL-CODE-2002-59 All rights reserved. Orcad, Orcad Capture, PSpice and Probe are registered trademarks of Cadence Design Systems, Inc. Microsoft, Windows and Windows 7 are registered trademarks of Microsoft Corporation. Medici, DaVinci and Taurus are registered trademarks of Synopsys Corporation. Amtec and TecPlot are trademarks of Amtec Engineering, Inc. Xyce 's expression library is based on that inside Spice 3F5 developed by the EECS Department at the University of California. The EKV3 MOSFET model was developed by the EKV Team of the Electronics Laboratory-TUC of the Technical University of Crete. All other trademarks are property of their respective owners. Contacts Bug Reports (Sandia only) http://joseki.sandia.gov/bugzilla http://charleston.sandia.gov/bugzilla World Wide Web http://xyce.sandia.gov http://charleston.sandia.gov/xyce (Sandia only) Email xyce@sandia.gov (outside Sandia) xyce-sandia@sandia.gov (Sandia only)

More Details

Xyce Parallel Electronic Simulator Reference Guide Version 6.4

Keiter, Eric R.; Mei, Ting M.; Russo, Thomas V.; Schiek, Richard S.; Sholander, Peter E.; Thornquist, Heidi K.; Verley, Jason V.; Baur, David G.

This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users' Guide [1] . The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce . This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users' Guide [1] . Trademarks The information herein is subject to change without notice. Copyright c 2002-2015 Sandia Corporation. All rights reserved. Xyce TM Electronic Simulator and Xyce TM are trademarks of Sandia Corporation. Portions of the Xyce TM code are: Copyright c 2002, The Regents of the University of California. Produced at the Lawrence Livermore National Laboratory. Written by Alan Hindmarsh, Allan Taylor, Radu Serban. UCRL-CODE-2002-59 All rights reserved. Orcad, Orcad Capture, PSpice and Probe are registered trademarks of Cadence Design Systems, Inc. Microsoft, Windows and Windows 7 are registered trademarks of Microsoft Corporation. Medici, DaVinci and Taurus are registered trademarks of Synopsys Corporation. Amtec and TecPlot are trademarks of Amtec Engineering, Inc. Xyce 's expression library is based on that inside Spice 3F5 developed by the EECS Department at the University of California. The EKV3 MOSFET model was developed by the EKV Team of the Electronics Laboratory-TUC of the Technical University of Crete. All other trademarks are property of their respective owners. Contacts Bug Reports (Sandia only) http://joseki.sandia.gov/bugzilla http://charleston.sandia.gov/bugzilla World Wide Web http://xyce.sandia.gov http://charleston.sandia.gov/xyce (Sandia only) Email xyce@sandia.gov (outside Sandia) xyce-sandia@sandia.gov (Sandia only)

More Details

Precision circuit calculations in hostile environments

Sandia journal manuscript; Not yet accepted for publication

Hembree, Charles E.; Keiter, Eric R.

Sensing and calculating electronic systems with stringent accuracy requirements use internal standard voltages for references. Conceptually, this is related to using some unit measurement for counting any quantity. The high precision electronic components used in systems in the nation’s stockpile also make use of these standard voltages. The need for stable voltage references has been long-standing in the overall electronics industry. For many applications, the most pressing need is for stability of a reference voltage as the circuit temperature varies. Typical circuit components have temperature coefficients for their operational characteristics that are given in some delta per degree centigrade and these coefficients can be either positive or negative. Thus, it is natural to consider building a circuit out of components that have complementary temperature coefficients so that the operating characteristics of the circuit have a net zero temperature coefficient. This is the fundamental basis of precision voltage reference (PVR) circuit operation and it is straightforward to extend this type of stabilization to reduce shifts caused by hostile environment radiation.

More Details

Xyce Parallel Electronic Simulator Users Guide Version 6.2

Keiter, Eric R.; Mei, Ting M.; Russo, Thomas V.; Schiek, Richard S.; Sholander, Peter E.; Thornquist, Heidi K.; Verley, Jason V.; Baur, David G.

