Structural evaluation of WIPP disposal room raised to Clay Seam G

Park, Byoung P.; Park, Byoung P.

This report summarizes a series of structural calculations that examine effects of raising the Waste Isolation Pilot Plant repository horizon from the original design level upward 2.43 meters. These calculations allow evaluation of various features incorporated in conceptual models used for performance assessment. Material presented in this report supports the regulatory compliance re-certification, and therefore begins by replicating the calculations used in the initial compliance certification application. Calculations are then repeated for grid changes appropriate for the new horizon raised to Clay Seam G. Results are presented in three main areas: 1. Disposal room porosity, 2. Disturbed rock zone characteristics, and 3. Anhydrite marker bed failure. No change to the porosity surface for the compliance re-certification application is necessary to account for raising the repository horizon, because the new porosity surface is essentially identical. The disturbed rock zone evolution and devolution are charted in terms of a stress invariant criterion over the regulatory period. This model shows that the damage zone does not extend upward to MB 138, but does reach MB 139 below the repository. Damaged salt would be expected to heal in nominally 100 years. The anhydrite marker beds sustain states of stress that promote failure and substantial marker bed deformation into the room assures fractured anhydrite will sustain in the proximity of the disposal rooms.