Publications

Results 1–50 of 73
Skip to search filters

Deployment of a double scatter system for directional detection of background neutron radiation

Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

Glick, Adam; Brubaker, Erik B.; Cabrera-Palmer, Belkis C.; Gerling, Mark D.; Quiter, Brian J.; Vetter, Kai

The detection of special nuclear materials (SNM) requires the understanding of nuclear signatures that allow the discrimination against background. In particular, understanding neutron background characteristics such as count rates and energies and their correlations with environmental conditions and surroundings of measurement locations is important in enhancing SNM detection capabilities. The Mobile Imager of Neutrons for Emergency Responders (MINER) was deployed for 8 weeks in downtown San Francisco (CA) to study such neutron background characteristics in an urban environment. Of specific interest was the investigation of the impact of surrounding buildings on the neutron background count rates and to answer the question whether buildings act as absorber of neutrons or as sources via the so-called ship effect. MINER consists of 16 liquid scintillator detector elements and can be operated as a neutron spectrometer, as a neutron imager, or simply as a counter of fast neutrons. As expected, the neutron background rate was found to be inversely proportional to the atmospheric pressure. In the energy range where MINER is most sensitive, approximately 1–10 MeV, it was found that the shape of the detected background spectrum is similar to that of a detected fission spectrum, indicating the limited discrimination power of the neutron energy. The similarities between the detected background neutron spectrum and fission sources makes it difficult to discriminate SNM from background based solely on the energies observed. The images produced using maximum likelihood expectation maximization revealed that neutrons preferentially are coming from areas in the environment that have open sky, indicating that the surrounding buildings act as absorbers of neutrons rather than sources as expected by the ship effect. The inherent properties of a neutron scatter camera limit the achievable image quality and the effective deployment to systematically map neutron background signatures due to the low count rate.

More Details

Extension of the neutron scatter camera sensitivity to the ∼ 10-200 MeV neutron energy range

Review of Scientific Instruments

Cabrera-Palmer, Belkis C.; Brubaker, Erik B.; Gerling, Mark D.; Reyna, David R.

The Neutron Scatter Camera (NSC) is a neutron spectrometer and imager that has been developed and improved by the Sandia National Laboratories for several years. Built for special nuclear material searches, the instrument was configured by the design to reconstruct neutron sources within the fission energy range 1-10 MeV. In this work, we present modifications that attempt to extend the NSC sensitivity to neutron energies in the range ∼10-200 MeV and discuss the corresponding consequences for the event processing. We present simulation results that manifest important aspects of the NSC response to those intermediate energy neutrons. The simulation results also evidence that the instrument's spectroscopic capabilities severely deteriorate at those energies, mainly due to the uncertainties in measuring energy, time, and distance between the two neutron scattering interactions. This work is motivated by the need to characterize neutron fluxes at particle accelerators as they may represent important backgrounds for neutrino experiments.

More Details

Feasibility of Single-sided 3D elemental imaging

Sweany, Melinda; Gerling, Mark D.; Marleau, Peter M.; Monterial, Mateusz M.

We present single-sided 3D image reconstruction and neutron spectrum of non-nuclear material interrogated with a deuterium-tritium neutron generator. The results presented here are a proof-of-principle of an existing technique previously used for nuclear material, applied to non-nuclear material. While we do see excess signatures over background, they do not have the expected form and are currently un-identified.

More Details

Source detection at 100 meter standoff with a time-encoded imaging system

Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

Brennan, James S.; Brubaker, Erik B.; Gerling, Mark D.; Marleau, Peter M.; Monterial, Mateusz M.; Nowack, A.; Schuster, P.; Sturm, B.; Sweany, Melinda

We present the design, characterization, and testing of a laboratory prototype radiological search and localization system. The system, based on time-encoded imaging, uses the attenuation signature of neutrons in time, induced by the geometrical layout and motion of the system. We have demonstrated the ability to detect a ∼1mCi252Cf radiological source at 100m standoff with 90% detection efficiency and 10% false positives against background in 12min. This same detection efficiency is met at 15s for a 40m standoff, and 1.2s for a 20m standoff.

More Details

Additional capabilities of a compact neutron scatter camera: Active interrogation, time-correlated pulse-height multiplication measurements, and gamma imaging

2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2015

Goldsmith, John E.; Brennan, James S.; Gerling, Mark D.; Marleau, Peter M.; Monterial, Mateusz M.

Our previous conference report on this instrument emphasized its use for fast-neutron imaging spectroscopy. We describe here its additional measurement capabilities, namely active interrogation, time-correlated pulse-height multiplication measurements, and gamma imaging.

More Details

System Construction of the Stilbene Compact Neutron Scatter Camera

Goldsmith, John E.; Gerling, Mark D.; Brennan, James S.; Throckmorton, Daniel J.; Helm, Jonathan I.

