Publications

Publications / Conference

Status of the 10 MV, 120 kA RITS-6 inductive voltage adder

Johnson, D.; Bailey, V.; Altes, R.; Corcoran, P.; Smith, I.; Cordova, S.; Hahn, K.; Maenchen, John E.; Molina, I.; Portillo, Salvador; Puetz, E.; Sceiford, Matthew S.; Van De Valde, D.; Rose, D.; Oliver, B.; Welch, D.; Droemer, D.

The six-cell RITS-6 accelerator is an upgrade of the existing RITS-3 accelerator and is next in the sequence of Sandia IVA accelerators built to investigate/validate critical accelerator and radiographic diode issues for scaling to the Radiographic Integrated Test Stand (RITS) (nominally 16 MV, 156 kA, and 70 ns). In the RITS-6 upgrade to RITS-3 the number of cells/cavities, PFLs, laser triggered gas switches and intermediate stores is being doubled. A rebuilt single 61-nF Marx generator will charge the two intermediate storage capacitors. The RITS-3 experiments have demonstrated a MITL configuration matched to the PFL/induction cell impedance and a higher impedance MITL. RITS-6 is designed to utilize the higher impedance MITL providing a 10.5-MV, 123-kA output. The three years of pulsed power performance data from RITS-3 will be summarized and the design improvements being incorporated into RITS-6 will be outlined. The predicted output voltage and current for RITS-6 as a function of diode impedance will be shown. Particle-in-cell simulations of the vacuum power flow from the cell to the load for a range of diode impedances from matched to ∼40 Ohms will be shown and compared with the re-trapped parapotential flow predictions. The status of the component fabrication and system integration will be given. Another potential upgrade under consideration is RITS-62. In this case the RITS-6 Marx, intermediate stores, gas switches, and PFLs would be duplicated and a tee would replace the elbow that now connects a single PFL to a cell thereby allowing two PFLs to be connected to one cell. The output of RITS-62 matched to the cell/PFL impedance would then be 8 MV, 312 kA or 25.6 ohms. The predicted operating curves for RITS-62 with other non-matched MITLs will be shown. The power delivered to a radiographic diode can be maximized by the correct choice of MITL impedance given the cell/PFL and radiographic diode impedances. If the radiated output for a given diode has a stronger than linear voltage dependence this dependence can also be included in the correct choice of MITL impedance. The optimizations and trade-offs will be shown for RITS-6 and RITS-62 for diode impedances characteristic of radiographic diodes. © 2005 IEEE.