Publications

52 Results
Skip to search filters

Next Generation Chemical Agent Detection Architecture [Poster]

Moorman, Matthew W.; Miller, Philip R.; Whiting, Joshua W.; Sammon, Jason P.; Pfeifer, Kent B.; Carlson, Dennis L.; Brusseau, Charles B.

Sandia National Labs (SNL)-designed, portable chemical warfare agent (CWA) detection systems consist of three-stages: collection, separation, and detection. We use microfabrication technologies to miniaturize these stages and to reduce the overall size, weight, power, and (potentially) cost of the final system. Our newest system consists of a multi-dimensional separation stage and an miniature ion mobility spectrometer (IMS) detector for unprecedented system sensitivity, selectivity, and depth of target list.

More Details

μchemLab: Twenty years of developing CBRNE detection systems with low false alarm rates

Proceedings of SPIE - The International Society for Optical Engineering

Whiting, Joshua J.; Myers, Edward B.; Manginell, Ronald P.; Moorman, Matthew W.; Pfeifer, Kent B.; Anderson, John M.; Fix, Cory S.; Washburn, Cody M.; Staton, Alan; Porter, Daniel; Graf, Darin; Wheeler, David R.; Richards, John R.; Achyuthan, Komandoor A.; Roukes, Michael; Simonson, Robert J.

Gas Chromatography (GC) is routinely used in the laboratory to temporally separate chemical mixtures into their constituent components for improved chemical identification. This paper will provide a overview of more than twenty years of development of one-dimensional field-portable micro GC systems, highlighting key experimental results that illustrate how a reduction in false alarm rate (FAR) is achieved in real-world environments. Significantly, we will also present recent results on a micro two-dimensional GC (micro GCxGC) technology. This ultra-small system consists of microfabricated columns, NanoElectroMechanical System (NEMS) cantilever resonators for detection, and a valve-based stop-flow modulator. The separation of a 29-component polar mixture in less than 7 seconds is demonstrated along with peak widths in the second dimension ranging from 10-60 ms. For this system, a peak capacity of just over 300 was calculated for separation in about 6 s. This work has important implications for field detection, to drastically reduce FAR and significantly improve chemical selectivity and identification. This separation performance was demonstrated with the NEMS resonator and bench scale FID. But other detectors, suitably fast and sensitive can work as well. Recent research has shown that the identification power of GCxGC-FID can match that of GC-MS. This result indicates a path to improved size, weight, power, and performance in micro GCxGC systems outfitted with relatively non-specific, lightweight detectors. We will briefly discuss the performance of possible options, such as the pulsed discharge helium ionization detector (PDHID) and miniature correlation ion mobility spectrometer (mini-CIMS).

More Details

Innovative Technologies for Optical Detection of Stress Corrosion Cracks

Bryan, Charles R.; Pfeifer, Kent B.; Buerger, Stephen B.; Schindelholz, Eric J.

Stress corrosion cracks (SCC) represent a major concern for the structural integrity of engineered metal structures. In hazardous or restricted-access environments, remote detection of corrosion or SCC frequently relies on visual methods; however, with standard VT-1 visual inspection techniques, probabilities of SCC detection are low. Here, we develop and evaluate an improved optical sensor for SCC in restricted access-environments by combining a robotically controlled camera/fiber-optic based probe with software-based super-resolution imaging (SRI) techniques to increase image quality and detection of SCC. SRI techniques combine multiple images taken at different viewing angles, locations, or rotations, to produce a single higher- resolution composite image. We have created and tested an imaging system and algorithms for combining optimized, controlled camera movements and super- resolution imaging, improving SCC detection probabilities, and potentially revolutionizing techniques for remote visual inspections of any type.

More Details

Microfabrication of a gadolinium-derived solid-state sensor for thermal neutrons

Journal of Radiation Research

Pfeifer, Kent B.; Achyuthan, Komandoor A.; Allen, Matthew M.; Denton, Michele L.; Siegal, Michael P.; Manginell, Ronald P.

