Publications
Time-resolved picosecond pure-rotational coherent anti-stokes Raman spectroscopy for thermometry and species concentration in flames
Time-resolved picosecond pure-rotational coherent anti-Stokes Raman spectroscopy is demonstrated for thermometry and species concentration determination in flames. Time-delaying the probe pulse enables successful suppression of unwanted signals. A theoretical model is under development. ©2010 Optical Society of America.