This manual describes the use of the Xyce Parallel Electronic Simulator. Xyce has been de- signed as a SPICE-compatible, high-performance analog circuit simulator, and has been written to support the simulation needs of the Sandia National Laboratories electrical designers. This development has focused on improving capability over the current state-of-the-art in the following areas: Capability to solve extremely large circuit problems by supporting large-scale parallel com- puting platforms (up to thousands of processors). This includes support for most popular parallel and serial computers. A differential-algebraic-equation (DAE) formulation, which better isolates the device model package from solver algorithms. This allows one to develop new types of analysis without requiring the implementation of analysis-specific device models. Device models that are specifically tailored to meet Sandia's needs, including some radiation- aware devices (for Sandia users only). Object-oriented code design and implementation using modern coding practices. Xyce is a parallel code in the most general sense of the phrase -- a message passing parallel implementation -- which allows it to run efficiently a wide range of computing platforms. These include serial, shared-memory and distributed-memory parallel platforms. Attention has been paid to the specific nature of circuit-simulation problems to ensure that optimal parallel efficiency is achieved as the number of processors grows. Trademarks The information herein is subject to change without notice. Copyright c 2002-2014 Sandia Corporation. All rights reserved. Xyce TM Electronic Simulator and Xyce TM are trademarks of Sandia Corporation. Portions of the Xyce TM code are: Copyright c 2002, The Regents of the University of California. Produced at the Lawrence Livermore National Laboratory. Written by Alan Hindmarsh, Allan Taylor, Radu Serban. UCRL-CODE-2002-59 All rights reserved. Orcad, Orcad Capture, PSpice and Probe are registered trademarks of Cadence Design Systems, Inc. Microsoft, Windows and Windows 7 are registered trademarks of Microsoft Corporation. Medici, DaVinci and Taurus are registered trademarks of Synopsys Corporation. Amtec and TecPlot are trademarks of Amtec Engineering, Inc. Xyce 's expression library is based on that inside Spice 3F5 developed by the EECS Department at the University of California. The EKV3 MOSFET model was developed by the EKV Team of the Electronics Laboratory-TUC of the Technical University of Crete. All other trademarks are property of their respective owners. Contacts Bug Reports (Sandia only) http://joseki.sandia.gov/bugzilla http://charleston.sandia.gov/bugzilla World Wide Web http://xyce.sandia.gov http://charleston.sandia.gov/xyce (Sandia only) Email xyce@sandia.gov (outside Sandia) xyce-sandia@sandia.gov (Sandia only)

More Details

Xyce parallel electronic simulator users guide, version 6.1

Keiter, Eric R.; Mei, Ting M.; Russo, Thomas V.; Schiek, Richard S.; Sholander, Peter E.; Thornquist, Heidi K.; Verley, Jason V.

This manual describes the use of the Xyce Parallel Electronic Simulator. Xyce has been designed as a SPICE-compatible, high-performance analog circuit simulator, and has been written to support the simulation needs of the Sandia National Laboratories electrical designers. This development has focused on improving capability over the current state-of-the-art in the following areas; Capability to solve extremely large circuit problems by supporting large-scale parallel computing platforms (up to thousands of processors). This includes support for most popular parallel and serial computers; A differential-algebraic-equation (DAE) formulation, which better isolates the device model package from solver algorithms. This allows one to develop new types of analysis without requiring the implementation of analysis-specific device models; Device models that are specifically tailored to meet Sandia's needs, including some radiationaware devices (for Sandia users only); and Object-oriented code design and implementation using modern coding practices. Xyce is a parallel code in the most general sense of the phrase-a message passing parallel implementation-which allows it to run efficiently a wide range of computing platforms. These include serial, shared-memory and distributed-memory parallel platforms. Attention has been paid to the specific nature of circuit-simulation problems to ensure that optimal parallel efficiency is achieved as the number of processors grows.

More Details

Xyce parallel electronic simulator reference guide, version 6.1

Keiter, Eric R.; Mei, Ting M.; Russo, Thomas V.; Schiek, Richard S.; Sholander, Peter E.; Thornquist, Heidi K.; Verley, Jason V.

This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users<U+2019> Guide [1] . The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users<U+2019> Guide [1] .

