Publications

Results 76–100 of 273
Skip to search filters

Stagnation Morphology in Magnetized Liner Inertial Fusion Experiments

Gomez, Matthew R.; Harding, Eric H.; Ampleford, David A.; Jennings, Christopher A.; Awe, Thomas J.; Chandler, Gordon A.; Glinsky, Michael E.; Hahn, Kelly D.; Hansen, Stephanie B.; Jones, Brent M.; Knapp, Patrick K.; Martin, Matthew; Peterson, Kyle J.; Rochau, G.A.; Ruiz, Carlos L.; Schmit, Paul S.; Sinars, Daniel S.; Slutz, Stephen A.; Weis, Matthew R.; Yu, Edmund Y.

Abstract not provided.

MagLIF Pre-Heat Optimization on the PECOS Surrogacy Platform

Geissel, Matthias G.; Harvey-Thompson, Adam J.; Awe, Thomas J.; Ampleford, David A.; Bliss, David E.; Glinsky, Michael E.; Gomez, Matthew R.; Harding, Eric H.; Hansen, Stephanie B.; Jennings, Christopher A.; Kimmel, Mark W.; Knapp, Patrick K.; Lewis, Sean M.; Peterson, Kyle J.; Rambo, Patrick K.; Rochau, G.A.; Schollmeier, Marius; Shores, Jonathon S.; Sinars, Daniel S.; Slutz, Stephen A.; Smith, Ian C.; Speas, Christopher S.; Vesey, Roger A.; Weis, Matthew R.; Porter, John L.

Abstract not provided.

A 7.2 keV spherical x-ray crystal backlighter for two-frame, two-color backlighting at Sandia's Z Pulsed Power Facility

Review of Scientific Instruments

Schollmeier, Marius; Knapp, P.F.; Ampleford, David A.; Harding, Eric H.; Jennings, C.A.; Lamppa, Derek C.; Loisel, G.P.; Martin, M.R.; Robertson, Grafton K.; Shores, J.E.; Smith, Ian C.; Speas, C.S.; Weis, M.R.; Porter, John L.; McBride, Ryan D.

Many experiments on Sandia National Laboratories' Z Pulsed Power Facility - a 30 MA, 100 ns rise-time, pulsed-power driver - use a monochromatic quartz crystal backlighter system at 1.865 keV (Si Heα) or 6.151 keV (Mn Heα) x-ray energy to radiograph an imploding liner (cylindrical tube) or wire array z-pinch. The x-ray source is generated by the Z-Beamlet laser, which provides two 527-nm, 1 kJ, 1-ns laser pulses. Radiographs of imploding, thick-walled beryllium liners at convergence ratios CR above 15 [CR=ri(0)/ri(t)] using the 6.151-keV backlighter system were too opaque to identify the inner radius ri of the liner with high confidence, demonstrating the need for a higher-energy x-ray radiography system. Here, we present a 7.242 keV backlighter system using a Ge(335) spherical crystal with the Co Heα resonance line. This system operates at a similar Bragg angle as the existing 1.865 keV and 6.151 keV backlighters, enhancing our capabilities for two-color, two-frame radiography without modifying the system integration at Z. The first data taken at Z include 6.2-keV and 7.2-keV two-color radiographs as well as radiographs of low-convergence (CR about 4-5), high-areal-density liner implosions.

More Details

The Differential Absorption Hard X-Ray Spectrometer at the Z Facility

IEEE Transactions on Plasma Science

Bell, Kate S.; Coverdale, Christine A.; Ampleford, David A.; Bailey, James E.; Loisel, Guillaume P.; Harper-Slaboszewicz, V.H.; Schwarz, Jens S.; Moy, Kenneth

The differential absorption hard X-ray (DAHX) spectrometer is a diagnostic developed to measure time-resolved radiation between 60 keV and 2 MeV at the Z Facility. It consists of an array of seven Si PIN diodes in a tungsten housing that provides collimation and coarse spectral resolution through differential filters. DAHX is a revitalization of the hard X-ray spectrometer that was fielded on Z prior to refurbishment in 2006. DAHX has been tailored to the present radiation environment in Z to provide information on the power, spectral shape, and time profile of the hard emission by plasma radiation sources driven by the Z machine.

More Details

A Path to Increased Performance in Magnetized Liner Inertial Fusion

Gomez, Matthew R.; Slutz, Stephen A.; Jennings, Christopher A.; Harvey-Thompson, Adam J.; Weis, Matthew R.; Lamppa, Derek C.; Hutsel, Brian T.; Ampleford, David A.; Awe, Thomas J.; Bliss, David E.; Chandler, Gordon A.; Geissel, Matthias G.; Hahn, Kelly D.; Hansen, Stephanie B.; Harding, Eric H.; Hess, Mark H.; Knapp, Patrick K.; Laity, George R.; Martin, Matthew; Nagayama, Taisuke N.; Rovang, Dean C.; Ruiz, Carlos L.; Savage, Mark E.; Schmit, Paul S.; Schwarz, Jens S.; Smith, Ian C.; Vesey, Roger A.; Yu, Edmund Y.; Cuneo, M.E.; Jones, Brent M.; Peterson, Kyle J.; Porter, John L.; Rochau, G.A.; Sinars, Daniel S.; Stygar, William A.

Abstract not provided.

Coarse spectral characterization of warm x-rays at the Z facility using a filtered thermoluminescent dosimeter array

Review of Scientific Instruments

Harper-Slaboszewicz, V.H.; Ulmen, Benjamin A.; Parzyck, Christopher T.; Ampleford, David A.; McCourt, Andrew L.; Bell, Kate S.; Coverdale, Christine A.

A new collimated filtered thermoluminescent dosimeter (TLD) array has been developed at the Z facility to characterize warm x-rays (hν > 10 keV) produced by Z pinch radiation sources. This array includes a Kapton debris shield assembly to protect the TLDs from the source debris, a collimator array to limit the field of view of the TLDs to the source region, a filter wheel containing filters of aluminum, copper and tungsten up to 3 mm thick to independently filter each TLD, and a hermetically sealed cassette containing the TLDs as well as tungsten shielding on the sides and back of the array to minimize scattered radiation reaching the TLDs. Here experimental results from a krypton gas puff and silver wire array shot are analyzed using two different functional forms of the energy spectrum to demonstrate the ability of this diagnostic to consistently extend the upper end of the x-ray spectrum characterization from ~50 keV to >1 MeV.

More Details

Characterization of multilayer coated replicated Wolter optics for imaging X-ray emission from pulsed power

Proceedings of SPIE - The International Society for Optical Engineering

Ames, A.; Ampleford, David A.; Bourdon, C.; Bruni, R.; Kilaru, K.; Kozioziemski, B.; Pivovaroff, M.; Ramsey, B.; Romaine, S.; Vogel, J.; Walton, C.; Wu, Ming W.

We have developed a process for indirectly coating arbitrarily small diameter electroformed nickel replicated optics with multilayers to increase their response at high energy (i.e. >10 keV). The ability to fabricate small diameter multilayer coated full shell Wolter X-ray optics with narrow bandpass opens the door to several applications within astronomy and also provides a path for cross-fertilization to other fields. We report on the characterization and evaluation of the first two prototype X-ray Wolter optics to be delivered to the Z Pulsed Power Facility at Sandia National Laboratories. The intent is to develop and field several optics as part of an imaging system with targeted spectral ranges.

More Details
Results 76–100 of 273
Results 76–100 of 273