Publications

Results 26–30 of 30
Skip to search filters

Sorption of Arsenic from Drinking Water to Mg(OH)2 Sorrel's Cements, and Zirconium Doped Materials

Zhao, Hongting Z.; Sanchez, Charles A.; Larese, Kathleen C.; Salas, Fred S.; Hasan, Ahmed H.; Lucero, Daniel A.; Larese, Kathleen C.

It was discovered that MgO or Mg(OH){sub 2} when it reacts with water is a very strong sorbent for arsenic. Distribution constants, or K{sub d} values, are as high as 1 x 10{sup 6} L/mole. In this work, Mg(OH){sub 2} and other compounds have been investigated as sorbents for arsenic and other contaminants. This work has resulted in several major accomplishments including: (1) design, construction, and testing of a pressure sand filter to remove Mg(OH){sub 2} after it has sorbed arsenic from water, (2) stabilization of Mg(OH){sub 2} as a Sorrel's cement against reaction with carbonate that results in MgCO{sub 3} formation decreasing the efficiency of Mg(OH){sub 2} to sorb arsenic, and (3) the development of a new, very promising sorbent for arsenic based on zirconium. Zirconium is an environmentally benign material found in many common products such as toothpaste. It is currently used in water treatment and is very inexpensive. In this work, zirconium has been bonded to activated carbon, zeolites, sand and montmorillonite. Because of its high charge in ionic form (+6), zirconium is a strong sorbent for many anions including arsenic. In equilibrium experiments arsenic concentrations in water were reduced from 200 ppb to less than 1 ppb in less than 1 minute of contact time. Additionally, analytical methods for detecting arsenic in water have also been investigated. Various analytical techniques including HPLC, AA and ICP-MS are used for quantification of arsenic. Due to large matrix interferences HPLC and AA techniques are not very selective and are time consuming. ICP-MS is highly efficient, requires a low sample volume and has a high tolerance for interferences. All these techniques are costly and require trained staff, and with the exception of ICP-MS, these methods cannot be used at low ppb arsenic concentration without using a pre-concentration step. An alternative to these traditional techniques is to use a colorimetric method based on leucocrystal violet dye interaction with iodine. This method has been adapted in our facility for quantifying arsenic concentrations down to 14 ppb.

More Details

Evaluation of laboratory dolomite core sample size using representative elementary volume concepts

Water Resources Research

Brown, G.O.; Hsieh, H.T.; Lucero, Daniel A.

The adequacy for laboratory testing of four dolomite cores from the Culebra Dolomite of the Rustler Formation at the Waste Isolation Pilot Plant near Carlsbad, New Mexico, were evaluated using representative elementary volume (REV) theory. Gamma ray computerized tomography created three-dimensional grids of bulk density and macropore index over volumes from 1.4 x 10-7 to 1.6 L. Three different methods for both volume averaging and REV analysis were applied and compared. Both density and macropore index converged to single values with increasing volume, which meets the most common qualitative definition of a REV. Statistical test results for the relatively homogeneous samples indicate that volumes larger than 1 to 7 mL have constant properties. Contrarily, a highly varied sample required 250 and 373 mL to achieve invariant density and macropore characteristics, respectively. Prismatic volume averaging was found to be better than slice averaging, while a qualitative test for the REV provided similar results as a rigorous statistical method. All cores were larger than the REV but were significantly different from one another. This implies that multiple cores are necessary to determine the entire range of transport properties within the rock.

More Details
Results 26–30 of 30
Results 26–30 of 30