Uncertainty in annual energy resulting from uncertain irradiance measurements
Abstract not provided.
Abstract not provided.
The PV Operations and Maintenance (O&M) service industry lacks an affordable, well-documented, intuitive PV modeling and analytics tool to calculate modeled performance from actual data from multiple data acquisition systems (DAS). We envision a performance modeling and analytics platform built on open-source, extensible, community-maintained code. The key innovation is the community-driven development of pvlib python delivered through a lightweight web service to provide configurable, consistent and reproducible PV modeling for O&M providers.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
The Waste Isolation Pilot Plant (WIPP) facility is a U.S. Department of Energy (DOE) operating repository 654 m below the surface in a thick salt formation in southeastern New Mexico. The DOE disposes transuranic (TRU) waste produced from atomic energy defense activities at the WIPP facility. A portion of the waste shipped to the WIPP facility contains TRU radionuclides co-mingled with polychlorinated biphenyls (PCBs), which fall under U.S. Environmental Protection Agency (EPA) regulations implementing the Toxic Substances Control Act (TSCA). This report documents the risks of PCBs co-mingled with TRU waste (hereafter designated as PCB/TRU waste) designated for disposal at the WIPP facility. This analysis is input to the National Environmental Policy Act (NEPA) assessment by the DOE Carlsbad Field Office (CBFO) for the proposed increase of the WIPP facility disposal area to include additional waste panels (but not to increase the legislated WIPP volume). This analysis is not a compliance calculation to support a certification renewal nor does it support a planned change request (PCR) or planned change notice (PCN) to be submitted to the EPA.
Sandia National Laboratories sponsored a three-year internally funded Laboratory Directed Research and Development (LDRD) effort to investigate the vulnerabilities and mitigations of a high-altitude electromagnetic pulse (HEMP) on the electric power grid. The research was focused on understanding the vulnerabilities and potential mitigations for components and systems at the high voltage transmission level. Results from the research included a broad array of subtopics, covered in twenty-three reports and papers, and which are highlighted in this executive summary report. These subtopics include high altitude electromagnetic pulse (HEMP) characterization, HEMP coupling analysis, system-wide effects, and mitigating technologies.
Abstract not provided.
Energies
Grid operators are now considering using distributed energy resources (DERs) to provide distribution voltage regulation rather than installing costly voltage regulation hardware. DER devices include multiple adjustable reactive power control functions, so grid operators have the difficult decision of selecting the best operating mode and settings for the DER. In this work, we develop a novel state estimation-based particle swarm optimization (PSO) for distribution voltage regulation using DER-reactive power setpoints and establish a methodology to validate and compare it against alternative DER control technologies (volt-VAR (VV), extremum seeking control (ESC)) in increasingly higher fidelity environments. Distribution system real-time simulations with virtualized and power hardware-in-the-loop (PHIL)-interfaced DER equipment were run to evaluate the implementations and select the best voltage regulation technique. Each method improved the distribution system voltage profile; VV did not reach the global optimum but the PSO and ESC methods optimized the reactive power contributions of multiple DER devices to approach the optimal solution.
Understanding the effect of a high-altitude electromagnetic pulse (HEMP) on the equipment in the United States electrical power grid is important to national security. A present challenge to this understanding is evaluating the vulnerability of transformers to a HEMP. Evaluating vulnerability by direct testing is cost-prohibitive, due to the wide variation in transformers, their high cost, and the large number of tests required to establish vulnerability with confidence. Alternatively, material and component testing can be performed to quantify a model for transformer failure, and the model can be used to assess vulnerability of a wide variety of transformers. This project develops a model of the probability of equipment failure due to effects of a HEMP. Potential failure modes are cataloged, and a model structure is presented which can be quantified by the results of small-scale coupon tests.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
IET Generation, Transmission and Distribution
While the concept of aggregating and controlling renewable distributed energy resources (DERs) to provide grid services is not new, increasing policy support of DER market participation has driven research and development in algorithms to pool DERs for economically viable market participation. Sandia National Laboratories recently undertook a 3 year research programme to create the components of a real-world virtual power plant (VPP) that can simultaneously participate in multiple markets. The authors' research extends current state-of-the-art rolling horizon control through the application of stochastic programming with risk aversion at various time resolutions. Their rolling horizon control consists of day-ahead optimisation to produce an hourly aggregate schedule for the VPP operator and sub-hourly optimisation for the real-time dispatch of each VPP subresource. Both optimisation routines leverage a two-stage stochastic programme with risk aversion and integrate the most up-to-date forecasts to generate probabilistic scenarios in real operating time. Their results demonstrate the benefits to the VPP operator of constructing a stochastic solution regardless of the weather. In more extreme weather, applying risk optimisation strategies can dramatically increase the financial viability of the VPP. The methodologies presented here can be further tailored for optimal control of any VPP asset fleet and its operational requirements.
Conference Record of the IEEE Photovoltaic Specialists Conference
In this paper, we present a new, light-weight approach for extracting the five single diode parameters (IL, Io, RS, RSH, and nNsVt) for advanced, in-field monitoring of in situ current and voltage (I-V) tracing devices. The proposed procedure uses individual I-V curves, and does not require the irradiance or module temperature measurement to calculate the parameters. It is suitable for operation on a small, single board computer at the point of I-V curve measurement. This allows for analysis to occur in the field, and eliminates the need to transfer large amounts of data to centralized databases. Observers can receive alerts directly from the in-field devices based on the extraction, and analysis of the commonly used single diode equivalent model parameters. This paper defines the approach and evaluates its accuracy by subjecting it to I-V curves with known parameters. Its performance is defined using actual I-V curves generated from an in situ scanning devices installed within an actual photovoltaic production field. The algorithm is able to operate at a high accuracy for multiple module types and performed well on actual curves extracted in the field.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
IEEE Journal of Photovoltaics
Literature describes various methods for determining a series resistance for a photovoltaic device from measured IV curves. We investigate use of these techniques to estimate the series resistance parameter for a single diode equivalent circuit model. With simulated IV curves we demonstrate that the series resistance values obtained by these techniques differ systematically from the known series resistance parameter values used to generate the curves, indicating that these methods are not suitable for determining the series resistance parameter for the single diode model equation. We present an alternative method to determine the series resistance parameter jointly with the other parameters for the single diode model equation, and demonstrate the accuracy and reliability of this technique in the presence of measurement errors.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.