Publications

Results 1–25 of 71
Skip to search filters

Anisotropy evolution of elastomeric foams during uniaxial compression measured via in-situ X-ray computed tomography

Materialia

Bolintineanu, Dan S.; Waymel, Robert W.; Collis, Henry H.; Long, Kevin N.; Quintana, Enrico C.; Kramer, Sharlotte L.

We have characterized the three-dimensional evolution of microstructural anisotropy of a family of elastomeric foams during uniaxial compression via in-situ X-ray computed tomography. Flexible polyurethane foam specimens with densities of 136, 160 and 240 kg/m3 were compressed in uniaxial stress tests both parallel and perpendicular to the foam rise direction, to engineering strains exceeding 70%. The uncompressed microstructures show slightly elongated ellipsoidal pores, with elongation aligned parallel to the foam rise direction. The evolution of this microstructural anisotropy during deformation is quantified based on the autocorrelation of the image intensity, and verified via the mean intercept length as well as the shape of individual pores. Trends are consistent across all three methods. In the rise direction, the material remains transversely anisotropic throughout compression. Anisotropy initially decreases with compression, reaches a minimum, then increases up to large strains, followed by a small decrease in anisotropy at the largest strains as pores collapse. Compression perpendicular to the foam rise direction induces secondary anisotropy with respect to the compression axis, in addition to primary anisotropy associated with the foam rise direction. In contrast to compression in the rise direction, primary anisotropy initially increases with compression, and shows a slight decrease at large strains. These surprising non-monotonic trends and qualitative differences in rise and transverse loading are explained based on the compression of initially ellipsoidal pores. Microstructural anisotropy trends reflect macroscopic stress-strain and lateral strain response. These findings provide novel quantitative connections between three-dimensional microstructure and anisotropy in moderate density polymer foams up to large deformation, with important implications for understanding complex three-dimensional states of deformation.

More Details

Thermal-Mechanical Elastic-Plastic and Ductile Failure Model Calibrations for 6061-T651 Aluminum Alloy from Plate

Corona, Edmundo C.; Kramer, Sharlotte L.; Lester, Brian T.; Jones, Amanda; Sanborn, Brett S.; Fietek, Carter J.

Numerical simulations of metallic structures undergoing rapid loading into the plastic range require material models that accurately represent the response. In general, the material response can be seen as having four interrelated parts: the baseline response under slow loading, the effect of strain rate, the conversion of plastic work into heat and the effect of temperature. In essence, the material behaves in a thermal-mechanical manner if the loading is fast enough so when heat is generated by plastic deformation it raises the temperature and therefore influences the mechanical response. In these cases, appropriate models that can capture the aspects listed above are necessary. The matters of interest here are the elastic-plastic response and ductile failure behavior of 6061-T651 aluminum alloy under the conditions described above. The work was accomplished by first designing and conducting a material test program to provide data for the calibration of a modular $J_2$ plasticity model with isotropic hardening as well as a ductile failure model. Both included modules that accounted for temperature and strain rate dependence. The models were coupled with an adiabatic heating module to calculate the temperature rise due to the conversion of plastic work to heat. The test program included uniaxial tension tests conducted at room temperature, 150 and 300 C and at strain rates between 10–4 and 103 1/s as well as four geometries of notched tension specimens and two tests on specimens with shear-dominated deformations. The test data collected allowed the calibration of both the plasticity and the ductile failure models. Most test specimens were extracted from a single piece of plate to maintain consistency. Notched tension tests came from a possibly different plate, but from the same lot. When using the model in structural finite element calculations, element formulations and sizes different from those used to model the test specimens in the calibration are likely to be used. A brief investigation demonstrated that the failure model can be particularly sensitive to the element selection and provided an initial guide to compensate in a specific example.

More Details

Anisotropic plasticity model forms for extruded Al 7079: Part II, validation

International Journal of Solids and Structures

Jones, Elizabeth M.; Corona, Edmundo C.; Jones, Amanda; Scherzinger, William M.; Kramer, Sharlotte L.

