Hypersonic Wind Tunnel

Technical Characteristics

  • Blowdown to vacuum
  • M = 5, 8, 14
  • Re = 0.2 – 10 x 106/ft
  • Run times: ~45 sec at 45 minute intervals
  • Gases:
    • air at Mach 5
    • N2 at Mach 8 and 14
  • 18″ diameter test section
  • 4″ – 5″ maximum diameter model size
  • Stagnation temperature to 2500°R