Publications

Results 76–100 of 173
Skip to search filters

Option study of an orthogonal X-ray radiography axis for pRad at LANSCE area C, Los Alamos

Oliver, Bryan V.; Leckbee, Joshua L.

We report on an option study of two potential x-ray systems for orthogonal radiography at Area C in the LANSCE facility at Los Alamos National Laboratory. The systems assessed are expected to be near equivalent systems to the presently existing Cygnus capability at the Nevada Test Site. Nominal dose and radiographic resolution of 4 rad (measured at one meter) and 1 mm spot are desired. Both a system study and qualitative design are presented as well as estimated cost and schedule. Each x-ray system analyzed is designed to drive a rod-pinch electron beam diode capable of producing the nominal dose and spot.

More Details

Absolute calibration method for fast-streaked, fiber optic light collection, spectroscopy systems

Johnston, Mark D.; Oliver, Bryan V.

This report outlines a convenient method to calibrate fast (<1ns resolution) streaked, fiber optic light collection, spectroscopy systems. Such a system is used to collect spectral data on plasmas generated in the A-K gap of electron beam diodes fielded on the RITS-6 accelerator (8-12MV, 140-200kA). On RITS, light is collected through a small diameter (200 micron) optical fiber and recorded on a fast streak camera at the output of 1 meter Czerny-Turner monochromator (F/7 optics). To calibrate such a system, it is necessary to efficiently couple light from a spectral lamp into a 200 micron diameter fiber, split it into its spectral components, with 10 Angstroms or less resolution, and record it on a streak camera with 1ns or less temporal resolution.

More Details

Advances in high intensity e-beam diode development for flash X-ray radiography

Acta Physica Polonica A

Oliver, Bryan V.; Hahn, K.; Johnston, Mark D.; Portillo, Salvador

Recent experiments at Sandia National Laboratories have demonstrated an electron beam diode X-ray source capable of producing > 350 rad at one meter with 1.7 mm FWHM X-ray source distribution, with a 50 ns pulse-width and X-ray photon endpoint energy spectrum in the 6-7 MeV range. The diode operates at current densities of ≈ 1 MA/cm2. The intense electron beam rapidly (≈ 5 ns) heats the X-ray conversion anode/target, liberating material in the form of low density ion emission early in the pulse and high density plasma later. This environment gives rise to beam/plasma collective effects which dominate the diode and beam characteristics, affecting the radiation properties (dose and spot-size). A review of the diode operation, the measured source characteristics and the simulation methods and diagnostics used to guide its optimization is given.

More Details

Load line evaluation of a 1-MV linear transformer driver (LTD)

Proceedings of the 2008 IEEE International Power Modulators and High Voltage Conference, PMHVC

Leckbee, Joshua L.; Cordova, S.; Oliver, Bryan V.; Johnson, David L.; Toury, Martial; Rosol, Rodolphe; Bui, Bill

A seven cavity LTD system has been assembled and tested in a voltage adder configuration capable of producing approximately 1-MV into a 7-Ω, critically damped load. Individual cavities have been tested with a resistive load. The seven cavity adder has been tested with a large area electron beam diode. The output pulse when tested into a resistive load is that of an RLC circuit. When tested with a dynamic load impedance, the output voltages of the cavities have an added oscillation. The oscillation affects the output pulse shape but is not harmful to the cavity components. © 2008 IEEE.

More Details

Characterization of the self magnetic pinch diode at high voltages for flash radiography

Oliver, Bryan V.; Cordova, S.

The Sandia Laboratories Advanced Radiographic Technologies Department, in collaboration with the United Kingdom Atomic Weapons Establishment, has been conducting research into the development of the Self-Magnetic-Pinched diode as an x-ray source suitable for flash radiographic experiments. We have demonstrated that this source is capable of meeting and exceeding the initial requirements of 250 rads (measured at one meter) with a 2.75 mm source spot-size. Recent experiments conducted on the RITS-6 accelerator have demonstrated the ability of this diode to meet intermediate requirements with a sub 3 mm source spot size and a dose in excess of 400 rads at one meter.

More Details

Design of a 7-MV Linear Transformer Driver (LTD) for down-hole flash x-ray radiography

Leckbee, Joshua L.; Oliver, Bryan V.

Pulsed power driven flash x-ray radiography is a valuable diagnostic for subcritical experiments at the Nevada Test Site. The existing dual-axis Cygnus system produces images using a 2.25 MV electron beam diode to produce intense x-rays from a small source. Future hydrodynamic experiments will likely use objects with higher areal mass, requiring increased x-ray dose and higher voltages while maintaining small source spot size. A linear transformer driver (LTD) is a compact pulsed power technology with applications ranging from pulsed power flash x-ray radiography to high current Z-pinch accelerators. This report describes the design of a 7-MV dual-axis system that occupies the same lab space as the Cygnus accelerators. The work builds on a design proposed in a previous report [1]. This new design provides increased diode voltage from a lower impedance accelerator to improve coupling to low impedance diodes such as the self magnetic pinch (SMP) diode. The design also improves the predicted reliability by operating at a lower charge voltage and removing components that have proven vulnerable to failure. Simulations of the new design and experimental results of the 1-MV prototype are presented.

More Details

Volumetric plasma source development and characterization

Johnston, Mark D.; Hahn, Kelly D.; Oliver, Bryan V.; Mehlhorn, Thomas A.

The development of plasma sources with densities and temperatures in the 10{sup 15}-10{sup 17} cm{sup -3} and 1-10eV ranges which are slowly varying over several hundreds of nanoseconds within several cubic centimeter volumes is of interest for applications such as intense electron beam focusing as part of the x-ray radiography program. In particular, theoretical work [1,2] suggests that replacing neutral gas in electron beam focusing cells with highly conductive, pre-ionized plasma increases the time-averaged e-beam intensity on target, resulting in brighter x-ray sources. This LDRD project was an attempt to generate such a plasma source from fine metal wires. A high voltage (20-60kV), high current (12-45kA) capacitive discharge was sent through a 100 {micro}m diameter aluminum wire forming a plasma. The plasma's expansion was measured in time and space using spectroscopic techniques. Lineshapes and intensities from various plasma species were used to determine electron and ion densities and temperatures. Electron densities from the mid-10{sup 15} to mid-10{sup 16} cm{sup -3} were generated with corresponding electron temperatures of between 1 and 10eV. These parameters were measured at distances of up to 1.85 cm from the wire surface at times in excess of 1 {micro}s from the initial wire breakdown event. In addition, a hydrocarbon plasma from surface contaminants on the wire was also measured. Control of these contaminants by judicious choice of wire material, size, and/or surface coating allows for the ability to generate plasmas with similar density and temperature to those given above, but with lower atomic masses.

More Details
Results 76–100 of 173
Results 76–100 of 173