Publications

Results 1–25 of 28
Skip to search filters

An overview of magneto-inertial fusion on the Z machine at Sandia National Laboratories

Nuclear Fusion

Yager-Elorriaga, David A.; Gomez, M.R.; Ruiz, D.E.; Slutz, S.A.; Harvey-Thompson, Adam J.; Jennings, C.A.; Knapp, P.F.; Schmit, P.F.; Weis, M.R.; Awe, T.J.; Chandler, Gordon A.; Mangan, M.; Myers, C.E.; Fein, Jeffrey R.; Galloway, B.R.; Geissel, Matthias G.; Glinsky, Michael E.; Hansen, Stephanie B.; Harding, Eric H.; Lamppa, Derek C.; Lewis, W.E.; Rambo, Patrick K.; Robertson, Grafton K.; Savage, Mark E.; Shipley, Gabriel A.; Smith, I.C.; Schwarz, Jens S.; Ampleford, David A.; Beckwith, Kristian B.; Peterson, Kyle J.; Porter, John L.; Rochau, G.A.; Sinars, D.B.

We present an overview of the magneto-inertial fusion (MIF) concept Magnetized Liner Inertial Fusion (MagLIF) pursued at Sandia National Laboratories and review some of the most prominent results since the initial experiments in 2013. In MagLIF, a centimeter-scale beryllium tube or 'liner' is filled with a fusion fuel, axially pre-magnetized, laser pre-heated, and finally imploded using up to 20 MA from the Z machine. All of these elements are necessary to generate a thermonuclear plasma: laser preheating raises the initial temperature of the fuel, the electrical current implodes the liner and quasi-adiabatically compresses the fuel via the Lorentz force, and the axial magnetic field limits thermal conduction from the hot plasma to the cold liner walls during the implosion. MagLIF is the first MIF concept to demonstrate fusion relevant temperatures, significant fusion production (>1013 primary DD neutron yield), and magnetic trapping of charged fusion particles. On a 60 MA next-generation pulsed-power machine, two-dimensional simulations suggest that MagLIF has the potential to generate multi-MJ yields with significant self-heating, a long-term goal of the US Stockpile Stewardship Program. At currents exceeding 65 MA, the high gains required for fusion energy could be achievable.

More Details

Z-Petawatt Laser Highlights for FY21

Rambo, Patrick K.; Galloway, B.R.; Geissel, Matthias G.; Kimmel, Mark W.; Porter, John L.

We’re happy to report that the full-aperture upgrade project, started in FY18, is now complete and short-pulse target experiments are underway. The table below lists the present performance level of ZPW. Additional laser improvements are in progress to increase the laser energy and pulse contrast along with implementing a correction for achromatic aberrations to reduce the focused spot size and pulse width.

More Details

Lasergate: A windowless gas target for enhanced laser preheat in magnetized liner inertial fusion

Physics of Plasmas

Galloway, B.R.; Slutz, S.A.; Kimmel, Mark W.; Rambo, Patrick K.; Schwarz, Jens S.; Geissel, Matthias G.; Harvey-Thompson, Adam J.; Weis, M.R.; Jennings, C.A.; Field, Ella S.; Kletecka, Damon E.; Looker, Q.; Colombo, Anthony P.; Edens, Aaron E.; Smith, Ian C.; Shores, J.E.; Speas, C.S.; Speas, Robert J.; Spann, A.P.; Sin, J.; Gautier, S.; Sauget, V.; Treadwell, P.A.; Rochau, G.A.; Porter, John L.

At the Z Facility at Sandia National Laboratories, the magnetized liner inertial fusion (MagLIF) program aims to study the inertial confinement fusion in deuterium-filled gas cells by implementing a three-step process on the fuel: premagnetization, laser preheat, and Z-pinch compression. In the laser preheat stage, the Z-Beamlet laser focuses through a thin polyimide window to enter the gas cell and heat the fusion fuel. However, it is known that the presence of the few μm thick window reduces the amount of laser energy that enters the gas and causes window material to mix into the fuel. These effects are detrimental to achieving fusion; therefore, a windowless target is desired. The Lasergate concept is designed to accomplish this by "cutting"the window and allowing the interior gas pressure to push the window material out of the beam path just before the heating laser arrives. In this work, we present the proof-of-principle experiments to evaluate a laser-cutting approach to Lasergate and explore the subsequent window and gas dynamics. Further, an experimental comparison of gas preheat with and without Lasergate gives clear indications of an energy deposition advantage using the Lasergate concept, as well as other observed and hypothesized benefits. While Lasergate was conceived with MagLIF in mind, the method is applicable to any laser or diagnostic application requiring direct line of sight to the interior of gas cell targets.

