Thunder Range Shock Incident Technical Advisory Team Investigation
Abstract not provided.
Abstract not provided.
IEEE Transactions on Plasma Science
This paper discusses the penetration and coupling of a lightning return stroke through a hole in a metal barrier to a conductor located behind the hole. Indirect field coupling (electric and magnetic) and direct discharges are considered both analytically and experimentally. Although here we consider the hole to be preexisting, one application of this work is lightning return stroke coupling through holes burned in metallic barriers by the continuing current component of lightning. The goal is to develop an understanding of the mechanisms and expected penetrant levels in lightning burnthrough. © 2011 IEEE.
A lightning flash consists of multiple, high-amplitude but short duration return strokes. Between the return strokes is a lower amplitude, continuing current which flows for longer duration. If the walls of a Faraday cage are made of thin enough metal, the continuing current can melt a hole through the metal in a process called burnthrough. A subsequent return stroke can couple energy through this newly-formed hole. This LDRD is a study of the protection provided by a Faraday cage when it has been compromised by burnthrough. We initially repeated some previous experiments and expanded on them in terms of scope and diagnostics to form a knowledge baseline of the coupling phenomena. We then used a combination of experiment, analysis and numerical modeling to study four coupling mechanisms: indirect electric field coupling, indirect magnetic field coupling, conduction through plasma and breakdown through the hole. We discovered voltages higher than those encountered in the previous set of experiments (on the order of several hundreds of volts).
IEEE Transactions on EMC
Abstract not provided.
Linear lightning diffusion into a Faraday cage is studied. An early-time integral valid for large ratios of enclosure size to enclosure thickness and small relative permeability ({mu}/{mu}{sub 0} {le} 10) is used for this study. Existing solutions for nearby lightning impulse responses of electrically thick-wall enclosures are refined and extended to calculate the nearby lightning magnetic field (H) and time-derivative magnetic field (HDOT) inside enclosures of varying thickness caused by a decaying exponential excitation. For a direct strike scenario, the early-time integral for a worst-case line source outside the enclosure caused by an impulse is simplified and numerically integrated to give the interior H and HDOT at the location closest to the source as well as a function of distance from the source. H and HDOT enclosure response functions for decaying exponentials are considered for an enclosure wall of any thickness. Simple formulas are derived to provide a description of enclosure interior H and HDOT as well. Direct strike voltage and current bounds for a single-turn optimally-coupled loop for all three waveforms are also given.
Abstract not provided.
Simple formulas are given for the interior voltages appearing across bolted joints from exterior lightning currents. External slot and bolt inductances as well as internal slot and bolt diffusion effects are included. Both linear and ferromagnetic wall materials are considered. A useful simplification of the slot current distribution into linear stripline and cylindrical parts (near the bolts) allows the nonlinear voltages to be estimated in closed form.
Proposed for publication in the Journal of Electrostatics.
By using a multipole-conformal mapping expansion for the wire currents we examine the accuracy of approximations for the transfer inductance of a one dimensional array of wires (wire grid). A simple uniform fit is constructed by introduction of the decay factor from bipolar coordinates into existing formulas for this inductance.
On September 24, 25, 28, and 29, 1998 and on October 19 and 23, 1998, transfer impedance measurements were made on Los Alamos National Laboratories TA 16 - Building 411 and TA 8-- Building 23 to characterize their interior open-circuit voltage response to a direct lightning flash attachment to the structures. The theory, history, measurement methods and equipment, and specific measured results are detailed. The measured results demonstrate that if the remaining metallic penetrations are bonded, then the rebar of the two structures is sufficiently well connected to form a Faraday cage that reduces the maximum open-circuit voltage inside the structure to a sufficiently low level that the required standoff distance to prevent arcing to explosive assemblies is 6.8 inches for TA 16 - Building 411 and is 11.5 inches for TA 8 - Building 23.
This report summarizes the effort to quantify the electromagnetic environments in the nuclear explosive areas at Pantex due to direct lightning. The fundamental measure of the threat to nuclear safety is assumed to be the maximum voltage between any two points in an assembly area, which is then available for producing arcing or for driving current into critical subsystems of a nuclear weapon. This maximum voltage has been computed with simple analytical models and with three-dimensional finite-difference computer codes.
This paper presents recent progress in using finite-difference analysis codes to simulate the responses of complex structures due to direct lightning. Significant advances have been made in interfacing a finite-difference code with commercial computer aided design tools, in suppressing a pervasive instability associated with the thin-wire algorithm for modeling conductors much smaller than a cell size, and in visualizing the results with color movies. Preliminary comparisons between the results of the finite-difference code and the results obtained during a recent rocket-triggered lightning test are also presented. 3 refs.
Recently, significant progress has been made in using finite-difference analysis cod es to simulate the responses of complex structures due to direct lightning. Advances have been made in interfacing a finite-difference code with commercial computer aided design tools, in suppressing a weak instability associated with the thin-wire algorithm for modeling conductors much smaller than a cell size, and in visualizing the results with color movies. Preliminary comparisons between the results of the finite-difference code and the results obtained during a recent rocket-triggered lightning test are also presented.