Phipps, G.S.; Phipps, G.S.; Sweatt, W.C.; Kemme, S.A.

A figure of merit for optimization of a complete Stokes polarimeter based on its measurement matrix is described from the standpoint of singular value decomposition and analysis of variance. It is applied to optimize a system featuring a rotatable retarder and fixed polarizer, and to study the effects of non-ideal retarder properties. A retardance of 132{degree} (approximately three-eighths wave) and retarder orientation angles of {+-}51.7{degree} and {+-}15.1{degree} are favorable when four measurements are used. An achromatic, form-birefringent retarder for the 3--5 {micro}m spectral region has been fabricated and characterized. The effects of non-idealities in the form-birefringent retarder are moderate, and performance superior to that of a quarter-wave plate is expected.