Publications

66 Results
Skip to search filters

The role of ions during stable impedance operation of the immersed- B z diode at 4 to 5 MV

Physics of Plasmas

Rovang, Dean C.; Bruner, N.; Maenchen, John E.; Oliver, Bryan V.; Portillo, Salvador; Puetz, E.; Rose, D.V.; Welch, D.R.

The immersed- Bz diode is being developed as a high-brightness, flash x-ray radiography source at Sandia National Laboratories. This diode is a foil-less electron-beam diode with a long, thin, needlelike cathode that is inserted into the bore of a solenoid. The solenoidal magnetic field guides the electron beam emitted from the cathode to the anode while maintaining a small beam radius. The electron beam strikes a thin, high-atomic-number anode and produces forward-directed bremsstrahlung. In addition, electron beam heating of the anode produces surface plasmas allowing ion emission. Two different operating regimes for this diode have been identified: a nominal operating regime where the total diode current is characterized as classically bipolar and an anomalous operating regime characterized by a dramatic impedance collapse where the total diode current greatly exceeds the bipolar limit. Data from a comprehensive series of experiments fielded at 4 and 5 MV, where the diode operates in the nominal or stable impedance regime, with beam currents ranging from 20-40 kA on target are presented. In this mode, both the measured diode current and experimental radiation production are consistent with physics based models including two-dimensional particle-in-cell simulations. The analysis indicates that intermediate mass ions (e.g., 12-18 amu) control the nominal impedance evolution rather than expected lighter mass ions such as hydrogen. © 2007 American Institute of Physics.

More Details

A 5-megavolt, 600-kiloampere laser-triggered gas switch for use on Z-R: Comparison of experiments and simulations

Digest of Technical Papers-IEEE International Pulsed Power Conference

Woodworth, Joseph R.; Rosenthal, Stephen E.; Lehr, J.M.; Maenchen, John E.; Elizondo, J.; Johnson, D.L.; Corley, J.P.; Hodge, K.C.; Drennan, S.A.; Guthrie, D.W.

The Z Refurbishment project is designed to increase the peak current to the load on Z to ∼26 MA in a 100-ns wide power pulse. This current is achieved by summing the current from 36 independent pulse-power modules. To meet these requirements, we have designed and constructed an SF6-insulated gas switch that can hold off 5.5 MV and conduct a peak current of 600 kA for over a hundred shots. The gas switch is charged by a Marx generator in ∼1 microsecond and transfers about 200-kilojoules of energy and 0.25 Coulombs of charge to a pulse-forming line in a ∼150-ns-wide power pulse peaking at 2.5 TW. The gas switch oonsists of a laser-triggered section holding off 15% of the voltage followed by 25 self-breakdown gaps. The self-breaking gaps are designed to provide multiple breakdown arcs in order to lower the overall inductance of the switch. The gas switch is submerged in transformer oil during operation. In this work, we show how simulation and experiment have worked together, first to verify proper operation of the switch, and then to solve problems with the switch design that arose during testing. © 2005 IEEE.

More Details

Performance of self-closing diverter switches for ZR/Z20 marx and intermediate store protection

Digest of Technical Papers-IEEE International Pulsed Power Conference

Douglas, J.; Banister, J.; Corcoran, P.; Goyer, J.; Miller, R.; Morton, D.; Nishimoto, H.; Smith, I.; Corley, J.; Drennan, S.; Guthrie, D.; Hodge, K.; Lehr, J.M.; Maenchen, John E.; Smith, D.; Sears, R.