Neutron sensing is critical in civilian and military applications. Conventional neutron sensors are limited by size, weight, cost, portability and helium supply. Here the microfabrication of gadolinium (Gd) conversion material-based heterojunction diodes for detecting thermal neutrons using electrical signals produced by internal conversion electrons (ICEs) is described. Films with negligible stress were produced at the tensile-compressive crossover point, enabling Gd coatings of any desired thickness by controlling the radiofrequency sputtering power and using the zero-point near p(Ar) of 50 mTorr at 100 W. Post-deposition Gd oxidation-induced spallation was eliminated by growing a residual stress-free 50 nm neodymium-doped aluminum cap layer atop Gd. The resultant coatings were stable for at least 6 years, demonstrating excellent stability and product shelf-life. Depositing Gd directly on the diode surface eliminated the air gap, leading to a 200-fold increase in electron capture efficiency and facilitating monolithic microfabrication. The conversion electron spectrum was dominated by ICEs with energies of 72, 132 and 174 keV. Results are reported for neutron reflection and moderation by polyethylene for enhanced sensitivity, and γ- and X-ray elimination for improved specificity. The optimal Gd thickness was 10.4 μm for a 300 μm-thick partially depleted diode of 300 mm 2 active surface area. Fast detection (within 10 min) at a neutron source-to-diode distance of 11.7 cm was achieved with this configuration. All ICE energies along with γ-ray and K α,β X-rays were modeled to emphasize correlations between experiment and theory. Semi-conductor thermal neutron detectors offer advantages for field-sensing of radioactive neutron sources.

More Details

Corrosion Monitors for Embedded Evaluation

Robinson, Alex L.; Pfeifer, Kent B.; Casias, Adrian L.; Howell, Stephen W.; Sorensen, Neil R.; Missert, Nancy A.

We have developed and characterized novel in-situ corrosion sensors to monitor and quantify the corrosive potential and history of localized environments. Embedded corrosion sensors can provide information to aid health assessments of internal electrical components including connectors, microelectronics, wires, and other susceptible parts. When combined with other data (e.g. temperature and humidity), theory, and computational simulation, the reliability of monitored systems can be predicted with higher fidelity.

More Details

Spatial and Temporal Analysis of Bias HAST System Temperature

Pfeifer, Kent B.; Furrer III, Clint T.; Sandoval, Paul A.; Garrett, Stephen E.; Pfeifer, Nathaniel B.

High-reliability components for high-consequence systems require detailed testing of operation after having undergone highly accelerated stress testing (HAST) under unusual conditions of high-temperature and humidity. This paper describes the design and operation of a system called "Wormwood" that is a highly multiplexed temperature measurement system that is designed to operate under HAST conditions to allow measurement of the temperature as a function of time and position in a HAST chamber. HAST chambers have single-point temperature measurements that can be traceable to NIST standards. The objective of these "Wormwood" measurements is to verify the uniformity and stability of the remaining volume of the HAST chamber with respect to the single traceable standard.

More Details

Novel Materials and Devices for Solid-State Neutron Detection

Pfeifer, Kent B.; Achyuthan, Komandoor A.; Allen, Matthew M.; Denton, Michele L.; Siegal, Michael P.; Manginell, Ronald P.

