Publications

16 Results
Skip to search filters

Current transport and loss mechanisms in the Z accelerator

Physical Review Accelerators and Beams

Bennett, N.; Welch, D.R.; Jennings, C.A.; Yu, E.; Hess, Mark H.; Hutsel, B.T.; Laity, G.; Moore, James M.; Rose, D.V.; Peterson, K.; Cuneo, M.E.

A challenge for the TW-class accelerators driving Z-pinch experiments, such as Sandia National Laboratories' Z machine, is to efficiently couple power from multiple storage banks into a single multi-MA transmission line. The physical processes that lead to current loss are identified in new large-scale, multidimensional simulations of the Z machine. Kinetic models follow the range of physics occurring during a pulse, from vacuum pulse propagation to charged-particle emission and magnetically-insulated current flow to electrode plasma expansion. Simulations demonstrate that current is diverted from the load through a combination of standard transport (uninsulated charged-particle flows) and anomalous transport. Standard transport occurs in regions where the electrode current density is a few 104-105 A/cm2 and current is diverted from the load via transport without magnetic insulation. In regions with electrode current density >106 A/cm2, electrode surface plasmas develop velocity-shear instabilities and a Hall-field-related transport which scales with electron density and may, therefore, lead to increased current loss.

More Details

Experimental Results from the 1.2 ma, 2.2 m Diameter Linear Transformer Driver at Sandia National Labs

IEEE International Pulsed Power Conference

Douglass, Jonathan D.; Cuneo, M.E.; Jaramillo, Deanna M.; Johns, Owen J.; Jones, M.C.; Lucero, Diego J.; Moore, James M.; Sceiford, Matthew S.; Kiefer, Mark L.; Mulville, Thomas D.; Sullivan, Michael A.; Hutsel, Brian T.; Hohlfelder, Robert J.; Leckbee, J.J.; Stoltzfus, B.S.; Wisher, M.L.; Savage, Mark E.; Stygar, W.A.; Breden, E.W.; Calhoun, Jacob D.

Herein we describe the design, simulation and performance of a 118-GW linear transformer driver (LTD) cavity at Sandia National Laboratories. The cavity consists of 20 to 24 'Bricks'. Each brick is comprised of two 80 nF, 100 kV capacitors connected electrically in series with a custom, 200 kV, three-electrode, field-distortion gas switch. The brick capacitors are bi-polar charged to a total of 200 kV. Typical brick circuit parameters are 40 nF (two 80 nF capacitors in series) and 160 nH inductance. Over the course of over 10,000 shots the cavity generated a peak electrical current and power of 1.19 MA and 118 GW.

More Details

100 GW linear transformer driver cavity: Design, simulations, and performance

Physical Review Accelerators and Beams

Douglass, Jonathan D.; Hutsel, Brian T.; Leckbee, Joshua L.; Mulville, Thomas D.; Stoltzfus, Brian S.; Savage, Mark E.; Breden, E.W.; Calhoun, Jacob D.; Cuneo, M.E.; De Smet, Dennis J.; Hohlfelder, Robert J.; Jaramillo, Deanna M.; Johns, Owen J.; Lombrozo, Aaron C.; Lucero, Diego J.; Moore, James M.; Porter, John L.; Radovich, S.; Sceiford, Matthew S.; Sullivan, Michael A.; Walker, Charles A.; Yazzie, Nicole T.

Here we present details of the design, simulation, and performance of a 100-GW linear transformer driver (LTD) cavity at Sandia National Laboratories. The cavity consists of 20 “bricks.” Each brick is comprised of two 80 nF, 100 kV capacitors connected electrically in series with a custom, 200 kV, three-electrode, field-distortion gas switch. The brick capacitors are bipolar charged to ±100 kV for a total switch voltage of 200 kV. Typical brick circuit parameters are 40 nF capacitance (two 80 nF capacitors in series) and 160 nH inductance. The switch electrodes are fabricated from a WCu alloy and are operated with breathable air. Over the course of 6,556 shots the cavity generated a peak electrical current and power of 1.03 MA (±1.8%) and 106 GW (±3.1%). Experimental results are consistent (to within uncertainties) with circuit simulations for normal operation, and expected failure modes including prefire and late-fire events. New features of this development that are reported here in detail include: (1) 100 ns, 1 MA, 100-GW output from a 2.2 m diameter LTD into a 0.1 Ω load, (2) high-impedance solid charging resistors that are optimized for this application, and (3) evaluation of maintenance-free trigger circuits using capacitive coupling and inductive isolation.