The ZR refurbishment project [1] at Sandia National Laboratories (SNL) required a set of diverter switches to protect the Marx generators and intermediate storage (IS) capacitors from Marx pre-fire and/or laser triggered output switch (LTS) no-fire. Thirty-six such diverters, one for each Marx-IS set, will need to operate reliably over the full range of Marx charge voltages and LTS anticipated closure times. Operating voltage is up to 6 MV. A self-closing oil switch diverter was selected and design work began in late 2002. The first diverter (Phase I or just P1) was delivered in the summer of 2003 and tested on SNL's Z20 test-bed. Based on test results, operational experience and overall project budgetary concerns, it was decided to re-design the diverter, resulting a simpler, less costly switch. This new self-closing oil switch (Phase II or P2) was fielded at SNL on the Z20 test-bed in late 2004. Both designs include adjustable electrodes to control the closure time. Also incorporated is a mechanical clamp that minimizes or shorts the oil gap until Marx charge is complete. Both diverters feature liquid resistors sized to safely absorb the energy stored in the Marx or IS. This paper describes the design and test results from these diverters. © 2005 IEEE.

More Details

Development and testing of immersed-Bz diodes with cryogenic anodes

Digest of Technical Papers-IEEE International Pulsed Power Conference

Rovang, Dean C.; Van De Valde, D.; Gregerson, D.; Puetz, E.; Bruner, N.; Cooper, G.; Cordova, S.; Droemer, D.; Hahn, K.; Johnston, Mark D.; Maenchen, John E.; McLean, J.; Molina, I.; Oliver, B.; O'Malley, J.; Portillo, Salvador; Welch, D.

Sandia National Laboratories is investigating and developing high-dose, high-brightness flash radiographic sources. The immersed-Bz diode employs large-bore, high-field solenoid magnets to help guide and confine an intense electron beam from a needle-like cathode "immersed" in the axial field of the magnet. The electron beam is focused onto a high-atomic-number target/anode to generate an intense source of bremsstrahlung X-rays. Historically, these diodes have been unable to achieve high dose (> 500 rad @ m) from a small spot (< 3 mm diameter). It is believed that this limitation is due in part to undesirable effects associated with the interaction of the electron beam with plasmas formed at either the anode or the cathode. Previous research concentrated on characterizing the behavior of diodes, which used untreated, room temperature (RT) anodes. Research is now focused on improving the diode performance by modifying the diode behavior by using cryogenic anodes that are coated in-situ with frozen gases. The objective of these cryogenically treated anodes is to control and limit the ion species of the anode plasma formed and hence the species of the counter-streaming ions that can interact with the electron beam. Recent progress in the development, testing and fielding of the cryogenically cooled immersed diodes at Sandia is described. ©2005 IEEE.

More Details

Status of the 10 MV, 120 kA RITS-6 inductive voltage adder

Digest of Technical Papers-IEEE International Pulsed Power Conference

Johnson, D.; Bailey, V.; Altes, R.; Corcoran, P.; Smith, I.; Cordova, S.; Hahn, K.; Maenchen, John E.; Molina, I.; Portillo, Salvador; Puetz, E.; Sceiford, Matthew S.; Van De Valde, D.; Rose, D.; Oliver, B.; Welch, D.; Droemer, D.

