Publications

Publications / SAND Report

Performance Evaluation of a Prototype Moving Packed-Bed Particle/sCO2 Heat Exchanger

Albrecht, Kevin J.; Laubscher, Hendrik F.; Bowen, Christopher P.; Ho, Clifford K.

Particle heat exchangers are a critical enabling technology for next generation concentrating solar power (CSP) plants that use supercritical carbon dioxide (sCO2) as a working fluid. This report covers the design, manufacturing and testing of a prototype particle-to-sCO2 heat exchanger targeting thermal performance levels required to meet commercial scale cost targets. In addition, the the design and assembly of integrated particle and sCO2 flow loops for heat exchanger performance testing are detailed. The prototype heat exchanger was tested to particle inlet temperatures of 500 °C at 17 MPa which resulted in overall heat transfer coefficients of approximately 300 W/m2-K at the design point and cases using high approach temperature with peak values as high as 400 W/m2-K