Publications
High energy X-ray pinhole imaging at the Z facility
McPherson, Leroy A.; Ampleford, David A.; Coverdale, Christine A.; Argo, J.W.; Owen, Albert C.; Jaramillo, Deanna M.
A new high photon energy (hν > 15 keV) time-integrated pinhole camera (TIPC) has been developed as a diagnostic instrument at the Z facility. This camera employs five pinholes in a linear array for recording five images at once onto an image plate detector. Each pinhole may be independently filtered to yield five different spectral responses. The pinhole array is fabricated from a 1-cm thick tungsten block and is available with either straight pinholes or conical pinholes. Each pinhole within the array block is 250 μm in diameter. The five pinholes are splayed with respect to each other such that they point to the same location in space, and hence present the same view of the radiation source at the Z facility. The fielding distance from the radiation source is 66 cm and the nominal image magnification is 0.374. Initial experimental results from TIPC are shown to illustrate the performance of the camera.