This report documents the construction of a stilbene-crystal-based compact neutron scatter camera. This system is essentially identical to the MINER (Mobile Imager of Neutrons for Emergency Responders) system previously built and deployed under DNN R&D funding,1 but with the liquid scintillator in the detection cells replaced by stilbene crystals. The availability of these two systems for side-by-side performance comparisons will enable us to unambiguously identify the performance enhancements provided by the stilbene crystals, which have only recently become commercially available in the large size required (3” diameter, 3” deep).

More Details

MINER - A mobile imager of neutrons for emergency responders

2014 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014

Gerling, Mark D.; Goldsmith, John E.; Brennan, James S.

Our research group has been developing a fast neutron imaging platform to enhance the capabilities of emergency responders in the localization and characterization of special nuclear material. This mobile imager of neutrons for emergency responders (MINER) is a compact neutron scatter camera optimized to provide omni-directional (4-Pi) imaging with only a ~twofold decrease in sensitivity compared to our much larger neutron scatter cameras. The system performance is tuned for fission energy neutron imaging and spectroscopy, and it also can function as a Compton camera for gamma imaging. Results will be presented relating to detector response as well as several measurement campaigns at external facilities.

More Details

Demonstration of two-dimensional time-encoded imaging of fast neutrons

Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

Brennan, James S.; Brubaker, Erik B.; Gerling, Mark D.; Marleau, Peter M.; McMillan, K.; Nowack, A.; Galloudec, N.R.; Sweany, Melinda

We present a neutron detector system based on time-encoded imaging, and demonstrate its applicability toward the spatial mapping of special nuclear material. We demonstrate that two-dimensional fast-neutron imaging with 2° resolution at 2 m stand-off is feasible with only two instrumented detectors.

More Details

A High-Sensitivity Fast Neutron Imager

Goldsmith, John E.; Brennan, James S.; Brubaker, Erik B.; Cabrera-Palmer, Belkis C.; Gerling, Mark D.; Marleau, Peter M.; Mascarenhas, Nick M.; Reyna, David R.

A wide range of NSC (Neutron Scatter Camera) activities were conducted under this lifecycle plan. This document outlines the highlights of those activities, broadly characterized as system improvements, laboratory measurements, and deployments, and presents sample results in these areas. Additional information can be found in the documents that reside in WebPMIS.

More Details

MINER - A Mobile Imager of Neutrons for Emergency Responders

Goldsmith, John E.; Brennan, James S.; Gerling, Mark D.; Kiff, Scott D.; Mascarenhas, Nick M.; Van De Vreugde, James L.

We have developed a mobile fast neutron imaging platform to enhance the capabilities of emergency responders in the localization and characterization of special nuclear material. This mobile imager of neutrons for emergency responders (MINER) is based on the Neutron Scatter Camera, a large segmented imaging system that was optimized for large-area search applications. Due to the reduced size and power requirements of a man-portable system, MINER has been engineered to fit a much smaller form factor, and to be operated from either a battery or AC power. We chose a design that enabled omnidirectional (4π) imaging, with only a ~twofold decrease in sensitivity compared to the much larger neutron scatter cameras. The system was designed to optimize its performance for neutron imaging and spectroscopy, but it does also function as a Compton camera for gamma imaging. This document outlines the project activities, broadly characterized as system development, laboratory measurements, and deployments, and presents sample results in these areas. Additional information can be found in the documents that reside in WebPMIS.

More Details

Results from laboratory tests of the two-dimensional Time-Encoded Imaging System

Marleau, Peter M.; Brennan, James S.; Brubaker, Erik B.; Gerling, Mark D.; Le Galloudec, Nathalie J.

A series of laboratory experiments were undertaken to demonstrate the feasibility of two dimensional time-encoded imaging. A prototype two-dimensional time encoded imaging system was designed and constructed. Results from imaging measurements of single and multiple point sources as well as extended source distributions are presented. Time encoded imaging has proven to be a simple method for achieving high resolution two-dimensional imaging with potential to be used in future arms control and treaty verification applications.

More Details

Multi-depth Measurement of Fast Neutrons

Marleau, Peter M.; Gerling, Mark D.; Sweany, Melinda; Cabrera-Palmer, Belkis C.; Brennan, James S.

A spallation based multiplicity detector has been constructed and deployed to the Kimballton Underground Research Facility to measure the cosmogenic fast neutron flux anti-coincident from the initiating muon. Two of the three planned measurements have been completed ( ,,, 380 and , -- , 600 m.w.e) with sufficient statistics. The third measurement at level 14 (-4450 m.w.e.) is currently being performed. Current results at - , 600 m.w.e. compare favourably to the one previous measurement at 550 m.w.e. For neutron energies between 100 and 200 MeV measurements at , -- , 380 m.w.e. produce fluxes between 1e -8 and 7e -9 n/cm 2 /s/MeV and at , - , 600 m.w.e. measurements produce fluxes between 7e -9 and 1e- 11 n/cm2 /s/MeV.

More Details
Results 1–50 of 73
Results 1–50 of 73