Neutron sensing is critical in civilian, military, industrial, biological, medical, basic research, and environmental applications. Conventional neutron sensors are limited by size, weight, cost, portability, and helium supply. Here the microfabrication of Gd conversion material-based heterojunction diodes is described for detecting thermal neutrons using electrical signals produced by internal conversion electrons (ICE). Films with negligible stress were produced at the tensile-compressive crossover point, enabling Gd coatings of any desired thickness by controlling the radiofrequency sputtering power and using the zero-point near p(Ar) of 50 mTorr at 100 W. Post-deposition Gd oxidation-induced spallation was eliminated by growing a residual stress-free 50 nm neodymium-doped aluminum cap layer atop Gd. Resultant coatings were stable for at least six years demonstrating excellent product shelf life. Depositing Gd on the diode surface eliminated air gap, leading to improved efficiency and facilitating monolithic microfabrication. The conversion electron spectrum was dominated by ICE with energies of 72, 132, and 174 keV. Results are reported on neutron reflection and moderation by polyethylene for enhanced sensitivity and g- and X-ray elimination for improved specificity. Optimal Gd thickness was 10.4 um with 300 um thick partially depleted diode of 300 mm2 active surface area. Fast detection within 10 minutes at a neutron source-to-diode distance of 11.7 cm was achieved using this configuration. All ICE energies along with g-ray and Ka X-ray were modeled to emphasize correlations between experiment and theory and to calculate efficiencies. Semiconductor thermal neutron detectors offer advantages for field-sensing of radioactive neutron sources. ACKNOWLEDGEMENTS Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Company, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000. We thank Edward Cole, David Wheeler, Robert Koudelka, and Lyle Brunke for productive interactions and materials support.

More Details

Carbon Composite Microelectromechanical Systems (CMEMS)

Dyck, Christopher D.; Washburn, Cody M.; Rector, Michael N.; Finnegan, Patrick S.; Pfeifer, Kent B.; Beechem, Thomas E.; Blecke, Jill B.; Satches, Michael R.; Massey, Lee T.; Dyck, Christopher D.

Pyrolyzed carbon as a mechanical material is promising for applications in harsh environments. In this work, we characterized the material and developed novel processes for fabricating carbon composite micro-electromechanical systems (CMEMS) structures. A novel method of increasing Young's modulus and the conductivity of pyrolyzed AZ 4330 was demonstrated by loading the films with graphene oxide prior to pyrolysis. By incorporating 2 wt.% graphene stiffeners into the film, a 65% increase in Young's modulus and 11% increase in conductivity were achieved. By reactive ion etching pyrolyzed blanket AZ 50XT thick film photoresist, a high aspect ratio process was demonstrated with films >7.5um thick. Two novel multi-level, volume-scalable CMEMS processes were developed on 6" diameter wafers. Young's modulus of 23 GPa was extracted from nanoindentation measurements of pyrolyzed AZ 50XT films. The temperature-dependent resistance was characterized from room temperature to 500C and found to be nearly linear over this range. By fitting the results of self-heated bridges in an inert ambient, we calculated that the bridges survived to 1000C without failure. Transmission electron microscopy (TEM) results showed the film to be largely amorphous, containing some sub-micrometer sized graphite crystallites. This was consistent with our Raman analysis, which also showed the film to be largely sp 2 bonded. The calculated average density of pyrolyzed AZ 4330 films was 1.32 g/cm 2 . Thin level of disorder and the conductivity of thin film resistors were found to unchanged by 2Mrad gamma irradiation from a Co 60 source. Thin film pyrolyzed carbon resistors were hermetically sealed in a nitrogen ambient in 24-pin dual in-line packages (DIP's). The resistance was measured periodically and remained constant over 6 months' time.

More Details

Novel Materials and Devices for Solid-State Neutron Detection

Manginell, Ronald P.; Pfeifer, Kent B.

There is a need in many fields, such as nuclear medicine, non-proliferation, energy exploration, national security, homeland security, nuclear energy, etc, for miniature, thermal neutron detectors. Until recently, thermal neutron detection has required physically large devices to provide sufficient neutron interaction and transduction signal. Miniaturization would allow broader use in the fields just mentioned and open up other applications potentially. Recent research shows promise in creating smaller neutron detectors through the combination of high-neutron-cross-section converter materials and solid-state devices. Yet, till recently it is difficult to measure low neutron fluxes by solidstate means given the need for optimized converter materials (purity, chemical composition and thickness) and a lack of designs capable of efficient transduction of the neutron conversion products (x-rays, electrons, gamma rays). Gadolinium-based semiconductor heterojunctions have detected electrons produced by Gd-neutron reactions but only at high neutron fluxes. One of the main limitations to this type of approach is the use of thin converter layers and the inability to utilize all the conversion products. In this LDRD we have optimized the converter material thickness and chemical composition to improve capture of conversion electrons and have detected thermal neutrons with high fidelity at low flux. We are also examining different semiconductor materials and converter materials to attempt to capture a greater percentage of the conversion electrons, both low and higher energy varieties. We have studied detector size and bias scaling, and cross-sensitivity to xrays and shown that we can detect low fluxes of thermal neutrons in less than 30 minutes with high selectivity by our approach. We are currently studying improvements in performance with direct placement of the Gd converter on the detector. The advancement of sensitive, miniature neutron detectors will have benefits in energy production, nonproliferation and medicine.