More Details

Current Loss in 0.1 - 100 Terawatt Vacuum Transmission Lines: Experiments and Simulations

Hutsel, Brian T.; Gansz, Jacy N.; Jaramillo, Deanna M.; Lucero, Diego J.; Moore, James M.; Rose, David V.; Stygar, William S.

Current loss in magnetically insulated transmission lines (MITLs) was investigated using data from experiments conducted on Z and Mykonos. Data from experiments conducted on Z were used to optimize an ion diode current loss model that has been implemented into the transmission line circuit model of Z. Details on the current loss model and comparisons to data from Z experiments have been previously published in a peer-reviewed journal [Hutsel, et al., Phys. Rev. Accel. Beams 21, 030401]. Dedicated power flow experiments conducted on Mykonos investigated current loss in a millimeter-scale anode-cathode gap MITL operated at lineal current densities greater than 410 kA/cm and with electric field stresses in excess of 240 kV/cm where it is expected that both anode and cathode plasmas are formed. The experiment MITLs were exposed to varying vacuum conditions; including vacuum pressure at shot time, time under vacuum, and vacuum storage protocols. The results indicate that the vacuum conditions have an effect on current loss in high lineal current density MITLs.

More Details

Transmission-line-circuit model of an 85-TW, 25-MA pulsed-power accelerator

Physical Review Accelerators and Beams

Hutsel, Brian T.; Corcoran, Patrick A.; Cuneo, M.E.; Gomez, Matthew R.; Hess, Mark H.; Hinshelwood, D.D.; Jennings, C.A.; Laity, G.R.; Lamppa, Derek C.; McBride, Ryan D.; Moore, James M.; Myers, A.; Rose, D.V.; Slutz, S.A.; Stygar, William A.; Waisman, Eduardo M.; Welch, Dale R.; Whitney, B.A.

We have developed a physics-based transmission-line-circuit model of the Z pulsed-power accelerator. The 33-m-diameter Z machine generates a peak electrical power as high as 85 TW, and delivers as much as 25 MA to a physics load. The circuit model is used to design and analyze experiments conducted on Z. The model consists of 36 networks of transmission-line-circuit elements and resistors that represent each of Zs 36 modules. The model of each module includes a Marx generator, intermediate-energy-storage capacitor, laser-triggered gas switch, pulse-forming line, self-break water switches, and tri-plate transmission lines. The circuit model also includes elements that represent Zs water convolute, vacuum insulator stack, four parallel outer magnetically insulated vacuum transmission lines (MITLs), double-post-hole vacuum convolute, inner vacuum MITL, and physics load. Within the vacuum-transmission-line system the model conducts analytic calculations of current loss. To calculate the loss, the model simulates the following processes: (i) electron emission from MITL cathode surfaces wherever an electric-field threshold has been exceeded; (ii) electron loss in the MITLs before magnetic insulation has been established; (iii) flow of electrons emitted by the outer-MITL cathodes after insulation has been established; (iv) closure of MITL anode-cathode (AK) gaps due to expansion of cathode plasma; (v) energy loss to MITL conductors operated at high lineal current densities; (vi) heating of MITL-anode surfaces due to conduction current and deposition of electron kinetic energy; (vii) negative-space-charge-enhanced ion emission from MITL anode surfaces wherever an anode-surface-temperature threshold has been exceeded; and (viii) closure of MITL AK gaps due to expansion of anode plasma. The circuit model is expected to be most accurate when the fractional current loss is small. We have performed circuit simulations of 52 Z experiments conducted with a variety of accelerator configurations and load-impedance time histories. For these experiments, the apparent fractional current loss varies from 0% to 20%. Results of the circuit simulations agree with data acquired on 52 shots to within 2%.