The six-cell RITS-6 accelerator is an upgrade of the existing RITS-3 accelerator and is next in the sequence of Sandia IVA accelerators built to investigate/validate critical accelerator and radiographic diode issues for scaling to the Radiographic Integrated Test Stand (RITS) (nominally 16 MV, 156 kA, and 70 ns). In the RITS-6 upgrade to RITS-3 the number of cells/cavities, PFLs, laser triggered gas switches and intermediate stores is being doubled. A rebuilt single 61-nF Marx generator will charge the two intermediate storage capacitors. The RITS-3 experiments have demonstrated a MITL configuration matched to the PFL/induction cell impedance and a higher impedance MITL. RITS-6 is designed to utilize the higher impedance MITL providing a 10.5-MV, 123-kA output. The three years of pulsed power performance data from RITS-3 will be summarized and the design improvements being incorporated into RITS-6 will be outlined. The predicted output voltage and current for RITS-6 as a function of diode impedance will be shown. Particle-in-cell simulations of the vacuum power flow from the cell to the load for a range of diode impedances from matched to ∼40 Ohms will be shown and compared with the re-trapped parapotential flow predictions. The status of the component fabrication and system integration will be given. Another potential upgrade under consideration is RITS-62. In this case the RITS-6 Marx, intermediate stores, gas switches, and PFLs would be duplicated and a tee would replace the elbow that now connects a single PFL to a cell thereby allowing two PFLs to be connected to one cell. The output of RITS-62 matched to the cell/PFL impedance would then be 8 MV, 312 kA or 25.6 ohms. The predicted operating curves for RITS-62 with other non-matched MITLs will be shown. The power delivered to a radiographic diode can be maximized by the correct choice of MITL impedance given the cell/PFL and radiographic diode impedances. If the radiated output for a given diode has a stronger than linear voltage dependence this dependence can also be included in the correct choice of MITL impedance. The optimizations and trade-offs will be shown for RITS-6 and RITS-62 for diode impedances characteristic of radiographic diodes. © 2005 IEEE.

More Details

Copy of An overview of pulse compression and power flow in the upgraded Z pulsed power driver

Savage, Mark E.; Maenchen, John E.; McDaniel, Dillon H.; Pasik, Michael F.; Pointon, Timothy D.; Owen, Albert C.; Seidel, David B.; Stoltzfus, Brian S.; Struve, Kenneth W.; Warne, Larry K.; Bennett, Lawrence F.; Woodworth, Joseph R.; Bliss, David E.; Clark, Waylon T.; Coats, Rebecca S.; Elizondo-Decanini, Juan M.; LeChien, Keith R.; Harjes, Henry C.; Lehr, J.M.

Abstract not provided.

Fundamental science investigations to develop a 6-MV laser triggered gas switch for ZR: first annual report

Maenchen, John E.; Savage, Mark E.; Struve, Kenneth W.; Woodworth, Joseph R.; Lehr, J.M.; Warne, Larry K.; Bliss, David E.; Jorgenson, Roy E.; LeChien, Keith R.; McKee, George R.; Pasik, Michael F.; Rosenthal, Stephen E.

In October 2005, an intensive three-year Laser Triggered Gas Switch (LTGS) development program was initiated to investigate and solve observed performance and reliability issues with the LTGS for ZR. The approach taken has been one of mission-focused research: to revisit and reassess the design, to establish a fundamental understanding of LTGS operation and failure modes, and to test evolving operational hypotheses. This effort is aimed toward deploying an initial switch for ZR in 2007, on supporting rolling upgrades to ZR as the technology can be developed, and to prepare with scientific understanding for the even higher voltage switches anticipated needed for future high-yield accelerators. The ZR LTGS was identified as a potential area of concern quite early, but since initial assessments performed on a simplified Switch Test Bed (STB) at 5 MV showed 300-shot lifetimes on multiple switch builds, this component was judged acceptable. When the Z{sub 20} engineering module was brought online in October 2003 frequent flashovers of the plastic switch envelope were observed at the increased stresses required to compensate for the programmatically increased ZR load inductance. As of October 2006, there have been 1423 Z{sub 20} shots assessing a variety of LTGS designs. Numerous incremental and fundamental switch design modifications have been investigated. As we continue to investigate the LTGS, the basic science of plastic surface tracking, laser triggering, cascade breakdown, and optics degradation remain high-priority mission-focused research topics. Significant progress has been made and, while the switch does not yet achieve design requirements, we are on the path to develop successively better switches for rolling upgrade improvements to ZR. This report summarizes the work performed in FY 2006 by the large team. A high-level summary is followed by detailed individual topical reports.

More Details

Operational characteristics and analysis of the immersed-Bz diode on RITS-3

Rovang, Dean C.; Johnston, Mark D.; Maenchen, John E.; Oliver, Bryan V.; Portillo, Salvador; Madrid, Elizabeth A.

