DICE Experiments
Experiments Conducted at the DICE Facility
3″ Compressed Gas Driven Gun
- Compressed gas driven
- 76mm bore diameter
- 240-540 gm projectile mass
- 80-450 meters/second velocity
- 0.3-6 GPA (60kbar)
- VISAR, Line ORVIS, X-ray diffraction
- Sample Soft capture
- X-ray diffraction
VELOCE 3.5MA Isentropic Driver
- 10mm-30mm Panels
- 8-26mm sample diameter
- 420-540ns rise times
- 5-14GPA (140kbar)
- VISAR
- Sample Pre-Heating
- Sample Soft capture
THOR Pulsed Power Machine
- 6mm-20mm Panels
- 5-26mm sample diameter
- 260-850ns rise times
- 1-40GPA (panel size dependent)
- VISAR, PDV
- Sample Pre-Heating
- Sample Soft capture
Target Fabrication Lab
- Class 100 clean room
- High precision optical measurement systems
- High precision weight measurement systems
- Precision sample preparation
- Ultra sonic measurements