More Details

Modeling of ESD events from polymeric surfaces

Pfeifer, Kent B.

Transient electrostatic discharge (ESD) events are studied to assemble a predictive model of discharge from polymer surfaces. An analog circuit simulation is produced and its response is compared to various literature sources to explore its capabilities and limitations. Results suggest that polymer ESD events can be predicted to within an order of magnitude. These results compare well to empirical findings from other sources having similar reproducibility.

More Details

Development of MEMS photoacoustic spectroscopy

Eichenfield, Matthew S.; Givler, R.C.; Pfeifer, Kent B.; Reinke, Charles M.; Robinson, Alex L.; Resnick, Paul J.; Griffin, Benjamin G.; Langlois, Eric L.; Nielson, Gregory N.; Okandan, Murat O.

After years in the field, many materials suffer degradation, off-gassing, and chemical changes causing build-up of measurable chemical atmospheres. Stand-alone embedded chemical sensors are typically limited in specificity, require electrical lines, and/or calibration drift makes data reliability questionable. Along with size, these "Achilles' heels" have prevented incorporation of gas sensing into sealed, hazardous locations which would highly benefit from in-situ analysis. We report on development of an all-optical, mid-IR, fiber-optic based MEMS Photoacoustic Spectroscopy solution to address these limitations. Concurrent modeling and computational simulation are used to guide hardware design and implementation.

More Details

Genomics-enabled sensor platform for rapid detection of viruses related to disease outbreak

Brozik, Susan M.; Polsky, Ronen P.; Campbell, DeAnna M.; Manginell, Ronald P.; Moorman, Matthew W.; Edwards, Thayne L.; Anderson, John M.; Pfeifer, Kent B.; Branch, Darren W.

More Details

Surface plasmon sensing of gas phase contaminants using optical fiber

Pfeifer, Kent B.; Thornberg, Steven M.; White, Michael I.

Fiber-optic gas phase surface plasmon resonance (SPR) detection of several contaminant gases of interest to state-of-health monitoring in high-consequence sealed systems has been demonstrated. These contaminant gases include H{sub 2}, H{sub 2}S, and moisture using a single-ended optical fiber mode. Data demonstrate that results can be obtained and sensitivity is adequate in a dosimetric mode that allows periodic monitoring of system atmospheres. Modeling studies were performed to direct the design of the sensor probe for optimized dimensions and to allow simultaneous monitoring of several constituents with a single sensor fiber. Testing of the system demonstrates the ability to detect 70mTorr partial pressures of H{sub 2} using this technique and <280 {micro}Torr partial pressures of H{sub 2}S. In addition, a multiple sensor fiber has been demonstrated that allows a single fiber to measure H{sub 2}, H{sub 2}S, and H{sub 2}O without changing the fiber or the analytical system.

More Details

Mass sensitive, Lorentz-Force actuated, MEMS preconcentrator and chemical sensor

ECS Transactions

Manginell, Ronald P.; Adkins, Douglas R.; Moorman, Matthew W.; Hadizadeh, Rameen; Copic, Davor; Porter, Daniel; Anderson, John M.; Wheeler, David R.; Pfeifer, Kent B.; Rumpf, Arthur

The mass-sensitive smart preconcentrator (SPC) consists of a Lorentz-Force-actuated MEMS resonator with an integral heater and surface coating for the collection of chemical analytes. Control circuitry is used to drive the SPC to resonance and measure its oscillation frequency. The frequency shift produced by adsorption of analyte on the SPC surface is inversely proportional to the mass of analyte collected. Thus, the SPC can measure when it has collected sufficient analyte for a downstream detection system. The limit of detection (LOD) of the SPC is less than 50 ppb for DMMP (dimethyl-methyl- phosphonate). At 1 ppm, less than 1 second collection of DMMP is sufficient to trigger analysis. An analytical model of operation of the SPC is used to predict the motion of the paddle and the shear modulus of silicon. © The Electrochemical Society.

