Publications
Mechanically-induced degradation of metallic sliding electrical contacts in silicone fluid at room temperature
Dugger, Michael T.; Groysman, D.; Celina, Mathias C.; Alam, Todd M.; Argibay, Nicolas A.; Nation, Brendan L.; Prasad, Somuri V.
The degradation in electrical contact resistance of a contact pair sliding while submerged in silicone fluid has been investigated. While the contamination of electrical contacts by silicone vapors or migrating species at elevated temperature due to decomposition in electric arcs is well known, the present degradation mechanism appears to arise from chemical reactions in the silicone fluid at room temperature, catalyzed by the presence of the freshly-abraded metal surface. As a result of these reactions, a deposit containing Si, C and O forms in the vicinity of mechanical contact. The specific contact metals present and the availability of dissolved oxygen in the fluid have a dramatic influence on the quantity of reaction product formed. The chemistry of the deposit, proposed formation mechanisms, the impact on electrical contact resistance and mitigation strategies are discussed.