More Details

Lasergate: a windowless gas target for enhanced laser preheat in MagLIF

Galloway, B.R.; Slutz, Stephen A.; Kimmel, Mark W.; Rambo, Patrick K.; Schwarz, Jens S.; Geissel, Matthias G.; Harvey-Thompson, Adam J.; Weis, Matthew R.; Jennings, Christopher A.; Field, Ella S.; Kletecka, Damon E.; Looker, Quinn M.; Colombo, Anthony P.; Edens, Aaron E.; Smith, Ian C.; Shores, Jonathon S.; Speas, Christopher S.; Speas, Robert J.; Spann, Andrew S.; Sin, Justin S.; Gautier, Sophie G.; Sauget, Vincent S.; Treadwell, Paul T.; Rochau, G.A.; Porter, John L.

Abstract not provided.

Increased preheat energy to MagLIF targets with cryogenic cooling

Harvey-Thompson, Adam J.; Geissel, Matthias G.; Crabtree, Jerry A.; Weis, Matthew R.; Gomez, Matthew R.; Fein, Jeffrey R.; Ampleford, David A.; Awe, Thomas J.; Chandler, Gordon A.; Galloway, B.R.; Hansen, Stephanie B.; Hanson, Jeffrey J.; Harding, Eric H.; Jennings, Christopher A.; Kimmel, Mark W.; Knapp, Patrick K.; Lamppa, Derek C.; Lewis, William L.; Mangan, Michael M.; Maurer, A.; Perea, L.; Peterson, Kara J.; Porter, John L.; Rambo, Patrick K.; Robertson, Grafton K.; Rochau, G.A.; Ruiz, Daniel E.; Shores, Jonathon S.; Slutz, Stephen A.; Smith, Ian C.; Speas, Christopher S.; Yager-Elorriaga, David A.; York, Adam Y.; Paguio, R.R.; Smith, G.E.

Abstract not provided.

Update on MagLIF preheat experiments

Harvey-Thompson, Adam J.; Geissel, Matthias G.; Weis, Matthew R.; Galloway, B.R.; Fein, Jeffrey R.; Awe, Thomas J.; Crabtree, Jerry A.; Ampleford, David A.; Bliss, David E.; Glinsky, Michael E.; Gomez, Matthew R.; Hanson, Joseph C.; Harding, Eric H.; Jennings, Christopher A.; Kimmel, Mark W.; Perea, L.; Peterson, Kyle J.; Porter, James D.; Rambo, Patrick K.; Robertson, Grafton K.; Ruiz, Daniel E.; Schwarz, Jens S.; Shores, Jonathon S.; Slutz, Stephen A.; Smith, Ian C.; York, Adam Y.; Paguio, R.R.; Smith, G.E.; Maudlin, M.M.; Pollock, B.P.

Abstract not provided.

The Impact on Mix of Different Preheat Protocols

Harvey-Thompson, Adam J.; Geissel, Matthias G.; Jennings, Christopher A.; Weis, Matthew R.; Ampleford, David A.; Bliss, David E.; Chandler, Gordon A.; Fein, Jeffrey R.; Galloway, B.R.; Glinsky, Michael E.; Gomez, Matthew R.; Hahn, K.D.; Hansen, Stephanie B.; Harding, Eric H.; Kimmel, Mark W.; Knapp, Patrick K.; Perea, L.; Peterson, Kara J.; Porter, John L.; Rambo, Patrick K.; Robertson, Grafton K.; Rochau, G.A.; Ruiz, Daniel E.; Schwarz, Jens S.; Shores, Jonathon S.; Sinars, Daniel S.; Slutz, Stephen A.; Smith, Ian C.; Speas, Christopher S.; Whittemore, K.; Woodbury, Daniel W.; Smith, G.E.

Abstract not provided.

Progress in Implementing High-Energy Low-Mix Laser Preheat for MagLIF

Harvey-Thompson, Adam J.; Harvey-Thompson, Adam J.; Geissel, Matthias G.; Geissel, Matthias G.; Jennings, Christopher A.; Jennings, Christopher A.; Weis, Matthew R.; Weis, Matthew R.; Ampleford, David A.; Ampleford, David A.; Bliss, David E.; Bliss, David E.; Chandler, Gordon A.; Chandler, Gordon A.; Fein, Jeffrey R.; Fein, Jeffrey R.; Galloway, B.R.; Galloway, B.R.; Glinsky, Michael E.; Glinsky, Michael E.; Gomez, Matthew R.; Gomez, Matthew R.; Hahn, K.D.; Hahn, K.D.; Hansen, Stephanie B.; Hansen, Stephanie B.; Harding, Eric H.; Harding, Eric H.; Kimmel, Mark W.; Kimmel, Mark W.; Knapp, Patrick K.; Knapp, Patrick K.; Perea, L.; Perea, L.; Peterson, Kara J.; Peterson, Kara J.; Porter, John L.; Porter, John L.; Rambo, Patrick K.; Rambo, Patrick K.; Robertson, Grafton K.; Robertson, Grafton K.; Rochau, G.A.; Rochau, G.A.; Ruiz, Daniel E.; Ruiz, Daniel E.; Schwarz, Jens S.; Schwarz, Jens S.; Shores, Jonathon S.; Shores, Jonathon S.; Sinars, Daniel S.; Sinars, Daniel S.; Slutz, Stephen A.; Slutz, Stephen A.; Smith, Ian C.; Smith, Ian C.; Speas, Christopher S.; Speas, Christopher S.; Whittemore, K.; Whittemore, K.; Woodbury, Daniel W.; Woodbury, Daniel W.; Smith, G.E.; Smith, G.E.

