Automatic test system for lifetime testing of 100 kilovolt scyllac-style energy storage capacitors

Digest of Technical Papers-IEEE International Pulsed Power Conference

Savage, Mark E.; Starbird, R.; Ziska, G.; Sharpe, R.

Optimizing the design of the upgrade to the Z pulser at Sandia National Laboratories renewed interest in the ubiquitous Scyllac-cased capacitor. For the Z upgrade, the desired capacitance value in each case is different than those built before, and double that of the existing units in Z. The cost and fundamental importance of the Marx capacitors in pulsers like Z prompted the decision to build a test facility that could evaluate sample units from capacitor manufacturers. The number of interested vendors and the expected lifetime indicated about 350 thousand capacitor-shots for the capacitors in a plus-minus configuration. The project schedule demanded that the initial testing be completed in a few months. These factors, and budget limitations, pointed to the need for a system that could test multiple pairs of capacitors at once, without a full-time attendant. The system described here tests up to ten pairs of 2.6 μF capacitors charged to 100 kV in 90 seconds, then discharged at 150 kA and 35 percent reversal. Unattended operation requires sophisticated fault detection, and so much attention has been paid to this. This paper will describe the system, and the key components including the control system, the switches, and the load resistors. The paper will also show some lifetime and performance data from commonly used 200 kV spark gap switches.