The immersed-B{sub z} diode is being developed as a high-brightness, flash x-ray radiography source. This diode is a foil-less electron-beam diode with a long, thin, needle-like cathode inserted into the bore of a solenoid. The solenoidal magnetic field guides the electron beam emitted from the cathode to the anode while maintaining a small beam radius. The electron beam strikes a thin, high-atomic-number anode and produces bremsstrahlung. We report on an extensive series of experiments where an immersed-B{sub z} diode was fielded on the RITS-3 pulsed power accelerator, a 3-cell inductive voltage generator that produced peak voltages between 4 and 5 MV, {approx}140 kA of total current, and power pulse widths of {approx}50 ns. The diode is a high impedance device that, for these parameters, nominally conducts {approx}30 kA of electron beam current. Diode operating characteristics are presented and two broadly characterized operating regimes are identified: a nominal operating regime where the total diode current is characterized as classically bipolar and an anomalous impedance collapse regime where the total diode current is in excess of the bipolar limit and up to the full accelerator current. The operating regimes are approximately separated by cathode diameters greater than {approx}3 mm for the nominal regime and less than {approx} 3 mm for the anomalous impedance collapse regime. This report represents a compilation of data taken on RITS-3. Results from key parameter variations are presented in the main body of the report and include cathode diameter, anode-cathode gap, and anode material. Results from supporting parameter variations are presented in the appendices and include magnetic field strength, prepulse, pressure and accelerator variations.

More Details

Circuit Simulations of a 1 MV LTD for radiography

Leckbee, Joshua L.; Maenchen, John E.; Portillo, Salvador; Molina, I.

A 1 MV linear transformer driver (LTD), capable of driving a radiographic diode load, has been built and tested. A circuit model of this accelerator has been developed using the BERTHA circuit simulation code. Simulations are compared to data from power-flow experiments utilizing a large area electron-beam diode load. Results show that the simulation model performs well in modeling the baseline operation of the accelerator. In addition, the circuit model has been used to predict several possible fault modes. Simulations of switch prefires, main capacitor failure, vacuum insulator flashover, and core saturation have been used to estimate the probability of inducing further failures and the impact on the load voltage and current.

More Details

Reliability assessment of a 1 MV LTD

Leckbee, Joshua L.; Maenchen, John E.; Portillo, Salvador; Molina, I.

A 1 MV linear transformer driver (LTD) is being tested with a large area e-beam diode load at Sandia National Laboratories (SNL). The experiments will be utilized to determine the repeatability of the output pulse and the reliability of the components. The 1 MV accelerator is being used to determine the feasibility of designing a 6 MV LTD for radiography experiments. The peak voltage, risetime, and pulse width as well as the cavity timing jitter are analyzed to determine the repeatability of the output pulse.

More Details

Plasma spectroscopy diagnostics in pulsed-power X-ray radiography diode research

Johnston, Mark D.; Hahn, Kelly D.; Rovang, Dean C.; Portillo, Salvador; Maenchen, John E.

Spectroscopic investigations in the visible and near UV are underway to study plasmas present in X-ray radiography diodes during the time of the electron beam propagation. These studies are being performed on the RITS-3 accelerator (5.25 MV and 120 kA) at Sandia National Laboratories using several diode configurations. The proper characterization of the plasmas occurring during the time of the X-ray pulse can lead to a greater understanding of diode behavior and X-ray spot size evolution. By studying these plasmas along with the use of selective dopants, insights into such phenomena as impedance collapse, thermal and non-thermal species behavior, charge and current neutralization, anode and cathode plasma formation and propagation, and beam/foil interactions, can be obtained. Information from line and continuum emission and absorption can give key plasma parameters such as temperatures, densities, charge states, and expansion velocities. This information is important for proper modeling and future predictive capabilities for the design and improvement of flash X-ray radiography diodes. Diagnostics include a gated, intensified multichannel plate camera combined with a 1 meter Czerny-Turner monochromator with a multi-fiber spectral input, allowing for both temporal and spatial resolution. Recent results are presented.