Abstract not provided.

Dual-wavelength laser-induced damage threshold of a HfO2/SiO2 dichroic coating developed for high transmission at 527 nm and high reflection at 1054 nm

Proceedings of SPIE - The International Society for Optical Engineering

Field, Ella S.; Galloway, B.R.; Kletecka, Damon E.; Rambo, Patrick K.; Smith, Ian C.

Dichroic coatings have been developed for high transmission at 527 nm and high reflection at 1054 nm for laser operations in the nanosecond pulse regime. The coatings consist of HfO2 and SiO2 layers deposited with e-beam evaporation, and laser-induced damage thresholds as high as 12.5 J/cm2 were measured at 532 nm with 3.5 ns pulses (22.5 degrees angle of incidence, in S-polarization). However, laser damage measurements at the single wavelength of 532 nm do not adequately characterize the laser damage resistance of these coatings, since they were designed to operate at dual wavelengths simultaneously. This became apparent after one of the coatings damaged prematurely at a lower fluence in the beam train, which inspired further investigations. To gain a more complete understanding of the laser damage resistance, results of a dual-wavelength laser damage test performed at both 532 nm and 1064 nm are presented.

More Details

Polycapillary x-ray lenses for single-shot, laser-driven powder diffraction

Review of Scientific Instruments

Schollmeier, Marius; Ao, Tommy A.; Field, Ella S.; Galloway, B.R.; Kalita, Patricia K.; Kimmel, Mark W.; Morgan, D.V.; Rambo, Patrick K.; Schwarz, Jens S.; Shores, J.E.; Smith, Ian C.; Speas, C.S.; Benage, John F.; Porter, John L.

X-ray diffraction measurements to characterize phase transitions of dynamically compressed high-Z matter at Mbar pressures require both sufficient photon energy and fluence to create data with high fidelity in a single shot. Large-scale laser systems can be used to generate x-ray sources above 10 keV utilizing line radiation of mid-Z elements. However, the laser-to-x-ray energy conversion efficiency at these energies is low, and thermal x-rays or hot electrons result in unwanted background. We employ polycapillary x-ray lenses in powder x-ray diffraction measurements using solid target x-ray emission from either the Z-Beamlet long-pulse or the Z-Petawatt (ZPW) short-pulse laser systems at Sandia National Laboratories. Polycapillary lenses allow for a 100-fold fluence increase compared to a conventional pinhole aperture while simultaneously reducing the background significantly. This enables diffraction measurements up to 16 keV at the few-photon signal level as well as diffraction experiments with ZPW at full intensity.

More Details

X-Ray Diffraction Measurements on Laser-Compressed Polycrystalline Samples Using a Short-Pulse Laser Generated X-Ray Source

Schollmeier, Marius; Ao, Tommy A.; Field, Ella S.; Galloway, B.R.; Kalita, Patricia K.; Kimmel, Mark W.; Long, Joel L.; Morgan, Dane D.; Rambo, Patrick K.; Schwarz, Jens S.; Seagle, Christopher T.

Existing models for most materials do not describe phase transformations and associated lattice dy- namics (kinetics) under extreme conditions of pressure and temperature. Dynamic x-ray diffraction (DXRD) allows material investigations in situ on an atomic scale due to the correlation between solid-state structures and their associated diffraction patterns. In this LDRD project we have devel- oped a nanosecond laser-compression and picosecond-to-nanosecond x-ray diffraction platform for dynamically-compressed material studies. A new target chamber in the Target Bay in building 983 was commissioned for the ns, kJ Z-Beamlet laser (ZBL) and the 0.1 ns, 250 J Z-Petawatt (ZPW) laser systems, which were used to create 8-16 keV plasma x-ray sources from thin metal foils. The 5 ns, 15 J Chaco laser system was converted to a high-energy laser shock driver to load material samples to GPa stresses. Since laser-to-x-ray energy conversion efficiency above 10 keV is low, we employed polycapillary x-ray lenses for a 100-fold fluence increase compared to a conventional pinhole aperture while simultaneously reducing the background significantly. Polycapillary lenses enabled diffraction measurements up to 16 keV with ZBL as well as diffraction experiments with ZPW. This x-ray diffraction platform supports experiments that are complementary to gas guns and the Z facility due to different strain rates. Ultimately, there is now a foundation to evaluate DXRD techniques and detectors in-house before transferring the technology to Z. This page intentionally left blank.

More Details
Results 1–25 of 28
Results 1–25 of 28