Publications

Publications / SAND Report

Big Wheel Farm: Farmland Scour Reduction

Olson, Sterling S.; Chartrand, Chris C.; Roberts, Jesse D.

Flood irrigation benefits from low infrastructure costs and maintenance but the scour near the weirs can cause channeling of the flow preventing the water from evenly dispersing across the field. Using flow obstructions in front of the weir could reduce be a low cost solution to reduce the scour. The mitigation strategy was to virtually simulate the effects of various geometric changes to the morphology (e.g. holes and bumps) in front of the weir as a means to diffuse the high intensity flow coming from the gate. After running a parametric study for the dimensions of the shapes that included a Gaussian, semi-circle, and rectangle; a Gaussian-hole in front of the gates showed the most promise to reduce farm field shear-stresses with the added benefit of being easy to construct and implement in practice. Further the simulations showed that the closer the Gaussian-hole could be placed to the gate the sooner the high shear stress could be reduced. To realize the most benefit from this mitigation strategy, it was determined that the maximum depth of the Gaussian-hole should be 0.5 m. The width of the hole in the flow direction and the length of the Gaussian-hole normal to the flow should be 0.5 m and 3 m respectively as measured by the full width at half maximum.