Two-beam femtosecond rotational CARS for one-dimensional thermometry in a turbulent, sooting jet flame

Richardson, Daniel; Roy, Sukesh; Gord, James; Kearney, S.P.

Single-laser-shot femtosecond rotational coherent anti-Stokes Raman scattering (fs-RCARS) temperature measurements are performed across a 3- mm line in a turbulent, sooting ethylene jet flame to characterize temperature gradients. A 60-fs pulse is used to excite many rotational Raman transitions, and a 160-ps pulse is used to probe the Raman coherence. The spatial resolution of the measurements is 670 μm in the direction of beam propagation, 200 μm in the direction along the 1D line, and 50 μm in the transverse direction. Measurements have been performed at multiple locations in the jet flame, and the measured temperature are similar to previously recorded point measurements.