More Details

Radiation predictions and shielding calculations for RITS-6

Maenchen, John E.; Kensek, Ronald P.; Fan, Wesley C.

The mission of Radiographic Integrated Test Stand-6 (RITS-6) facility is to provide the underlying science and technology for pulsed-power-driven flash radiographic X-ray sources for the National Nuclear Security Administration (NNSA). Flash X-ray radiography is a penetrating diagnostic to discern the internal structure in dynamic experiments. Short (~50 nanosecond (ns) duration) bursts of very high intensity Xrays from mm-scale source sizes are required at a variety of voltages to address this mission. RITS-6 was designed and is used to both develop the accelerator technology needed for these experiments and serves as the principal test stand to develop the high intensity electron beam diodes that generate the required X-ray sources. RITS is currently in operation with three induction cavities (RITS-3) with a maximum voltage output of 5.5 MV and is classified as a low hazard non-nuclear facility in accordance with CPR 400.1.1, Chapter 13, Hazards Identification/Analysis and Risk Management. The facility will be expanded from three to six cavities (RITS-6) effectively doubling the operating voltage. The increase in the operating voltage to above 10 MV has resulted in RITS-6 being classified as an accelerator facility. RITS-6 will come under DOE Order 420.2B, Safety of Accelerator Facilities. The hazards of RITS are detailed in the "Safety Assessment Document for the Radiographic Integrated Test Stand Facility." The principal non-industrial hazard is prompt x-ray radiation. As the operating voltage is increased, both the penetration power and the total amount (dose) of x-rays are increased, thereby increasing the risk to local personnel. Fixed site shielding (predominantly concrete walls and a steel/lead skyshine shield) is used to attenuate these x-rays and mitigate this risk. This SAND Report details the anticipated x-ray doses, the shielding design, and the anticipated x-ray doses external to this shielding structure both in areas where administrative access control restricts occupation and in adjacent uncontrolled areas.

More Details

Plasma-filled focusing cell for radiographic paraxial diodes on RITS

Conference Record of the International Power Modulator Symposium and High Voltage Workshop

Hahn, K.; Maenchen, John E.; Cordova, S.; Molina, I.; Portillo, Salvador; Rovang, Dean C.; Schamiloglu, E.; Welch, D.R.; Oliver, B.V.; Rose, D.V.

Paraxial diodes have been a stronghold for high-brightness, flash x-ray radiography. In its traditional configuration, an electron beam impinges onto an anode foil, entering a gas-filled transport cell. Within the cell, the beam is focused into a small spot onto a high-Z target to generate x-rays for the radiographic utility. Simulations using Lsp, a particle-in-cell code, have shown that within the gas-filled focusing cell the electron beam spot location sweeps axially during the course of the beam pulse. The result is a larger radiographic spot than is desirable. Lsp has also shown that replacing the gas-filled cell with a fully ionized plasma on the order of 1016 cm-3 will prevent the spot from significant beam sweeping, thus resulting in a smaller, more stable radiographic spot size. Sandia National Laboratories (SNL) is developing a plasma-filled focusing cell for future paraxial diode experiments. A z-discharge in a hydrogen fill is used to generate a uniform, highly ionized plasma. Laser interferometry is the key diagnostic to determine electron density in a light lab setting and during future paraxial diode shots on SNL's RITS-3 accelerator. A time-resolved spot diagnostic will also be implemented during diode shots to measure the change in spot size during the course of the pulse. © 2004 IEEE.

More Details

Advances in pulsed-power-driven radiography system design

Maenchen, John E.; Cordova, S.; Bohlken, Fawn A.; Hahn, Kelly D.; Jaramillo, Deanna M.; Molina, I.; Portillo, Salvador; Madrid, Elizabeth A.; Rovang, Dean C.; Sceiford, Matthew S.