More Details

Impedance-matched Marx generators

Physical Review Accelerators and Beams

Stygar, William A.; LeChien, K.R.; Mazarakis, Michael G.; Savage, Mark E.; Stoltzfus, Brian S.; Austin, Kevin N.; Breden, E.W.; Cuneo, M.E.; Hutsel, Brian T.; Lewis, S.A.; McKee, G.R.; Moore, James M.; Mulville, Thomas D.; Muron, David J.; Reisman, David R.; Sceiford, Matthew S.; Wisher, Matthew L.

We have conceived a new class of prime-power sources for pulsed-power accelerators: impedance-matched Marx generators (IMGs). The fundamental building block of an IMG is a brick, which consists of two capacitors connected electrically in series with a single switch. An IMG comprises a single stage or several stages distributed axially and connected in series. Each stage is powered by a single brick or several bricks distributed azimuthally within the stage and connected in parallel. The stages of a multistage IMG drive an impedance-matched coaxial transmission line with a conical center conductor. When the stages are triggered sequentially to launch a coherent traveling wave along the coaxial line, the IMG achieves electromagnetic-power amplification by triggered emission of radiation. Hence a multistage IMG is a pulsed-power analogue of a laser. To illustrate the IMG approach to prime power, we have developed conceptual designs of two ten-stage IMGs with LC time constants on the order of 100 ns. One design includes 20 bricks per stage, and delivers a peak electrical power of 1.05 TW to a matched-impedance 1.22-Ω load. The design generates 113 kV per stage and has a maximum energy efficiency of 89%. The other design includes a single brick per stage, delivers 68 GW to a matched-impedance 19-Ω load, generates 113 kV per stage, and has a maximum energy efficiency of 90%. For a given electrical-power-output time history, an IMG is less expensive and slightly more efficient than a linear transformer driver, since an IMG does not use ferromagnetic cores.

More Details

Conceptual design of a 10 13 -W pulsed-power accelerator for megajoule-class dynamic-material-physics experiments

Physical Review Accelerators and Beams

Stygar, William A.; Reisman, David R.; Stoltzfus, Brian S.; Austin, Kevin N.; Benage, John F.; Breden, E.W.; Cooper, R.A.C.; Cuneo, M.E.; Davis, Jean-Paul D.; Ennis, J.B.E.; Gard, Paul D.; Greiser, G.W.G.; Gruner, Frederick R.; Haill, Thomas A.; Hutsel, Brian T.; Jones, Peter A.; LeChien, K.R.L.; Leckbee, Joshua L.; Lucero, Diego J.; McKee, George R.; Moore, James M.; Mulville, Thomas D.; Muron, David J.; Root, Seth R.; Savage, Mark E.; Sceiford, Matthew S.; Spielman, R.B.S.; Waisman, Eduardo M.; Wisher, Matthew L.

In this study, we have developed a conceptual design of a next-generation pulsed-power accelerator that is optmized for driving megajoule-class dynamic-material-physics experiments at pressures as high as 1 TPa. The design is based on an accelerator architecture that is founded on three concepts: single-stage electrical-pulse compression, impedance matching, and transit-time-isolated drive circuits. Since much of the accelerator is water insulated, we refer to this machine as Neptune. The prime power source of Neptune consists of 600 independent impedance-matched Marx generators. As much as 0.8 MJ and 20 MA can be delivered in a 300-ns pulse to a 16-mΩ physics load; hence Neptune is a megajoule-class 20-MA arbitrary waveform generator. Neptune will allow the international scientific community to conduct dynamic equation-of-state, phase-transition, mechanical-property, and other material-physics experiments with a wide variety of well-defined drive-pressure time histories. Because Neptune can deliver on the order of a megajoule to a load, such experiments can be conducted on centimeter-scale samples at terapascal pressures with time histories as long as 1 μs.

More Details

Millimeter-gap magnetically insulated transmission line power flow experiments

Digest of Technical Papers-IEEE International Pulsed Power Conference

Hutsel, Brian T.; Stoltzfus, Brian S.; Breden, E.W.; Fowler, W.E.; Jones, Peter A.; Justus, D.W.; Long, Finis W.; Lucero, Diego J.; Macrunnels, K.A.; Mazarakis, Michael G.; Mckenney, John M.; Moore, James M.; Mulville, Thomas D.; Porter, John L.; Savage, Mark E.; Stygar, William A.

