Gas switch development for application in Z refurbishment (ZR) has continued since PPPS Conference 2001. Several iterations have been tested both in oil and water dielectrics. The first switch tested was an evolved version of the Sandia designed HERMES III switch. The 6MV ZR Baseline Switch consists of a self-breakdown (cascade) section in which the discharge current flows in several parallel channels, and a trigger section where the current flows through a single spark channel. The second switch tested is a Cantilevered Switch. The entire cascade section is cantilevered on a plastic support rod allowing for a single continuous insulator housing but having the same characteristics as the Baseline. The third switch tested is a Sandia Hybrid switch. The laser triggered section of the Hybrid switch includes 5 Cascade like electrodes connected in parallel to a triggered gap via a ∼2μH series isolation inductor. The discharge current in the Hybrid switch trigger section flows in several parallel channels eliminating the single channel flow as in the Baseline Switch trigger section. The design iterations of these switches and results of these tests are presented.
As part of a continuous research effort into advanced flash radiographic sources using intense electron beams, Sandia National Laboratories (SNL) has been investigating coupling vacuum power flow into various high power diodes. Of key importance is the issue of the re-trapping of electrons from the sheath current of a magnetically insulated vacuum transmission line (MITL) into the diode load. Results of electron re-trapping studies on a large area diode (LAD) on the RITS-3 accelerator are presented here. RITS-3 is a 4.5 MV, 160 kA inductive voltage adder pulsed power accelerator. Results show that re-trapping of the sheath current does occur and compares favorably with particle in cell (PIC) predictions of the LSP modeling code.
RITS (Radiographic Integrated Test Stand) is planned to be a 12-cell, 16-MV, 150-kA, 70-ns induction voltage adder. A three-cell, 4-MV, 150-kA, 70-ns version (RITS-3) is operating routinely at its specified level at Sandia. Its over-all performance will be described. Advances have been made in understanding and modeling many of the pulsed power features of RITS and several fundamental accelerator design guidelines have been developed. We summerize these. We omit discussion of vacuum power flow and symmetrization, which are the subject of other detailed papers. Subjects include: performance and redesign of the input oil-water diaphram of the pulse forming line (PFL); water switch losses; prepulse measurements at the cell; high voltages breakdowns; and impacts on the induction cell risetime due to the current-symmetrizing azimuthal oil line and the vacuum injection to the magnetically insulated output tranmission line.
An IVA (inductive voltage adder) research programme at AWE began with the construction of a small scale IVA test bed named LINX and progressed to building PIM (Prototype IVA Module). The work on PIM is geared towards furnishing AWE with a range of machines operating at 1 to 4 MV that may eventually supersede, with an upgrade in performance, existing machines operating in that voltage range. PIM has a water dielectric Blumlein of 10 ohms charged by a Marx generator. This has been used to drive either one or two 1.5 MV inductive cavities and fitting a third cavity may be attempted in the future. The latest two cavity configuration is shown which requires a split oil coax to connect the two cavities in parallel. It also has a laser triggering system for initiating the Blumlein and the prepulse reduction system fitted to the output of the Blumlein. A short MITL (magnetically insulated transmission line) connects the cavities, via a vacuum pumping section, to a chamber containing an e-beam diode test load.
SNL is developing intense sources for flash x-ray radiography. The goals of the experiments presented here were to assess power flow issues and to help benchmark the LSP particle-in-cell code used to design the experiment. Comparisons between LSP simulations and experimental data are presented.
High-brightness flash x-ray sources are needed for penetrating dynamic radiography for a variety of applications. Various bremsstrahlung source experiments have been conducted on the TriMeV accelerator (3MV, 60 {Omega}, 20 ns) to determine the best diode and focusing configuration in the 2-3 MV range. Three classes of candidate diodes were examined: gas cell focusing, magnetically immersed, and rod pinch. The best result for the gas cell diode was 6 rad at 1 meter from the source with a 5 mm diameter x-ray spot. Using a 0.5 mm diameter cathode immersed in a 17 T solenoidal magnetic field, the best shot produced 4.1 rad with a 2.9 mm spot. The rod pinch diode demonstrated very reproducible radiographic spots between 0.75 and 0.8 mm in diameter, producing 1.2 rad. This represents a factor of eight improvement in the TriMeV flash radiographic capability above the original gas cell diode to a figure of merit (dose/spot diameter) > 1.8 rad/mm. These results clearly show the rod pinch diode to be the choice x-ray source for flash radiography at 2-3 M V endpoint.