More Details

Developing a laser-based ionization approach for detecting explosives with ion mobility spectrometry

Optics InfoBase Conference Papers

Headrick, Jeffrey M.; Reichardt, Thomas A.; Bambha, Ray B.; Kelley, Jude A.; Pfeifer, Kent B.; Bouchier, Francis A.

Rotationally resolved resonance-enhanced multiphoton ionization (REMPI) spectra of the NO photofragment from nitrobenzene have been observed for the A 2Σ+-X 2Π (1, 0) transition. These spectra were collected in an atmospheric-pressure nitrogen bath. © 2007 Optical Society of America.

More Details

Macro-meso-microsystems integration in LTCC : LDRD report

Rohde, Steven B.; Okandan, Murat O.; Pfeifer, Kent B.; De Smet, Dennis J.; Patel, Kamlesh P.; Ho, Clifford K.; Nordquist, Christopher N.; Walker, Charles A.; Rohrer, Brandon R.; Buerger, Stephen B.; Wroblewski, Brian W.

Low Temperature Cofired Ceramic (LTCC) has proven to be an enabling medium for microsystem technologies, because of its desirable electrical, physical, and chemical properties coupled with its capability for rapid prototyping and scalable manufacturing of components. LTCC is viewed as an extension of hybrid microcircuits, and in that function it enables development, testing, and deployment of silicon microsystems. However, its versatility has allowed it to succeed as a microsystem medium in its own right, with applications in non-microelectronic meso-scale devices and in a range of sensor devices. Applications include silicon microfluidic ''chip-and-wire'' systems and fluid grid array (FGA)/microfluidic multichip modules using embedded channels in LTCC, and cofired electro-mechanical systems with moving parts. Both the microfluidic and mechanical system applications are enabled by sacrificial volume materials (SVM), which serve to create and maintain cavities and separation gaps during the lamination and cofiring process. SVMs consisting of thermally fugitive or partially inert materials are easily incorporated. Recognizing the premium on devices that are cofired rather than assembled, we report on functional-as-released and functional-as-fired moving parts. Additional applications for cofired transparent windows, some as small as an optical fiber, are also described. The applications described help pave the way for widespread application of LTCC to biomedical, control, analysis, characterization, and radio frequency (RF) functions for macro-meso-microsystems.

More Details

Detection of carbon monoxide (CO) as a furnace byproduct using a rotating mask spectrometer

Pfeifer, Kent B.; Sinclair, Michael B.

Sandia National Laboratories, in partnership with the Consumer Product Safety Commission (CPSC), has developed an optical-based sensor for the detection of CO in appliances such as residential furnaces. The device is correlation radiometer based on detection of the difference signal between the transmission spectrum of the sample multiplied by two alternating synthetic spectra (called Eigen spectra). These Eigen spectra are derived from a priori knowledge of the interferents present in the exhaust stream. They may be determined empirically for simple spectra, or using a singular value decomposition algorithm for more complex spectra. Data is presented on the details of the design of the instrument and Eigen spectra along with results from detection of CO in background N{sub 2}, and CO in N{sub 2} with large quantities of interferent CO{sub 2}. Results indicate that using the Eigen spectra technique, CO can be measured at levels well below acceptable limits in the presence of strongly interfering species. In addition, a conceptual design is presented for reducing the complexity and cost of the instrument to a level compatible with consumer products.

More Details

Advanced polychromator systems for remote chemical sensing (LDRD project 52575)

Allen, James J.; Sinclair, Michael B.; Pfeifer, Kent B.

