Publications

18 Results
Skip to search filters

Gram scale synthesis of Fe/FexOy core-shell nanoparticles and their incorporation into matrix-free superparamagnetic nanocomposites

Journal of Materials Research

Watt, John D.; Bleier, Grant C.; Romero, Zachary W.; Hance, Bradley G.; Bierner, Jessica A.; Monson, Todd M.; Huber, Dale L.

Significant reductions recently seen in the size of wide-bandgap power electronics have not been accompanied by a relative decrease in the size of the corresponding magnetic components. To achieve this, a new generation of materials with high magnetic saturation and permeability are needed. Here, we develop gram-scale syntheses of superparamagnetic Fe/FexOy core-shell nanoparticles and incorporate them as the magnetic component in a strongly magnetic nanocomposite. Nanocomposites are typically formed by the organization of nanoparticles within a polymeric matrix. However, this approach can lead to high organic fractions and phase separation; reducing the performance of the resulting material. Here, we form aminated nanoparticles that are then cross-linked using epoxy chemistry. The result is a magnetic nanoparticle component that is covalently linked and well separated. By using this 'matrix-free' approach, we can substantially increase the magnetic nanoparticle fraction, while still maintaining good separation, leading to a superparamagnetic nanocomposite with strong magnetic properties.

More Details

Enhanced Nanoparticle Size Control by Extending LaMer's Mechanism

Chemistry of Materials

Vreeland, Erika C.; Watt, John D.; Schober, Gretchen B.; Hance, Bradley G.; Austin, Mariah A.; Price, Andrew D.; Fellows, Benjamin D.; Monson, Todd M.; Hudak, Nicholas S.; Maldonado-Camargo, Lorena; Bohorquez, Ana C.; Rinaldi, Carlos; Huber, Dale L.

The synthesis of well-defined nanoparticle materials has been an area of intense investigation, but size control in nanoparticle syntheses is largely empirical. Here, we introduce a general method for fine size control in the synthesis of nanoparticles by establishing steady state growth conditions through the continuous, controlled addition of precursor, leading to a uniform rate of particle growth. This approach, which we term the "xtended LaMer mechanism" allows for reproducibility in particle size from batch to batch as well as the ability to predict nanoparticle size by monitoring the early stages of growth. We have demonstrated this method by applying it to a challenging synthetic system: magnetite nanoparticles. To facilitate this reaction, we have developed a reproducible method for synthesizing an iron oleate precursor that can be used without purification. We then show how such fine size control affects the performance of magnetite nanoparticles in magnetic hyperthermia.

More Details

Tunable young's modulus in carbon MEMS using graphene-based stiffeners

ECS Transactions

Washburn, C.M.; Lambert, Timothy N.; Blecke, Jill B.; Davis, D.; Finnegan, Patrick S.; Hance, Bradley G.; Wheeler, D.R.; Beechem, T.E.; Alam, T.M.; Brumbach, M.T.; Strong, J.M.

Carbon composite micro-electromechanical systems (C-MEMS) incorporating 2 wt.% graphene stiffeners show a 65% increase in Young's modulus and 11% increase in conductivity. An improved reduced graphene oxide (iRGO), is blended into pyrolytic carbon beams prepared for resonant frequency testing. Designed around a 10:1 (length: width) aspect ratio, the linearity of wt.% iRGO in the cantilevers as a function of resonant frequencies is evaluated. The collection of the 1st through 3rd bending modes using laser doppler velocimetery (LDV) of the graphene filled cantilevers shows an increase in frequency response with nanomaterial loading (wt.%). A model was developed using the 3-bending modes and correlated with cross sectional geometry and density to extract a Young's modulus. © 2012 The Electrochemical Society.

More Details

Microcalibrator system for chemical signature and reagent delivery

Simonson, Robert J.; Rawlinson, Kim S.; Robinson, Alex L.; Ellison, Jennifer A.; Staton, Alan W.; Manginell, Ronald P.; Adkins, Douglas R.; Sokolowski, Sara S.; Hance, Bradley G.

Networked systems of low-cost, small, integrable chemical sensors will enable monitoring of Nonproliferation and Materials Control targets and chemical weapons threats. Sandia-designed prototype chemical sensor systems are undergoing extended field testing supported by DOE and other government agencies. A required surety component will be verification of microanalytical system performance, which can be achieved by providing a programmable source of chemical signature(s) for autonomous calibration of analytical systems. In addition, such a controlled chemical source could be used to dispense microaliquots of derivatization reagents, extending the analysis capability of chemical sensors to a wider range of targets. We have developed a microfabricated system for controlled release of selected compounds (calibrants) into the analytical stream of microsensor systems. To minimize pumping and valve requirements of microfluidic systems, and to avoid degradation issues associated with storage of dilute solutions, we have utilized thermally labile organic salts as solid-phase reservoir materials. Reproducible deposition of tetrapropyl ammonium hydroxide onto arrays of microfabricated heating elements can provide a pair of calibration marker compounds (one fast and one slow-eluting compound) for GC analyses. The use of this microaliquot gas source array for hydrogen generation is currently under further development. The goal of the latter effort will be to provide a source of high-pressure, low viscosity GC carrier gas for Sandia's next-generation microfabricated gas-phase chemical analysis systems.

More Details

Distributed Sensor Particles for Remote Fluorescence Detection of Trace Analytes: UXO/CW

Singh, Anup K.; Schmitt, Randal L.; Johnson, Mark S.; Hargis, Philip J.; Simonson, Robert J.; Simonson, Robert J.; Schoeniger, Joseph S.; Ashley, Carol S.; Brinker, C.J.; Hance, Bradley G.

This report summarizes the development of sensor particles for remote detection of trace chemical analytes over broad areas, e.g residual trinitrotoluene from buried landmines or other unexploded ordnance (UXO). We also describe the potential of the sensor particle approach for the detection of chemical warfare (CW) agents. The primary goal of this work has been the development of sensor particles that incorporate sample preconcentration, analyte molecular recognition, chemical signal amplification, and fluorescence signal transduction within a ''grain of sand''. Two approaches for particle-based chemical-to-fluorescence signal transduction are described: (1) enzyme-amplified immunoassays using biocompatible inorganic encapsulants, and (2) oxidative quenching of a unique fluorescent polymer by TNT.

More Details

IMS applications analysis

Rodacy, Philip J.; Reber, Stephen D.; Simonson, Robert J.; Hance, Bradley G.

This report examines the market potential of a miniature, hand-held Ion Mobility Spectrometer. Military and civilian markets are discussed, as well as applications in a variety of diverse fields. The strengths and weaknesses of competing technologies are discussed. An extensive Ion Mobility Spectrometry (IMS) bibliography is included. The conclusions drawn from this study are: (1) There are a number of competing technologies that are capable of detecting explosives, drugs, biological, or chemical agents. The IMS system currently represents the best available compromise regarding sensitivity, specificity, and portability. (2) The military market is not as large as the commercial market, but the military services are more likely to invest R and D funds in the system. (3) Military applications should be addressed before commercial applications are addressed. (4) There is potentially a large commercial market for rugged, hand-held Ion Mobility Spectrometer systems. Commercial users typically do not invest R and D funds in this type of equipment rather, they wait for off-the-shelf availability.

More Details
18 Results
18 Results