Publications

Publications / Report

A review of Plutonium (Pu) combustion releases in air for inhalation hazard evaluation

Gelbard, Fred G.; Gelbard, Fred G.; Murata, Kenneth K.; McClellan, Yvonne M.

Experimental data are compiled and reviewed for aerosol particle releases due to combustion in air of Plutonium (Pu). The aerosol release fraction (ARF), which is the mass of Pu aerosolized, divided by the mass of Pu oxidized, is dependent on whether the oxidizing Pu sample is static (i.e. stationary) or dynamic (i.e. falling in air). ARF data are compiled for sample masses ranging from 30 mg to 1770 g, oxidizing temperatures varying from 113 C to {approx}1000 C, and air flow rates varying from 0.05 m/s to 5.25 m/s. The measured ARFs range over five orders of magnitude. The maximum observed static ARF is 2.4 x 10{sup -3}, and this is the recommended ARF for safety studies of static Pu combustion.