The objective of this LDRD project was to develop a programmable diffraction grating fabricated in SUMMiT V{trademark}. Two types of grating elements (vertical and rotational) were designed and demonstrated. The vertical grating element utilized compound leveraged bending and the rotational grating element used vertical comb drive actuation. This work resulted in two technical advances and one patent application. Also a new optical configuration of the Polychromator was demonstrated. The new optical configuration improved the optical efficiency of the system without degrading any other aspect of the system. The new configuration also relaxes some constraint on the programmable diffraction grating.

More Details

Nano electrode arrays for in-situ identification and quantification of chemicals in water

Yelton, William G.; Pfeifer, Kent B.

The nano electrode arrays for in-situ identification and quantification of chemicals in water progress in four major directions. (1) We developed and engineering three nanoelectrode array designs which operate in a portable field mode or as distributed sensor network for water systems. (2) To replace the fragile glass electrochemical cells using in the lab, we design and engineered field-ready sampling heads that combine the nanoelectrode arrays with a high-speed potentiostat. (3) To utilize these arrays in a portable system we design and engineered a light weight high-speed potentiostat with pulse widths from 2 psec. to 100 msec. or greater. (4) Finally, we developed the parameters for an analytical method in low-conductivity solutions for Pb(II) detection, with initial studies for the analysis of As(III) and As(V) analysis in natural water sources.

More Details

Embedded Self-Powered MicroSensors for Monitoring the Surety of Critical Buildings and Infrastructures

Pfeifer, Kent B.; Rumpf, Arthur N.; Leming, Sarah L.

Monitoring the condition of critical structures is vital for not only assuring occupant safety and security during naturally occurring and malevolent events, but also to determine the fatigue rate under normal aging conditions and to allow for efficient upgrades. This project evaluated the feasibility of applying integrated, remotely monitored micro-sensor systems to assess the structural performance of critical infrastructure. These measurement systems will provide forensic data on structural integrity, health, response, and overall structural performance in load environments such as aging, earthquake, severe wind, and blast attacks. We have investigated the development of ''self-powered'' sensor tags that can be used to monitor the state-of-health of a structure and can be embedded in that structure without compromising the integrity of the structure. A sensor system that is powered by converting structural stresses into electrical power via piezoelectric transducers has been demonstrated including work toward integration of that sensor with a novel radio frequency (RF) tagging technology as a means of remotely reading the data from the sensor.

More Details

An Examination of System Architectures for Distributing Sensor Data Via Ethernet Networks

Pfeifer, Kent B.; Cernosek, R.W.

Application of the World Wide Web (WWW) for the transfer of sensor data from remote locations to laboratories and offices is a largely ignored application of the WWW. We have investigated several architectures for this application including simple web server/client architectures and variations of this approach. In addition, we have evaluated several commercial approaches and other techniques that have been investigated and are in the literature. Finally, we have provided conclusions based on the results of our study offering suggestions about the advantages and disadvantages of each of the approaches studied.

More Details

Characteristics and Mechanisms in Ion-Conducting Polymer Films as Chemical Sensors

The Electrochemical Society

Yelton, William G.; Pfeifer, Kent B.

Solid Polymer Electrolytes (SPE) are widely used in batteries and fuel cells because of the high ionic conductivity that can be achieved at room temperature. The ions are usually Li or protons, although other ions can be shown to conduct in these polymer films. There has been very little published work on SPE films used as chemical sensors. The authors have found that thin films of polymers like polyethylene oxide (PEO) are very sensitive to low concentrations of volatile organic compounds (VOCs) such as common solvents. Evidence of a new sensing mechanism involving the percolation of ions through narrow channels of amorphous polymer is presented. They present impedance spectroscopy of PEO films in the frequency range 0.0001 Hz to 1 MHz for different concentrations of VOCs and relative humidity. They find that the measurement frequency is important for distinguishing ionic conductivity from the double layer capacitance and the parasitic capacitance.

More Details
52 Results
52 Results