An experiment platform has been designed to study vacuum power flow in magnetically insulated transmission lines (MITLs) the platform is driven by the Mykonos-V LTD accelerator to drive a coaxial MITL with a millimeter-scale anode-cathode gap the experiments conducted quantify the current loss in the MITL with respect to vacuum pumpdown time and vacuum pressure. MITL gaps between 1.0 mm and 1.3 mm were tested the experiment results revealed large differences in performance for the 1.0 and 1.3 mm gaps the 1.0 mm gap resulted in current losses of 40%-60% of the peak current the 1.3 mm gap resulted in current losses of less than 5% of peak current. Classical MITL models that neglect plasma expansion predict that there should be zero current loss, after magnetic insulation is established, for both of these gaps.

More Details

Voltage measurements at the vacuum post-hole convolute of the Z pulsed-power accelerator

Physical Review Special Topics - Accelerators and Beams

Waisman, E.M.; McBride, Ryan D.; Cuneo, M.E.; Wenger, D.F.; Fowler, W.E.; Johnson, W.A.; Basilio, Lorena I.; Coats, Rebecca S.; Jennings, C.A.; Sinars, Daniel S.; Vesey, Roger A.; Jones, Brent M.; Ampleford, David A.; Lemke, Raymond W.; Martin, M.R.; Schrafel, P.C.; Lewis, S.A.; Moore, James M.; Savage, Mark E.; Stygar, William A.

Presented are voltage measurements taken near the load region on the Z pulsed-power accelerator using an inductive voltage monitor (IVM). Specifically, the IVM was connected to, and thus monitored the voltage at, the bottom level of the accelerator's vacuum double post-hole convolute. Additional voltage and current measurements were taken at the accelerator's vacuum-insulator stack (at a radius of 1.6 m) by using standard D-dot and B-dot probes, respectively. During postprocessing, the measurements taken at the stack were translated to the location of the IVM measurements by using a lossless propagation model of the Z accelerator's magnetically insulated transmission lines (MITLs) and a lumped inductor model of the vacuum post-hole convolute. Across a wide variety of experiments conducted on the Z accelerator, the voltage histories obtained from the IVM and the lossless propagation technique agree well in overall shape and magnitude. However, large-amplitude, high-frequency oscillations are more pronounced in the IVM records. It is unclear whether these larger oscillations represent true voltage oscillations at the convolute or if they are due to noise pickup and/or transit-time effects and other resonant modes in the IVM. Results using a transit-time-correction technique and Fourier analysis support the latter. Regardless of which interpretation is correct, both true voltage oscillations and the excitement of resonant modes could be the result of transient electrical breakdowns in the post-hole convolute, though more information is required to determine definitively if such breakdowns occurred. Despite the larger oscillations in the IVM records, the general agreement found between the lossless propagation results and the results of the IVM shows that large voltages are transmitted efficiently through the MITLs on Z. These results are complementary to previous studies [R.D. McBride et al., Phys. Rev. ST Accel. Beams 13, 120401 (2010)] that showed efficient transmission of large currents through the MITLs on Z. Taken together, the two studies demonstrate the overall efficient delivery of very large electrical powers through the MITLs on Z.

More Details

Integration of MHD load models with circuit representations the Z generator

Ampleford, David A.; Savage, Mark E.; Moore, James M.; Jones, Brent M.; McBride, Ryan D.; Bailey, James E.; Jones, Michael J.; Gomez, Matthew R.; Cuneo, M.E.; Nakhleh, Charles N.; Stygar, William A.

MHD models of imploding loads fielded on the Z accelerator are typically driven by reduced or simplified circuit representations of the generator. The performance of many of the imploding loads is critically dependent on the current and power delivered to them, so may be strongly influenced by the generators response to their implosion. Current losses diagnosed in the transmission lines approaching the load are further known to limit the energy delivery, while exhibiting some load dependence. Through comparing the convolute performance of a wide variety of short pulse Z loads we parameterize a convolute loss resistance applicable between different experiments. We incorporate this, and other current loss terms into a transmission line representation of the Z vacuum section. We then apply this model to study the current delivery to a wide variety of wire array and MagLif style liner loads.

More Details
16 Results
16 Results