Publications
Advances in high intensity e-beam diode development for flash X-ray radiography
Oliver, Bryan V.; Hahn, K.; Johnston, Mark D.; Portillo, Salvador
Recent experiments at Sandia National Laboratories have demonstrated an electron beam diode X-ray source capable of producing > 350 rad at one meter with 1.7 mm FWHM X-ray source distribution, with a 50 ns pulse-width and X-ray photon endpoint energy spectrum in the 6-7 MeV range. The diode operates at current densities of ≈ 1 MA/cm2. The intense electron beam rapidly (≈ 5 ns) heats the X-ray conversion anode/target, liberating material in the form of low density ion emission early in the pulse and high density plasma later. This environment gives rise to beam/plasma collective effects which dominate the diode and beam characteristics, affecting the radiation properties (dose and spot-size). A review of the diode operation, the measured source characteristics and the simulation methods and diagnostics used to guide its optimization is given.