Systems Analysis, Simulation, and Signal Processing Aspects of Coordinated Experimental and Modeling Investigations of Gas Discharge Switch Breakdown and Energy Loss Behavior
Abstract not provided.
Abstract not provided.
A measurement system's components: cabling, delay line, waveform recorder, etc., degrade acquired signals and their respective bandlimited frequency responses. Compensation software corrects for this frequency-dependent spectral degradation by deconvolving the transfer function of the entire measurement system out of the measured signal spectra. This report describes methods to transfer the characteristics of a wide bandwidth repetitive sampling oscilloscope to a single-shot transient digitizer, characterize the measurement system, develop a cascaded transition-band filter, and compensate data acquired with the filtered, characterized measurement system. These procedures are easily implemented, execute quickly, and successfully compensate waveforms possessing endpoint discontinuities. Waveforms possessing endpoint discontinuities are made to appear duration-limited and continuous. The spectra for these modified waveforms are correct, including at dc. The deconvolution process introduces unavoidable noise. Filtering is applied to reduce the deconvolution noise while minimally affecting compensated waveform risetime and amplitude. Resultant compensated data retains its initial dc baseline offset with improved waveform fidelity and low noise of deconvolution.