Flash x-ray radiography has undergone a transformation in recent years with the resurgence of interest in compact, high intensity pulsed-power-driven electron beam sources. The radiographic requirements and the choice of a consistent x-ray source determine the accelerator parameters, which can be met by demonstrated Induction Voltage Adder technologies. This paper reviews the state of the art and the recent advances which have improved performance by over an order of magnitude in beam brightness and radiographic utility.

More Details

RITS-3 self-break water switch maintenance

Portillo, Salvador; Hahn, Kelly D.; Molina, I.; Cordova, S.; Maenchen, John E.

The radiographic integrated test stand (RITS-3) is a 5-MV, 160-kA, 70-ns inductive voltage adder accelerator at Sandia National Laboratories used to develop critical understanding of x-ray sources and flash radiographic drivers. On RITS-3 three pulse forming lines (PFLs) are used to drive three inductive voltage adder cavities. Each PFL contains a fast-pulse-charged, self-breakdown annular water switch that is used for initial pulse shaping and timing. Low loss in the switches combined with good synchronization is required for efficient operation of the accelerator. Switch maintenance is closely monitored over time to determine the effects of wear on switch breakdown performance.

More Details

Transport of a relativistic electron beam in gas and plasma-filled focusing cells for x-ray radiography

Physics of Plasmas

Welch, Dale R.; Rose, D.V.; Oliver, Bryan V.; Schamiloglu, E.; Hahn, K.; Maenchen, John E.

The propagation of a 30 kA, 3.5 Mev electron beam which was focused into gas and plasma-filled cells was discussed. Gas cells which were used for X-ray radiography were produced using pulsed-power accelerators, onto a high atomic number target to generate bremsstrahlung radiation. The effectiveness of beam focusing using neutral gas, partially ionized gas, and fully ionized (plasma-filled) cells was investigated using numerical simulation. It was observed in an optimized gas cell that an initial plasma density approaching 1016 cm-3 was sufficient to prevent significant net currents and the subsequent beam sweep.

More Details

ZR Marx capacitor vendor evaluation results and procurement strategy

Digest of Technical Papers-IEEE International Pulsed Power Conference

Smith, David L.; Savage, Mark E.; Maenchen, John E.; McDaniel, Dillon H.; Slattery, Michael J.; Weinbrecht, Edward A.; Kitterman, David L.; Starbird, Robert L.

To meet or exceed the 26-MA goal for ZR, the refurbished upgrade to the Z machine at Sandia National Labs, the existing Marx generator capacitors must be replaced with identical size units but with twice the capacitance. Before the six-month shut down and transition from Z to ZR occurs in late 2005, most of the 2500 capacitors must be delivered for acceptance testing and installation. We chose to undertake an ambitious vendor qualification program to reduce the risk of not meeting ZR performance goals, to encourage the pulsed-power industry to revisit the design and development of high energy discharge capacitors, and to meet the cost and delivery schedule within the ZR project plans. Five manufacturers were willing to fabricate and sell Sandia samples of six capacitors each to be evaluated. In addition, four more samples of modified or alternate designs were submitted for testing at the vendors' expense, giving us a total of 45 capacitors to test. The 8,000-shot qualification test phase of the effort is now complete. This paper summarizes how the 0.279×0.356×0.635-m Scyllac-style 2.6-μF, <30-nH, 100-kV, 35%-reversal capacitor lifetime specifications were determined, briefly describes the nominal 260-kJ test facility configuration, presents the test results of the most successful candidates, and provides procurement strategy and acceptance testing protocols that balance available resources against performance, cost, and schedule risk.

More Details

Development of a dynamic spot size diagnostic for flash radiographic x-ray sources

Digest of Technical Papers-IEEE International Pulsed Power Conference

Lutz, Stephen; Droemer, Darryl; Devore, Douglas; Rovang, Dean C.; Portillo, Salvador; Maenchen, John E.

