Publications

9 Results
Skip to search filters

100 GW linear transformer driver cavity: Design, simulations, and performance

Physical Review Accelerators and Beams

Douglass, Jonathan D.; Hutsel, Brian T.; Leckbee, Joshua L.; Mulville, Thomas D.; Stoltzfus, Brian S.; Savage, Mark E.; Breden, E.W.; Calhoun, Jacob D.; Cuneo, M.E.; De Smet, Dennis J.; Hohlfelder, Robert J.; Jaramillo, Deanna M.; Johns, Owen J.; Lombrozo, Aaron C.; Lucero, Diego J.; Moore, James M.; Porter, John L.; Radovich, S.; Sceiford, Matthew S.; Sullivan, Michael A.; Walker, Charles A.; Yazzie, Nicole T.

Here we present details of the design, simulation, and performance of a 100-GW linear transformer driver (LTD) cavity at Sandia National Laboratories. The cavity consists of 20 “bricks.” Each brick is comprised of two 80 nF, 100 kV capacitors connected electrically in series with a custom, 200 kV, three-electrode, field-distortion gas switch. The brick capacitors are bipolar charged to ±100 kV for a total switch voltage of 200 kV. Typical brick circuit parameters are 40 nF capacitance (two 80 nF capacitors in series) and 160 nH inductance. The switch electrodes are fabricated from a WCu alloy and are operated with breathable air. Over the course of 6,556 shots the cavity generated a peak electrical current and power of 1.03 MA (±1.8%) and 106 GW (±3.1%). Experimental results are consistent (to within uncertainties) with circuit simulations for normal operation, and expected failure modes including prefire and late-fire events. New features of this development that are reported here in detail include: (1) 100 ns, 1 MA, 100-GW output from a 2.2 m diameter LTD into a 0.1 Ω load, (2) high-impedance solid charging resistors that are optimized for this application, and (3) evaluation of maintenance-free trigger circuits using capacitive coupling and inductive isolation.

More Details

Pulsed-coil magnet systems for applying uniform 10-30 T fields to centimeter-scale targets on Sandia's Z facility

Review of Scientific Instruments

Rovang, Dean C.; Lamppa, Derek C.; Cuneo, M.E.; Owen, A.C.; Mckenney, John M.; Johnson, Drew J.; Radovich, S.; Kaye, Ronald J.; McBride, Ryan D.; Alexander, Charles S.; Awe, T.J.; Slutz, S.A.; Sefkow, Adam B.; Haill, Thomas A.; Jones, Peter A.; Argo, J.W.; Dalton, D.G.; Robertson, Grafton K.; Waisman, Eduardo M.; Sinars, Daniel S.; Meissner, J.; Milhous, M.; Nguyen, D.N.; Mielke, C.H.

Sandia has successfully integrated the capability to apply uniform, high magnetic fields (10-30 T) to high energy density experiments on the Z facility. This system uses an 8-mF, 15-kV capacitor bank to drive large-bore (5 cm diameter), high-inductance (1-3 mH) multi-turn, multi-layer electromagnets that slowly magnetize the conductive targets used on Z over several milliseconds (time to peak field of 2-7 ms). This system was commissioned in February 2013 and has been used successfully to magnetize more than 30 experiments up to 10 T that have produced exciting and surprising physics results. These experiments used split-magnet topologies to maintain diagnostic lines of sight to the target. We describe the design, integration, and operation of the pulsed coil system into the challenging and harsh environment of the Z Machine. We also describe our plans and designs for achieving fields up to 20 T with a reduced-gap split-magnet configuration, and up to 30 T with a solid magnet configuration in pursuit of the Magnetized Liner Inertial Fusion concept.

More Details
9 Results
9 Results