Combined Imaging and RNA-Seq on a Microfluidic Platform for Viral Infection Studies

Krishnakumar, Raga K.; Sjoberg, Kurt C.; Fisher, Andrew N.; Doudoukjian, Gloria E.; Webster, Elizabeth W.

The goal of this work was to pioneer a novel, low-overhead protocol for simultaneously assaying cell-surface markers and intracellular gene expression in a single mammalian cell. The purpose of developing such a method is to be able to understand the mechanisms by which pathogens engage with individual mammalian cells, depending on their cell surface proteins, and how both host and pathogen gene expression changes are reflective of these mechanisms. The knowledge gained from such analyses of single cells will ultimately lead to more robust pathogen detection and countermeasures. Our method was aimed at streamlining both the upstream cell sample preparation using microfluidic methods, as well as the actual library making protocol. Specifically, we wanted to implement a random hexamer-based reverse transcription of all RNA within a single cell (as opposed to oligo dT-based which would only capture polyadenylated transcripts), and then use a CRISPR-based method called scDash to deplete ribosomal DNAs (since ribosomal RNAs make up the majority of the RNA in a mammalian cell). After significant troubleshooting, we demonstrate that we are able to prepare cDNA from RNA using the random hexamer primer, and perform the rDNA depletion. We also show that we can visualize individually stained cells, setting up the pipeline for connecting surface markers to RNA-sequencing profiles. Finally, we test a number of devices for various parts of the pipeline, including bead generation, optical barcoding and cell dispensing, and demonstrate that while some of these have potential, more work is needed to optimize this part of the pipeline.

More Details

System Response Characterization for a d–t Neutron Radiography System

Sweany, Melinda; Weinfurther, Kyle J.; Sjoberg, Kurt C.; Marleau, Peter M.

We report the system response of a pixelated associated particle imaging (API) neutron radiography system. The detector readout currently consists of a 2x2 array of organic glass scintillator detectors, each with an 8x8 array of optically isolated pixels that match the size and pitch of the ARRAYJ-60035-64P-PCB Silicon Photomultiplier (SiPM) array from SensL/onsemi with 6x6 mm2 SiPMs. The alpha screen of the API deuterium-tritium neutron generator is read out with the S13361-3050AE-08 from Hamamatsu, which is an 8x8 array of 3x3 mm2 SiPMs. Data from the 320 channel system is acquired with the TOFPET2-based readout system. We present the predicted imaging capability of an eventual 5x5 detector array, the waveform-based energy and pulse shape characterization of the individual detectors, and the timing and energy response from the TOFPET2 system.

More Details
3 Results
3 Results