There has been considerable work in recent years in the development of high-brightness, high-dose flash x-ray radiographic sources. Spot size is one of several parameters that helps characterize source performance and provides a figure of merit to assess the suitability of various sources to specific experimental requirements. Time-integrated spot-size measurements using radiographic film and a high-Z rolled-edge object have been used for several years with great success. The Advanced Radiographic Technologies program thrust to improve diode performance requires extending both modeling and experimental measurements into the transient time domain. A new Time Resolved Spot Detector (TRSD) is under development to provide this information. In this paper we report the initial results of the performance of a 148-element scintillating fiber array that is fiber-optically coupled to a gated streak camera. Spatial and temporal resolution results are discussed and the data obtained from the Sandia National Laboratories (SNL) RITS-3 (Radiographic Integrated Test Stand) accelerator are presented.

More Details

Initial experimental results of re-trapping studies on a large area diode on RITS-3

Digest of Technical Papers-IEEE International Pulsed Power Conference

Portillo, Salvador; Hahn, K.; Maenchen, John E.; Molina, I.; Cordova, S.; Johnson, David L.; Rose, D.; Oliver, Bryan V.; Welch, D.

As part of a continuous research effort into advanced flash radiographic sources using intense electron beams, Sandia National Laboratories (SNL) has been investigating coupling vacuum power flow into various high power diodes. Of key importance is the issue of the re-trapping of electrons from the sheath current of a magnetically insulated vacuum transmission line (MITL) into the diode load. Results of electron re-trapping studies on a large area diode (LAD) on the RITS-3 accelerator are presented here. RITS-3 is a 4.5 MV, 160 kA inductive voltage adder pulsed power accelerator. Results show that re-trapping of the sheath current does occur and compares favorably with particle in cell (PIC) predictions of the LSP modeling code.

More Details

Survey of plasma diagnostic techniques applicable to radiographic diodes

Digest of Technical Papers-IEEE International Pulsed Power Conference

Schamiloglu, E.; Hahn, K.; Rovang, Dean C.; Maenchen, John E.; Cordova, S.; Molina, I.; Welch, Dale R.; Rose, D.V.; Oliver, Bryan V.; Weber, B.V.; Ponce, D.; Hinshelwood, D.D.

Plasmas are ubiquitous in the high-power electron beam diodes used for radiographic applications. In rod pinch and immersed Bz diodes they are found adjacent to the cathode and anode electrodes, and are suspected of affecting the diodes' impedance characteristics as well as the radiographic spot size. In paraxial diodes, preionized plasmas or beam-formed plasmas are also found in the gas focusing section. A common feature of the plasmas adjacent to the electrodes is that their densities can range from 10 12-1017 cm-3, and their velocity is on the order of 107 cm/s. Researchers from the Naval Research Laboratory have developed a high-sensitivity two-color interferometer that is presently being tested on Gamble II for future use on the Sandia RITS accelerator operating with a Bz diode. This diagnostic is capable of resolving a line-integrated electron density of 2×1012 cm-2, a density that might be capable of even observing the electron beam directly. This paper will present an overview of laser-based and spectroscopic diagnostics that could be used to measure plasmas found in radiographic diodes with spatial and temporal resolutions on the order of 1-5 mm and 5 ns, respectively. Plans for the use of this diagnostic on a preionized plasma cell of a paraxial diode on the Sandia RITS experiment will be discussed.

More Details

Characterization of composite rod-pinch-diode radiographic sources at 5 to 6 MV on Asterix

Digest of Technical Papers-IEEE International Pulsed Power Conference

Mosher, D.; Allen, R.J.; Commisso, R.J.; Swanekamp, S.B.; Young, F.C.; Cooperstein, G.; Vermare, C.; Delvaux, J.; Hordé, Y.; Merle, E.; Nicolas, R.; Noré, D.; Pierret, O.; Rosol, Y.R.; Tailleur, Y.; Véron, L.; Bayol, F.; Garrigues, A.; Delbos, C.; Nicot, G.; Oliver, Bryan V.; Rose, D.V.; Rovang, Dean C.; Maenchen, John E.

