Publications
Spectroscopic modeling and comparison of radiation from X-pinches and wire arrays produced on the 1 MA pulsed power generator at UNR
Coverdale, Christine A.; Jones, Brent M.; Deeney, Christopher D.
X-ray spectra and images from Al (with 5% of Mg and some with 5% of NaF dopants) and Cu (pure and with 4% of Ni) wire arrays and X-pinches were accumulated in experiments on the 1 MA pulsed power generator at UNR. In particular, axially and radially resolved K-shell X-ray spectra of Al, Mg, and Na and L-shell X-ray spectra of Cu and Ni were recorded by a KAP crystal (in a spectral region from 6 to 15 Aring) through different slits from 50 mum to 3 mm. In addition, spatially integrated harder X-ray spectra were monitored by a LiF crystal. Non-LTE kinetic models of Al, Mg, and Na, and of Cu and Ni provided spatially resolved electron temperatures and densities for experiments with Al and Cu loads, respectively. Advantages of using alloys and dopants with small concentrations for spectroscopic plasma diagnostics will be presented. Dependence of the plasma's spatial structures, temperatures, and densities from wire material and load configurations, sizes, and masses will be discussed .