Publications

11 Results
Skip to search filters

Shock margin testing of a one-axis MEMS accelerometer

Parson, Ted B.; Buchheit, Thomas E.

Shock testing was performed on a selected commercial-off-the-shelf - MicroElectroMechanical System (COTS-MEMS) accelerometer to determine the margin between the published absolute maximum rating for shock and the 'measured' level where failures are observed. The purpose of this testing is to provide baseline data for isolating failure mechanisms under shock and environmental loading in a representative device used or under consideration for use within systems and assemblies of the DOD/DOE weapons complex. The specific device chosen for this study was the AD22280 model of the ADXL78 MEMS Accelerometer manufactured by Analog Devices Inc. This study focuses only on the shock loading response of the device and provides the necessary data for adding influence of environmental exposure to the reliability of this class of devices. The published absolute maximum rating for acceleration in any axis was 4000 G for this device powered or unpowered. Results from this study showed first failures at 8000 G indicating a margin of error of two. Higher shock level testing indicated that an in-plane, but off-axis acceleration was more damaging than one in the sense direction.

More Details

Mechanical properties of anodized coatings over molten aluminum alloy

Journal of Colloid and Interface Science

Grillet, Anne M.; Gorby, Allen D.; Trujillo, Steven M.; Grant, Richard P.; Hodges, Vernon C.; Parson, Ted B.; Grasser, Thomas W.

A method to measure interfacial mechanical properties at high temperatures and in a controlled atmosphere has been developed to study anodized aluminum surface coatings at temperatures where the interior aluminum alloy is molten. This is the first time that the coating strength has been studied under these conditions. We have investigated the effects of ambient atmosphere, temperature, and surface finish on coating strength for samples of aluminum alloy 7075. Surprisingly, the effective Young's modulus or strength of the coating when tested in air was twice as high as when samples were tested in an inert nitrogen or argon atmosphere. Additionally, the effective Young's modulus of the anodized coating increased with temperature in an air atmosphere but was independent of temperature in an inert atmosphere. The effect of surface finish was also examined. Sandblasting the surface prior to anodization was found to increase the strength of the anodized coating with the greatest enhancement noted for a nitrogen atmosphere. Machining marks were not found to significantly affect the strength.

More Details

Acceleration of dormant storage effects to address the reliability of silicon surface micromachined Micro-Electro-Mechanical Systems (MEMS)

Walraven, J.A.; Cox, James C.; Skousen, Troy J.; Ohlhausen, J.A.; Jenkins, Mark W.; Jokiel, Bernhard J.; Parson, Ted B.; Tang, Michelle D.

Qualification of microsystems for weapon applications is critically dependent on our ability to build confidence in their performance, by predicting the evolution of their behavior over time in the stockpile. The objective of this work was to accelerate aging mechanisms operative in surface micromachined silicon microelectromechanical systems (MEMS) with contacting surfaces that are stored for many years prior to use, to determine the effects of aging on reliability, and relate those effects to changes in the behavior of interfaces. Hence the main focus was on 'dormant' storage effects on the reliability of devices having mechanical contacts, the first time they must move. A large number ({approx}1000) of modules containing prototype devices and diagnostic structures were packaged using the best available processes for simple electromechanical devices. The packaging processes evolved during the project to better protect surfaces from exposure to contaminants and water vapor. Packages were subjected to accelerated aging and stress tests to explore dormancy and operational environment effects on reliability and performance. Functional tests and quantitative measurements of adhesion and friction demonstrated that the main failure mechanism during dormant storage is change in adhesion and friction, precipitated by loss of the fluorinated monolayer applied after fabrication. The data indicate that damage to the monolayer can occur at water vapor concentrations as low as 500 ppm inside the package. The most common type of failure was attributed to surfaces that were in direct contact during aging. The application of quantitative methods for monolayer lubricant analysis showed that even though the coverage of vapor-deposited monolayers is generally very uniform, even on hidden surfaces, locations of intimate contact can be significantly depleted in initial concentration of lubricating molecules. These areas represent defects in the film prone to adsorption of water or contaminants that can cause movable structures to adhere. These analysis methods also indicated significant variability in the coverage of lubricating molecules from one coating process to another, even for identical processing conditions. The variability was due to residual molecules left in the deposition chamber after incomplete cleaning. The coating process was modified to result in improved uniformity and total coverage. Still, a direct correlation was found between the resulting static friction behavior of MEMS interfaces, and the absolute monolayer coverage. While experimental results indicated that many devices would fail to start after aging, the modeling approach used here predicted that all the devices should start. Adhesion modeling based upon values of adhesion energy from cantilever beams is therefore inadequate. Material deposition that bridged gaps was observed in some devices, and potentially inhibits start-up more than the adhesion model indicates. Advances were made in our ability to model MEMS devices, but additional combined experimental-modeling studies will be needed to advance the work to a point of providing predictive capability. The methodology developed here should prove useful in future assessments of device aging, however. Namely, it consisted of measuring interface properties, determining how they change with time, developing a model of device behavior incorporating interface behavior, and then using the age-aware interface behavior model to predict device function.

More Details

Experimental apparatus and software design for dynamic long-term reliability testing of a spring-mass MEMS device

Proceedings of SPIE - The International Society for Optical Engineering

Reu, Phillip L.; Tanner, Danelle M.; Epp, David E.; Parson, Ted B.; Boyce, Brad B.

Long-term reliability testing of Micro-Electro-Mechanical Systems (MEMS) is important to the acceptance of these devices for critical and high-impact applications. In order to make predictions on aging mechanisms, these validation experiments must be performed in controlled environments. Additionally, because the aging acceleration factors are not understood, the experiments can last for months. This paper describes the design and implementation of a long-term MEMS reliability test bed for accelerated life testing. The system is comprised of a small environmental chamber mounted on an electrodynamic shaker with a laser Doppler vibrometer (LDV) and digital camera for data collection. The humidity and temperature controlled chamber has capacity for 16 MEMS components in a 4×4 array. The shaker is used to dynamically excite the devices using broadband noise, chirp or any other programmed signal via the control software. Driving amplitudes can be varied to maintain the actuation of the test units at the desired level. The actuation is monitored optically via the LDV which can report the displacement or velocity information of the surface. A springmass accelerated aging experiment was started using a controlled environment of 5000 ppmv humidity (roughly 13% at room temperature), temperature of 29 °C, and ±80μm maximum displacement of the mass. During the first phase of the experiment, the resonant frequency was measured every 2 hours. From 114.5 to 450 hours under stress, measurements were taken every 12 hours and after that every 24 hours. Resonant frequency tracking indicates no changes in the structures for 4200 hours of testing.

More Details
11 Results
11 Results