More Details

Xyce parallel electronic simulator users' guide, Version 6.0.1

Keiter, Eric R.; Warrender, Christina E.; Mei, Ting M.; Russo, Thomas V.; Schiek, Richard S.; Thornquist, Heidi K.; Verley, Jason V.; Coffey, Todd S.; Pawlowski, Roger P.

This manual describes the use of the Xyce Parallel Electronic Simulator. Xyce has been designed as a SPICE-compatible, high-performance analog circuit simulator, and has been written to support the simulation needs of the Sandia National Laboratories electrical designers. This development has focused on improving capability over the current state-of-the-art in the following areas: Capability to solve extremely large circuit problems by supporting large-scale parallel computing platforms (up to thousands of processors). This includes support for most popular parallel and serial computers. A differential-algebraic-equation (DAE) formulation, which better isolates the device model package from solver algorithms. This allows one to develop new types of analysis without requiring the implementation of analysis-specific device models. Device models that are specifically tailored to meet Sandias needs, including some radiationaware devices (for Sandia users only). Object-oriented code design and implementation using modern coding practices. Xyce is a parallel code in the most general sense of the phrase a message passing parallel implementation which allows it to run efficiently a wide range of computing platforms. These include serial, shared-memory and distributed-memory parallel platforms. Attention has been paid to the specific nature of circuit-simulation problems to ensure that optimal parallel efficiency is achieved as the number of processors grows.

More Details

Xyce parallel electronic simulator reference guide, Version 6.0.1

Keiter, Eric R.; Mei, Ting M.; Russo, Thomas V.; Pawlowski, Roger P.; Schiek, Richard S.; Coffey, Todd S.; Thornquist, Heidi K.; Verley, Jason V.; Warrender, Christina E.

This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users Guide [1] . The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users Guide [1] .

More Details

Building guide : how to build Xyce from source code

Keiter, Eric R.; Russo, Thomas V.; Schiek, Richard S.; Thornquist, Heidi K.; Mei, Ting M.; Verley, Jason V.; Sholander, Peter E.

While Xyce uses the Autoconf and Automake system to configure builds, it is often necessary to perform more than the customary %E2%80%9C./configure%E2%80%9D builds many open source users have come to expect. This document describes the steps needed to get Xyce built on a number of common platforms.

More Details

Xyce parallel electronic simulator users guide, version 6.0

Russo, Thomas V.; Mei, Ting M.; Keiter, Eric R.; Schiek, Richard S.; Thornquist, Heidi K.; Verley, Jason V.; Coffey, Todd S.; Pawlowski, Roger P.; Warrender, Christina E.

This manual describes the use of the Xyce Parallel Electronic Simulator. Xyce has been designed as a SPICE-compatible, high-performance analog circuit simulator, and has been written to support the simulation needs of the Sandia National Laboratories electrical designers. This development has focused on improving capability over the current state-of-the-art in the following areas: Capability to solve extremely large circuit problems by supporting large-scale parallel computing platforms (up to thousands of processors). This includes support for most popular parallel and serial computers. A differential-algebraic-equation (DAE) formulation, which better isolates the device model package from solver algorithms. This allows one to develop new types of analysis without requiring the implementation of analysis-specific device models. Device models that are specifically tailored to meet Sandias needs, including some radiationaware devices (for Sandia users only). Object-oriented code design and implementation using modern coding practices. Xyce is a parallel code in the most general sense of the phrase a message passing parallel implementation which allows it to run efficiently a wide range of computing platforms. These include serial, shared-memory and distributed-memory parallel platforms. Attention has been paid to the specific nature of circuit-simulation problems to ensure that optimal parallel efficiency is achieved as the number of processors grows.

More Details

Xyce parallel electronic simulator reference guide, version 6.0

Keiter, Eric R.; Mei, Ting M.; Russo, Thomas V.; Pawlowski, Roger P.; Schiek, Richard S.; Coffey, Todd S.; Thornquist, Heidi K.; Verley, Jason V.; Warrender, Christina E.

This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users Guide [1] . The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users Guide [1] .

More Details
Results 51–75 of 132