Publications

13 Results
Skip to search filters

The ultrafast pixel array camera system and its applications in high energy density physics

Review of Scientific Instruments

Looker, Quinn M.; Oberla, Eric O.; Stahoviak, John W.; Mostafanezhad, Isar M.; Pang, Ryan P.; Luck, Marcus L.; Galloway, Ben G.; Rambo, Patrick K.; Porter, John L.

Diagnostics in high energy density physics, shock physics, and related fields are primarily driven by a need to record rapidly time-evolving signals in single-shot events. These measurements are often limited by channel count and signal degradation issues on cable links between the detector and digitizer. Here we present the Ultrafast Pixel Array Camera (UPAC), a compact and flexible detector readout system with 32 waveform-recording channels at up to 10 Gsample/s and 1.8 GHz analog bandwidth. The compact footprint allows the UPAC to be directly embedded in the detector environment. A key enabling technology is the PSEC4A chip, an eight-channel switch-capacitor array sampling device with up to 1056 samples/channel. The UPAC system includes a high-density input connector that can plug directly into an application-specific detector board, programmable control, and serial readout, with less than 5 W of power consumption in full operation. We present the UPAC design and characterization, including a measured timing resolution of ~20 ps or better on acquisitions of sub-nanosecond pulses with minimal system calibrations. Example applications of the UPAC are also shown to demonstrate operation of a solid-state streak camera, an ultrafast imaging array, and a neutron time-of-flight spectrometer.

More Details

Phase modulation failsafe system for multi-kJ lasers based on optical heterodyne detection

Review of Scientific Instruments

Armstrong, Darrell J.; Looker, Quinn M.; Stahoviak, John W.; Smith, Ian C.; Shores, J.E.; Rambo, Patrick K.; Schwarz, Jens S.; Speas, C.S.; Porter, John L.

Amplification of the transverse scattered component of stimulated Brillouin scattering (SBS) can contribute to optical damage in the large aperture optics of multi-kJ lasers. Because increased laser bandwidth from optical phase modulation (PM) can suppress SBS, high energy laser amplifiers are injected with PM light. Phase modulation distributes the single-frequency spectrum of a master oscillator laser among individual PM sidebands, so a sufficiently high modulation index β can maintain the fluence for all spectral components below the SBS threshold. To avoid injection of single frequency light in the event of a PM failure, a high-speed PM failsafe system (PMFS) must be employed. Because PM is easily converted to AM, essentially all PM failsafes detect AM, with the one described here employing a novel configuration where optical heterodyne detection converts PM to AM, followed by passive AM power detection. Although the PMFS is currently configured for continuous monitoring, it can also detect PM for pulse durations ≥2 ns and could be modified to accommodate shorter pulses. This PMFS was deployed on the Z-Beamlet Laser (ZBL) at Sandia National Laboratories, as required by an energy upgrade to support programs at Sandia's Z Facility such as magnetized liner inertial fusion. Depending on the origin of a PM failure, the PMFS responds in as little as 7 ns. In the event of an instantaneous failure during initiation of a laser shot, this response time translates to a 30-50 ns margin of safety by blocking a pulse from leaving ZBL's regenerative amplifier, which prevents injection of single frequency light into the main amplification chain. The performance of the PMFS, without the need for operator interaction, conforms to the principles of engineered safety.

More Details

A Window-less Target for Magnetized Liner Inertial Fusion Characterized using High-Speed Solid-State Framing Cameras

Colombo, Anthony P.; Schwarz, Jens S.; Rambo, Patrick K.; Galloway, B.R.; Kimmel, Mark W.; Slutz, Stephen A.; Weis, Matthew R.; Claus, Liam D.; England, Troy D.; Fang, Lu F.; Looker, Quinn M.; Mitchell, Brandon M.; Montoya, Andrew M.; Robertson, Gideon R.; Rochau, G.A.; Sanchez, Marcos O.; Stahoviak, John W.; Hund, Jared H.; Sin, Justin S.; Porter, John L.

Abstract not provided.

Initial characterization results of a 1024x448, 25-μm multi-frame camera with 2ns integration time for the Ultrafast X-ray Imager (UXI) program at Sandia National Laboratories

Proceedings of SPIE - The International Society for Optical Engineering

Claus, Liam D.; Robertson, Gideon R.; Fang, L.; Kay, R.; Kimmel, M.W.; Sanchez, Marcos O.; Stahoviak, John W.; Trotter, D.; Porter, John L.

The Hippogriff camera developed at Sandia National Laboratories as part of the Ultra-Fast X-ray Imager (UXI) program is a high-speed, multi-frame, time-gated imager for use on a wide variety of High Energy Density (HED) physics experiments on both Sandia's Z-Machine and the National Ignition Facility. The camera is a 1024 x 448 pixel array with 25 μm spatial resolution, containing 2 frames per pixel natively and has achieved 2 ns minimum integration time. It is sensitive to both optical photons as well as soft X-rays up to ∼6 keV. The Hippogriff camera is the second generation UXI camera that contains circuitry to trade spatial resolution for additional frames of temporal coverage. The user can reduce the row-wise spatial resolution from the native 25 μm to increase the number of frames in a data set to 4 frames at 50 μm or 8 frames at 100 μm spatial resolution. This feature, along with both optical and X-ray sensitivity, facilitates additional experimental flexibility. Minimum signal is 1500 erms and full well is 1.5 million e-.

More Details

An overview of the ultra-fast X-ray imager (UXI) program at Sandia Labs

Proceedings of SPIE - The International Society for Optical Engineering

Claus, Liam D.; Fang, Lu F.; Kay, R.; Kimmel, Mark W.; Long, J.; Robertson, Gideon R.; Sanchez, Marcos O.; Stahoviak, John W.; Trotter, D.; Porter, John L.

The Ultra-Fast X-ray Imager (UXI) program is an ongoing effort at Sandia National Laboratories to create high speed, multi-frame, time gated Read Out Integrated Circuits (ROICs), and a corresponding suite of photodetectors to image a wide variety of High Energy Density (HED) physics experiments on both Sandia's Z-Machine and the National Ignition Facility (NIF). The program is currently fielding a 1024 x 448 prototype camera with 25 μm pixel spatial resolution, 2 frames of in-pixel storage and the possibility of exchanging spatial resolution to achieve 4 or 8 frames of storage. The camera's minimum integration time is 2 ns. Minimum signal target is 1500 e-rms and full well is 1.5 million e-. The design and initial characterization results will be presented as well as a description of future imagers.

More Details

Adaptive Beam Smoothing with Plasma-Pinholes for Laser-Entrance-Hole Transmission Studies

Geissel, Matthias G.; Awe, Thomas J.; Campbell, Edward M.; Gomez, Matthew R.; Harding, Eric H.; Harvey-Thompson, Adam J.; Jennings, Christopher A.; Kimmel, Mark W.; Lewis, Sean M.; McBride, Ryan D.; Peterson, Kyle J.; Schollmeier, Marius; Sefkow, Adam B.; Shores, Jonathon S.; Sinars, Daniel S.; Slutz, Stephen A.; Smith, Ian C.; Speas, Christopher S.; Stahoviak, John W.; Porter, John L.

Abstract not provided.

13 Results