Publications
Benchmarking RADTRAN loss of shielding model for a SNF cask
Boyd, Adam M.; Worthy, Danielle K.; Osborn, Douglas M.; Weiner, Ruth F.
The RADTRAN Loss of Shielding (LOS) Model was benchmarked using MicroShield 6.20®. This analysis considers an intact spent fuel truck cask as well as a set of damaged truck casks. Ratios of dose rates are calculated for casks with a loss of lead shielding to those of intact casks, and are then compared to ratios generated by the LOS model. LOS Model results were considered verified if two main constraints were satisfied. First, the dose rate profiles for both the LOS and MicroShield 6.20® calculations must have the same general shape and behavior. Additionally, the largest factor difference between any two points of the dose rate profiles may not exceed an order of magnitude. Reasonable agreement is shown for large-fraction LOS scenarios; however the differences in results are not satisfactory for cases with small fractions of slump.