Publications

Publications / Journal Article

High-Speed X-Ray Stereo Digital Image Correlation in a Shock Tube

James, J.W.; Jones, Elizabeth M.; Quintana, Enrico C.; Lynch, Kyle P.; Halls, B.R.; Wagner, Justin W.

X-ray stereo digital image correlation (DIC) measurements were performed at 10 kHz on the internal surface of a jointed structure in a shock tube at a shock Mach number of 1.42 and compared with optical stereo DIC measurements on the outer, visible surface of the structure. The shock tube environment introduces temperature and density gradients in the gas through which the structure was imaged, resulting in spatial and temporal index of refraction variations. These variations cause bias errors in optical DIC measurements due to beam-steering but have minimal influence on x-ray DIC measurements. These results demonstrate the utility of time-resolved x-ray DIC measurements in complicated environments where optical measurements suffer severe errors and/or are precluded by lack of optical access.