This is the second part of a two-part contribution on modeling of the anisotropic elastic-plastic response of aluminum 7079 from an extruded tube. Part I focused on calibrating a suite of yield and hardening functions from tension test data; Part II concentrates on evaluating those calibrations. Here, a rectangular validation specimen with a blind hole was designed to provide heterogeneous strain fields that exercise the material anisotropy, while at the same time avoiding strain concentrations near sample edges where Digital Image Correlation (DIC) measurements are difficult to make. Specimens were extracted from the tube in four different orientations and tested in tension with stereo-DIC measurements on both sides of the specimen. Corresponding Finite Element Analysis (FEA) with calibrated isotropic (von Mises) and anisotropic (Yld2004-18p) yield functions were also conducted, and both global force-extension curves as well as full-field strains were compared between the experiments and simulations. Specifically, quantitative full-field strain error maps were computed using the DIC-leveling approach proposed by Lava et al. The specimens experienced small deviations from ideal boundary conditions in the experiments, which had a first-order effect on the results. Therefore, the actual experimental boundary conditions had to be applied to the FEA in order to make valid comparisons. The predicted global force-extension curves agreed well with the measurements overall, but were sensitive to the boundary conditions in the nonlinear regime and could not differentiate between the two yield functions. Interrogation of the strain fields both qualitatively and quantitatively showed that the Yld2004-18p model was clearly able to better describe the strain fields on the surface of the specimen compared to the von Mises model. These results justify the increased complexity of the calibration process required for the Yld2004-18p model in applications where capturing the strain field evolution accurately is important, but not if only the global force-extension response of the elastic–plastic region is of interest.

More Details

Thermal-Mechanical Elastic-Plastic and Ductile Failure Model Calibrations for 304L Stainless Steel Alloy

Corona, Edmundo C.; Kramer, Sharlotte L.; Lester, Brian T.; Jones, Amanda; Sanborn, Brett S.; Shand, Lyndsay S.; Fietek, Carter J.

Numerical simulations of metallic structures undergoing rapid loading into the plastic range require material models that accurately represent the response. In general, the material response can be seen as having four interrelated parts: the baseline response under slow loading, the effect of strain rate, the conversion of plastic work into heat and the effect of temperature. In essence, the material behaves in a thermal-mechanical manner if the loading is fast enough so when heat is generated by plastic deformation it raises the temperature and therefore influences the mechanical response. In these cases, appropriate models that can capture the aspects listed above are necessary. The material of interest here is 304L stainless steel, and the objective of this work is to calibrate thermal-mechanical models: one for the constitutive behavior and another for failure. The work was accomplished by first designing and conducting a material test program to provide data for the calibration of the models. The test program included uniaxial tension tests conducted at room temperature, 150 and 300 C and at strain rates between 10–4 and 103 1/s. It also included notched tension and shear-dominated compression hat tests specifically designed to calibrate the failure model. All test specimens were extracted from a single piece of plate to maintain consistency. The constitutive model adopted was a modular $J_2$ plasticity model with isotropic hardening that included rate and temperature dependence. A criterion for failure initiation based on a critical value of equivalent plastic strain fitted the failure data appropriately and was adopted. Possible ranges of the values of the parameters of the models were determined partially on historical data from calibrations of the same alloy from other lots and are given here. The calibration of the parameters of the models were based on finite element simulations of the various material tests using relatively ne meshes and hexahedral elements. When using the model in structural finite element calculations, however, element formulations and sizes different from those in the calibration are likely to be used. A brief investigation demonstrated that the failure initiation predictions can be particularly sensitive to the element selection and provided an initial guide to compensate for the effect of element size in a specific example.

More Details

Exploring Microstructural Descriptors in Elastomeric Foams Using Digital Image Correlation and Statistical Analysis

Conference Proceedings of the Society for Experimental Mechanics Series

Waymel, Robert W.; Kramer, Sharlotte L.; Bolintineanu, Dan S.; Quintana, Enrico C.; Long, Kevin N.

In this work, we investigated microstructural features of elastomeric foam with the goal of identifying descriptors other than porosity that have a significant effect on the macroscale mechanical response. X-ray computed tomography (XCT) provided three-dimensional images of several flexible polyurethane foam samples prior to mechanical testing. The samples were then compressed to approximately 80% engineering strain. Stereo digital image correlation was used to measure the three-dimensional surface displacement data, from which strain was determined. The strain data, which were calculated with respect to the undeformed coordinates, were then overlaid on the corresponding surface generated from XCT. Heterogeneities in the strain-field were cross-correlated with topological quantities such as pore size distribution. A statistically significant correlation was identified between the distance transform of the pore phase and strain fluctuations.

More Details
Results 1–25 of 71