Design of a 7-MV Linear Transformer Driver (LTD) for down-hole flash x-ray radiography

Leckbee, Joshua L.; Oliver, Bryan V.

Pulsed power driven flash x-ray radiography is a valuable diagnostic for subcritical experiments at the Nevada Test Site. The existing dual-axis Cygnus system produces images using a 2.25 MV electron beam diode to produce intense x-rays from a small source. Future hydrodynamic experiments will likely use objects with higher areal mass, requiring increased x-ray dose and higher voltages while maintaining small source spot size. A linear transformer driver (LTD) is a compact pulsed power technology with applications ranging from pulsed power flash x-ray radiography to high current Z-pinch accelerators. This report describes the design of a 7-MV dual-axis system that occupies the same lab space as the Cygnus accelerators. The work builds on a design proposed in a previous report [1]. This new design provides increased diode voltage from a lower impedance accelerator to improve coupling to low impedance diodes such as the self magnetic pinch (SMP) diode. The design also improves the predicted reliability by operating at a lower charge voltage and removing components that have proven vulnerable to failure. Simulations of the new design and experimental results of the 1-MV prototype are presented.