Performance Evaluation of a Prototype Moving Packed-Bed Particle/sCO2 Heat Exchanger

Albrecht, Kevin J.; Laubscher, Hendrik F.; Bowen, Christopher P.; Ho, Clifford K.

Particle heat exchangers are a critical enabling technology for next generation concentrating solar power (CSP) plants that use supercritical carbon dioxide (sCO2) as a working fluid. This report covers the design, manufacturing and testing of a prototype particle-to-sCO2 heat exchanger targeting thermal performance levels required to meet commercial scale cost targets. In addition, the the design and assembly of integrated particle and sCO2 flow loops for heat exchanger performance testing are detailed. The prototype heat exchanger was tested to particle inlet temperatures of 500 °C at 17 MPa which resulted in overall heat transfer coefficients of approximately 300 W/m2-K at the design point and cases using high approach temperature with peak values as high as 400 W/m2-K

More Details

Receiver outlet temperature control for falling particle receiver applications

Proceedings of the ASME 2021 15th International Conference on Energy Sustainability, ES 2021

Schroeder, Nathan; Laubscher, Hendrik F.; Mills, Brantley; Ho, Clifford K.

Falling particle receivers (FPRs) are being studied in concentrating solar power applications to enable high temperatures for supercritical CO2 (sCO2) Brayton power cycles. The falling particles are introduced into the cavity receiver via a linear actuated slide gate and irradiated by concentrated sunlight. The thickness of the particle curtain associated with the slide-gate opening dimension dictates the mass flow rate of the particle curtain. A thicker, higher mass flow rate, particle curtain would typically be associated with a smaller temperature rise through the receiver, and a thinner, lower mass flow rate, particle curtain would result in a larger temperature rise. Using the receiver outlet temperature as the process variable and the linear actuated slide gate as the input parameter a proportional, integral, and derivative (PID) controller was implemented to control the temperature of the particles leaving the receiver. The PID parameters were tuned to respond in a quick and stable manner. The PID controlled slide gate was tested using the 1 MW receiver at the National Solar Thermal Test Facility (NSTTF). The receiver outlet temperature was ramped from ambient to 800°C then maintained at the setpoint temperature. After reaching a steady-state, perturbations of 15%-20% of the initial power were applied by removing heliostats to simulate passing clouds. The PID controller reacted to the change in the input power by adjusting the mass flow rate through the receiver to maintain a constant receiver outlet temperature. A goal of ±2σ ≤ 10°C in the outlet temperature for the 5 minutes following the perturbation was achieved.

More Details

Development and testing of a 20 KW moving packed-bed particle-to-SCO2 heat exchanger and test facility

Proceedings of the ASME 2021 15th International Conference on Energy Sustainability, ES 2021

Albrecht, Kevin J.; Laubscher, Hendrik F.; Carlson, Matthew D.; Ho, Clifford K.

This paper describes the development of a facility for evaluating the performance of small-scale particle-to-sCO2 heat exchangers, which includes an isobaric sCO2 flow loop and an electrically heated particle flow loop. The particle flow loop is capable of delivering up to 60 kW of heat at a temperature of 600°C and flow rate of 0.4 kg/s. The loop was developed to facilitate long duration off-sun testing of small prototype heat exchangers to produce model validation data at steady-state operating conditions. Lessons learned on instrumentation, control, and system integration from prior testing of larger heat exchangers with solar thermal input were used to guide the design of the test facility. In addition, the development and testing of a novel 20-kWt moving packed-bed particle-to-sCO2 heat exchanger using the integrated flow loops is reported. The prototype heat exchanger implements many novel features for increasing thermal performance and reducing pressure drop which include integral porting of the sCO2 flow, unique bond/braze manufacturing, narrow plate spacing, and pure counter-flow arrangement. The experimental data collected for the prototype heat exchanger was compared to model predictions to verify the sizing, thermal performance, and pressure drop which will be extended to multi-megawatt heat exchanger designs in the future.

More Details

High-Temperature Particle Heat Exchanger for sCO2 Power Cycles [Award 30342]

Carlson, Matthew D.; Albrecht, Kevin J.; Ho, Clifford K.; Laubscher, Hendrik F.; Alvarez, Francisco

This report describes the design, development, and testing of a prototype 100 kWt particle-to-supercritical CO2 (sCO2) heat exchanger. An analytic hierarchy process was implemented to compare and evaluate alternative heat-exchanger designs (fluidized bed, shell-and-plate moving packed bed, and shell-and-tube moving packed bed) that could meet the high pressure (≥ 20 MPa) and high temperature (≥ 700 °C) operational requirements associated with sCO2 power cycles. Cost, heat-transfer coefficient, structural reliability, manufacturability, parasitics and heat losses, scalability, compatibility, erosion and corrosion, transient operation, and inspection ease were considered in the evaluation. A 100 kWt shell-and-plate design was selected for construction and integration with Sandia’s falling particle receiver system that heats the particles using concentrated sunlight. Sandia worked with industry to design and construct the moving packed-bed shell-and-plate heat exchanger. Tests were performed to evaluate its performance using both electrical heating and concentrated sunlight to heat the particles. Overall heat transfer coefficients at off-design conditions (reduced operating temperatures and only three stainless steel banks in the counter-crossflow heat exchanger) were measured to be approximately ~25 - 70 W/m2-K, significantly lower than simulated values of >100 W/m2-K. Tests using the falling particle receiver to heat the particles with concentrated sunlight yielded overall heat transfer coefficients of ~35 – 80 W/m2-K with four banks (including a nickel-alloy bank above the three stainless steel banks). The overall heat transfer coefficient was observed to decrease with increasing particle inlet temperatures, which contrasted the results of simulations that showed an increase in heat transfer coefficient with temperature due to increased effective particle-bed thermal conductivity from radiation. The likely cause of the discrepancy was particle-flow maldistributions and funnel flow within the heat exchanger caused by internal ledges and cross-bracing, which could have been exacerbated by increased particle-wall friction at higher temperatures. Additional heat loss at higher temperatures may also contribute to a lower overall heat-transfer coefficient. Design challenges including pressure drop, particle and sCO2 flow maldistribution, and reduced heat transfer coefficient are discussed with approaches for mitigation in future designs. Lessons learned regarding instrumentation, performance characterization, and operation of particle components and sCO2 flow loops are also discussed. Finally, a 200 MWt commercial-scale shell-and-plate heat-exchanger design based on the concepts investigated in this report is proposed.

More Details

High-temperature particle flow testing in parallel plates for particle-to-supercritical Co2 heat exchanger applications

ASME 2020 14th International Conference on Energy Sustainability, ES 2020

Laubscher, Hendrik F.; Albrecht, Kevin J.; Ho, Clifford K.

Realizing cost-effective, dispatchable, renewable energy production using concentrated solar power (CSP) relies on reaching high process temperatures to increase the thermal-to-electrical efficiency. Ceramic based particles used as both the energy storage medium and heat transfer fluid is a promising approach to increasing the operating temperature of next generation CSP plants. The particle-to-supercritical CO2 (sCO2) heat exchanger is a critical component in the development of this technology for transferring thermal energy from the heated ceramic particles to the sCO2 working fluid of the power cycle. The leading design for the particle-to-sCO2 heat exchanger is a shell-and-plate configuration. Currently, design work is focused on optimizing the performance of the heat exchanger through reducing the plate spacing. However, the particle channel geometry is limited by uniformity and reliability of particle flow in narrow vertical channels. Results of high temperature experimental particle flow testing are presented in this paper.

More Details