Composite-rod-pinch loads on Asterix consisting of hollow aluminum tubes supporting either 1-cm-long, 1-mm-diam blunt-end or tapered gold slugs, or 1.5- to 2-mm-diam gold spheres are characterized. Composite-slug loads have slightly-lower doses than the 1.6- or 2-mm-diam standard rod pinches reported elsewhere and smaller spot sizes, leading to higher measured radiographic figures-of-merit (FOM). The FOM for the gold-sphere loads is substantially-smaller than for the slug loads.

More Details

Recent development work on PIM : a Blumlein driven IVA machine

Maenchen, John E.; Kishi, Hiroshi G.; Johnson, David L.; Maenchen, John E.; Smith, Ian D.; Bailey, Vernon L.; Corcoran, Patrick A.

An IVA (inductive voltage adder) research programme at AWE began with the construction of a small scale IVA test bed named LINX and progressed to building PIM (Prototype IVA Module). The work on PIM is geared towards furnishing AWE with a range of machines operating at 1 to 4 MV that may eventually supersede, with an upgrade in performance, existing machines operating in that voltage range. PIM has a water dielectric Blumlein of 10 ohms charged by a Marx generator. This has been used to drive either one or two 1.5 MV inductive cavities and fitting a third cavity may be attempted in the future. The latest two cavity configuration is shown which requires a split oil coax to connect the two cavities in parallel. It also has a laser triggering system for initiating the Blumlein and the prepulse reduction system fitted to the output of the Blumlein. A short MITL (magnetically insulated transmission line) connects the cavities, via a vacuum pumping section, to a chamber containing an e-beam diode test load.

More Details

Retrapping studies on RITS

Hahn, Kelly D.; Welch, Dale R.; Johnson, David L.; Schamiloglu, E.; Hahn, Kelly D.; Maenchen, John E.; Cordova, S.; Molina, I.; Portillo, Salvador; Rovang, Dean C.; Oliver, Bryan V.

SNL is developing intense sources for flash x-ray radiography. The goals of the experiments presented here were to assess power flow issues and to help benchmark the LSP particle-in-cell code used to design the experiment. Comparisons between LSP simulations and experimental data are presented.

More Details

Experimental Comparison of 2-3MV X-Ray Sources for Flash Radiography

Menge, Peter R.; Welch, Dale R.; Johnson, David L.; Maenchen, John E.; Olson, Craig L.; Rovang, Dean C.; Oliver, Bryan V.; Rose, David V.

High-brightness flash x-ray sources are needed for penetrating dynamic radiography for a variety of applications. Various bremsstrahlung source experiments have been conducted on the TriMeV accelerator (3MV, 60 {Omega}, 20 ns) to determine the best diode and focusing configuration in the 2-3 MV range. Three classes of candidate diodes were examined: gas cell focusing, magnetically immersed, and rod pinch. The best result for the gas cell diode was 6 rad at 1 meter from the source with a 5 mm diameter x-ray spot. Using a 0.5 mm diameter cathode immersed in a 17 T solenoidal magnetic field, the best shot produced 4.1 rad with a 2.9 mm spot. The rod pinch diode demonstrated very reproducible radiographic spots between 0.75 and 0.8 mm in diameter, producing 1.2 rad. This represents a factor of eight improvement in the TriMeV flash radiographic capability above the original gas cell diode to a figure of merit (dose/spot diameter) > 1.8 rad/mm. These results clearly show the rod pinch diode to be the choice x-ray source for flash radiography at 2-3 M V endpoint.

More Details
66 Results
66 Results