Publications

Publications / Conference

Determination of a minimum soiling level to affect photovoltaic devices

Burton, Patrick D.; King, Bruce H.

Soil accumulation on photovoltaic (PV) modules presents a challenge to long-term performance prediction and lifetime estimates due to the inherent difficulty in quantifying small changes over an extended period. Low mass loadings of soil are a common occurrence, but remain difficult to quantify. In order to more accurately describe the specific effects of sparse soil films on PV systems, we have expanded upon an earlier technique to measure the optical losses due to an artificially applied obscurant film. A synthetic soil analogue consisting of AZ road dust and soot in acetonitrile carrier solvent was sprayed onto glass coupons at very brief intervals with a high volume, low pressure pneumatic sprayer. Light transmission through the grime film was evaluated using a QE test stand and UV/vis spectroscopy. A 0.1 g/m2 grime loading was determined to be the limit of mass measurement sensitivity, which is similar to some reports of daily soil accumulation. Predictable, linear decreases in transmission were observed for samples with a mass loading between 0.1 and 0.5 g/m2. Reflectance measurements provided the best means of easily distinguishing this sample from a reference.